• Title/Summary/Keyword: Enamel roughness

Search Result 39, Processing Time 0.023 seconds

Comparison of Shear Bonding Strength of Laminate Veneer by Lithium Disilicate Ceramics and Surface Treatment Methods (리튬디실리케이트 세라믹과 표면처리방법에 따른 라미네이트 베니어의 전단결합강도 비교)

  • Park, Sang-Joon;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.177-185
    • /
    • 2019
  • Purpose: This study was to investigate the effect of three different surface treatments on the shear bond strength of lithium disilicate ceramics to enamel. Methods: Totally 60 lithium disilicate ceramic disc specimens were fabricated with IPS e.max press (Ivoclar Vivadent, Schaan, Liechtenstein) and Mazic Claro (Vericom, Korea). 30 specimens in each lithium disilicate ceramic were assigned to 3 groups of the each following surface treatment: 1) $50{\mu}m$ airborne particle abrasion+silane, 2) 9.5% hydroflouric acid etching (HF)+silane, 3) $50{\mu}m$ airborne particle abrasion+9.5% HF+silane. Lithium disilicate ceramic surfaces after surface treatments were AFM examined. The shear bond strength was measured in a universal testing machine at 0.5mm/min crosshead speed. All data were analyzed using a two-way ANOVA and Tukey's test(${\alpha}=0.05$). Results: The mean surface roughness of lithium disilicate ceramics ranged from $0.178{\mu}m$ to $0.441{\mu}m$. The mean shear bond strengths ranged from $23.81{\pm}2.78MPa$ to $33.99{\pm}4.85MPa$. Conclusion: 1. Mazic Claro showed higher shear bond strength than IPS e.max press at 3 different surface treatments, and no statistically significant was observed. 2. The shear bond strength of IPS e.max press was strongly enhanced as surface treated with $50{\mu}m$ airborne particle abrasion and 9.5% hydroflouric acid etching. And there was no statistical significance at the shear bond strength of Mazic Claro with surface treatments.

A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION (가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구)

  • Shin, Dong-Hoon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF

The effect of acidic drinks on the surface of tooth-colored restorative materials (산성음료가 치아색 수복재의 표면에 미치는 영향)

  • Bang, Seok-Yun;Kim, Eun-Jung;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.469-481
    • /
    • 2006
  • Among the etiologic factors of enamel corrosion, daily intake has been considered with a profound interest, especially the intake of acidic drinks. It is thought that the rapid consumption of acidic drinks will not only results in the affection to the teeth but also to the surface of the tooth-colored restorative materials. Therefore, the puopose of this study is to examine the alterations occurred in the surface of the tooth-colored materials according to the exposed time, with 3 most common acidic drinks in contact with daily life. Resin-modified glass-ionomer, polyacid-modified composite resin, composite resin were immersed on 0.9% NaCl, Coke, orange juice, sports beverages as 4 groups in each. The surface hardness and the surface roughness of specimens were measured with following methods: before immersion, 1 day after immersion, 1-,2-,3-,4- weeks after immersion. Results were as follows. 1. Tooth-colored restorative materials, with the exception of composite resin, showed statistically significant changes in surface hardness and roughness when immersed on acidic drinks(p<0.05). 2. The degree of change in surface hardness and roughness occurred as follows, in order of severity from greatest to least resin-modified glass-ionomer, polyacid-modified composite resin, composite resin 3. Sports beverages resulted in greater alterations to surfaces than Coke and orange juice. 4. In the SEM image of the groups immersed in acidic drinks, resin-modified glass-ionomer and polyacid-modified composite resin showed loss of filer. Severe cracks were observed, especially on the resin-modified glass-ionomer.

  • PDF

Effect of dentin surface roughness on the shear bond strength of resin bonded restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Poursoltan, Sajjad
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.224-228
    • /
    • 2016
  • PURPOSE. This study aimed to investigate whether dentin surface preparation with diamond rotary instruments of different grit sizes affects the shear bond strength of resin-bonded restorations. MATERIALS AND METHODS. The buccal enamel of 60 maxillary central incisors was removed with a low speed diamond saw and wet ground with silicon carbide papers. The polished surfaces of the teeth were prepared with four groups of rotary diamond burs with super-coarse (SC), coarse (C), medium (M), and fine (F) grit sizes. Following surface preparation, 60 restorations were casted with nickel-chromium alloy and bonded with Panavia cement. To assess the shear bond strength, the samples were mounted on a universal testing machine and an axial load was applied along the cement-restoration interface at the crosshead speed of 0.5 mm/min. The acquired data was analyzed with one way ANOVA and Tukey post hoc test (${\alpha}=.05$). RESULTS. The $mean{\pm}SD$ shear bond strengths (in MPa) of the study groups were $17.75{\pm}1.41$ for SC, $13.82{\pm}1.13$ for C, $10.40{\pm}1.45$ for M, and $7.13{\pm}1.18$ for F. Statistical analysis revealed the significant difference among the study groups such that the value for group SC was significantly higher than that for group F (P<.001). CONCLUSION. Dentin surface roughness created by diamond burs of different grit sizes considerably influences the shear bond strength of resin bonded restorations.

