• 제목/요약/키워드: Enamel margin

검색결과 70건 처리시간 0.018초

IRM 임시수복이 상아질 접착제의 변연 미세누출에 미치는 영향 (THE INFLUENCE OF IRM TEMPORARY RESTORATIONS ON MARGINAL MICROLEAKAGE OF DENTIN ADHESIVES)

  • 조영곤;김현경;이영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2003
  • This study investigated the influence of IRM on marginal microleakage of 5th generation adhesives. Class V cavities with gingival margins in dentin were prepared on both buccal and lingual surfaces of 60 extract-ed human molar teeth. Prepared teeth were randomly divided into six groups. Group 1 and 4 received no temporary restoration with IRM. Group 2 and 5 were covered with IRM mixed at P/L ratio(10g/1g). Group 3 and 6 were covered with IRM mixed at P/L ratio(10g/2g). The temporary restorations were removed mechanically with an ultrasonic scaler after one-week storage in distilled water. The cavities were restored using one of two adhesives and composites ; Single Bond/Filtek Z 250(Croup 1, 2 and 3), UniFil Bond/UniFil F(Group 4, 5 and 6). Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles(between $5^{\circ}C{\;}and{\;}55^{\circ}C$) and immersed in 2 % methylene blue for dye penetration testing. The results were analysed using Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked test at a significance level of 0.05. The results of this study were as follows 1. Ranking of mean microleakage scores at the enamel margins was Group 10.05) 4. At the dentin margins, the microleakage of the group not pretreated with IRM was lower than that of the group pretreated with IRM. And the microleakage of UniFil Bond was lower than that of Single Bond. 5. Compared with microleakages between the enamel and dentin margins of each groups, Group 1, 2, 3, 4, 5 and 6 at dentin margin were higher microleakage than those at enamel margin. There were significant difference between enamel and dentin microleakage of Group 2 and 3(p<0.05).

수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구 (MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS)

  • 최상철;박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

5급 와동의 수복에 있어서 수종의 compomer의 미세 변연 누출에 관한 연구 (MICROLEAKAGE OF CLASS V COMPOMER RESTORATIONS)

  • 유현미;박동성;오태석
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.41-45
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of compomers. In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of thirty extracted human premolars and molars on cementum cervical margin. The experimental teeth were randomly divided into five groups of six samples (12 surfaces) each, Group 1 : Dyract AP, Group 2 : F2000 compomer(non-etch), Group 3 : F2000 compomer(etch), Group 4 : Elan, Group 5 : Compoglass. The bonding agents and compomer were applied for each group following the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 30 teeth were placed 1% methylene blue dye for 24 hours then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of the restoration with a low speed diamond saw. The dye penetration on each of the specimen was observed with a stereomicroscope. The results of study were statistically analyzed using the Student-Newmann-Kaul' s Test. The results were obtained as follows. 1. All compomer restoration systems did not completely prevent marginal leakage. 2. In enamel margin, F2000 compomer(etch) group showed lower leakage value than other systems. Elan and Compoglass groups showed lower leakage value than Dyract AP and F2000 compomer(non-etch) groups (p<0.05). 3. In cementum margin, F2000 compomer(etch) and F2000 compomer (non-etch) groups showed lower leakage value than other systems. Dyract AP and Elan groups showed lower leakage value than Compoglass group (p<0.05).

  • PDF

치근 우식 수복에 사용되는 심미성 수복물의 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF ESTHETIC RESTORATIVE MATERIALS ON ROOT CARIES RESTORATION)

  • 한진순;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.205-213
    • /
    • 1993
  • The purpose of the study was to evaluate the degree of the marginal leakage of esthetic restorative materials on root caries restoration. 120 cavities were prepared to $90^{\circ}$ butt joint on all margins on the crown and root portion, and divided into 4 groups. The four groups of cavity were filled with Amalgam(Dongmuyung Dental Alloy Co., Ltd, KOREA), Silux$^{(R)}$(3M Co., USA)-Scotch Bond 2$^{(R)}$(3M Co., USA), Silux$^{(R)}$-All Bond$^{(R)}$(BISCO USA), and GC Fuji II$^{(R)}$(G-C Co., JAPAN) respectively. The apical margin of the preparation was finished to leave a flash of restorative material. The coronal margin of the preparation was finished not to leave a flash of restorative material. All specimens were sectioned longitudinally with Isomet Low speed saw(Buether Ltd, USA). The degree of dye penetration was evaluated as the parameter of marginal leakage under the stereoscope. The results were as follows. 1. At the enamel and dentin/cementum margins, the margin were finished to leave a flash of material showed less marginal leakage than that were finished not to leave a flash of material (P<0.001). 2. The enamel margins showed less marginal leakage than the dentin/cementum margins(P<0.001). 3. There was no significant difference in the degree of the marginal leakage between Silux$^{(R)}$-Scotch Bond 2$^{(R)}$ group and Silux$^{(R)}$-All Bond$^{(R)}$ group.

  • PDF

Primer Bonding agent, 복합레진 내의 볼소의 법랑질에 대한 항우식 작용 (THE ANTICARIOGENIC EFFECT OF F IN PRIMER, BONDING AGENT AND COMPOSITE RESIN IN THE CAVOSURFACE ENAMEDL AREA)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.635-641
    • /
    • 1996
  • This study was designed to evaluate the anti cariogenic effect of F in primers, bonding agents, composite resins or glass ionomer cements in enamel. Twenty-five extracted teeth were selected and a cavity was prepared on either the buccal or the lingual surface of each tooth. After pumicing and etching, the samples were divided into 5 groups. In group A, the samples were primed, bonded and filled with ART bond and Brilliant Enamel (Coltene, Switzerland). Group B composed of Optibond and Herculited XRV (Kerr, USA), group C composed of Syntac and Tetric(Vivadent, Lichtenstein), and group D composed of Scotch-bond Multipurpose and Z 100 (3M, YSA). In group E, the samples were filled with glass ionomer