Surface Characteristics of Ground and Post-Sintered Zirconia (지르코니아의 소결 후 특성)

  • Kim, Min-Jeong;Kim, Im-Sun;Choi, Byung-Hwan;Kim, Won-Gi
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.157-163
    • /
    • 2016
  • Purpose: It is to compare and evaluate the change of the wear rate and phase variation of the Zirconia before and after the sintering after the grinding by a high speed equipment manufactured for the Zirconia. Methods: The specimen of the sintered Zirconia was manufactured as size of $15mm{\times}15mm{\times}2mm$. The grinding has been applied to each of all pieces of each test groups for a minute fit for each condition at same speed of 50,000 rpm by a diamond bur at high speed handpiece with injection of the air and water. For the observation of the surface before and after the sintering of the each test piece, the cross section of it was observed as 100 magnification by a scanning electron microscope after it was coated by PT, and the diffraction analysis was performed by XDR to compare the crystal phase of the Zirconia. The average surface roughness value of all specimens were evaluated. The wear test was performed at room temperature by applying a load of 1kg for 120,000 cycles for the chewing period 6 months. Wear was analyzed for the enamel cusps by measurement of the vertical substance loss with a laser scanner. Conclusion: The phase variation from the tetragonal phase to the monoclinic phase was confirmed in the test group of the pre-sintered Zirconia after the grinding, and the value of the surface roughness and the wear rate was increased in experimental group.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Biological Applications of White Light Scanning Interferometry (백색광 주사간섭계의 생물학적 응용)

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.41 no.4
    • /
    • pp.223-228
    • /
    • 2011
  • White light scanning interferometry has been employed to analyze surface features of diverse specimens. Long established in the field of materials engineering, the technique provides quantitative three-dimensional data as well as qualitative morphological images. It uses white light that is split and reflected from a reference mirror and an object. Merged together, the light generates interference patterns representing topographical contours of the object surface. The amplitude of the z-axis data is differentiated by gray scale. The technique allows the rapid, noncontact, and wide-field measurements for morphometry of biological specimens including chondrocytes, tooth enamel, and plant leaves. Quantification of the dimension of surface structures such as width, length, and elevation angle could be achievable by white light scanning interferometry. The light reflection from plant leaves has been assumed to be sufficient for the technique. Without special specimen preparations like conductive metal coating, the technique can be increasingly used for quantitative three-dimensional surface measurements of biological specimens.

AN EXPERIMENTAL STUDY ON ADHESION PATTERN, ADHESION STRENGTH AND FRACTURE PATTERN OF THE ADHESIVE CAST GOLD INLAY (접착형 구조 금 인레이의 접착 형태, 강도 및 파절 양태에 관한 실험적 연구)

  • Han, Seoung-Ryul;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.64-72
    • /
    • 1994
  • Zinc Phosphate Cement hand been used for about more than 100 years in luting of cast gold inlay. But many scientists had been trying to develop the new form of luting agent because the ZPC hand shown the lack of adhesiveness on the tooth structure and the toxicity to the pulp tissue. Recently many researches about the surface treatment of the cast body are being done to increase the adhesion of cement to it. The conventional Class I gold inlays were fabricated in the 20 permanent molars. After the internal surface of the cast body was sandblasted with $Al_2O_3$ particles and was tin-plated, the inlays were cemented with adhesive cement [G I cement and resin cement(Super-Bond & $Panavia_{EX}$)] and the evaluation on the adhesion pattern, adhesive strength and the fracture pattern of the adhesive cast gold inlay was compared to that of the cast gold inlay cemented conventionally with ZPC. The results were as follows : 1. The surface roughness of the cast body was increased significantly after sandblasting with the $Al_2O_3$ particles and the tin oxide layer, which was consisted of round particles, came into being. 2. The bond strength was in the order of Super-Bond, ZPC, Fuji I, $Panavia_{EX}$ group. The group cemented with Super-Bond showed statistically greater strength than the other groups(p<0.05). 3. The group cemented with ZPC was fallen apart by principal adhesion failure and that with Fuji I was by complete adhesion failure. But the group with Super-Bond showed pricncipal cohesive failure pattern and in the group with $Panavia_{EX}$, complete cohesive fracture pattern was shown and small protion of tooth structure was fractured out with cast body and the fractured surface showed the figure just as the enamel prism. 4. Various gaps were shown at the pulpal side regardless of little gap at the side walls of the cavity in all groups. Only the Super-Bond was attached to the tooth structure and the other cements were detached from both the tooth and the cast body.

  • PDF

Experimental brush wear pattern and cariostatic effect of Biscover (Biscover의 잇솔질에 따른 마모양상과 항우식 효과)

  • Oh, Eun-Ju;Park, Song-Soo;Jang, Mun-Ju;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.214-222
    • /
    • 2008
  • Objective: The aim of this study was to investigate the experimental brush wear pattern of a light cured surface sealant, Biscover (Bisco, Schaumburg, IL), and to evaluate its cariostatic effect. Methods: Caries-free human premolars were used for the Biscover coating group (n = 90) and the control group (n = 10). The Biscover coating group was randomly assigned to nine subgroups of 10 each and the control group was assigned to two subgroups of 5 each according to the number of brushing strokes. An experimental 3-body wear test was conducted under different strokes of wear test. Tooth-brushing was accomplished with movement of each brush head set at a frequency of 100 rpm under a force of 1.5N, Surface roughness was tested before, and after Biscover coating, and after brushing. Then, each of the 10 teeth of both groups were placed in artificial caries inducing solution for 7 days. All tooth surfaces were assessed using scanning electron microscopy. Results: Biscover coated surfaces showed a smoother texture than enamel surfaces. The roughness was increased after experimental brushing and after 10,800 brushing strokes, the whole layer of Biscover wore out. However, teeth in the Biscover coating group had a cariostatic effect in cariogenic conditions. Conclusions: We suggest that white lesions in orthodontic patients can be suppressed by topical applications of Biscover.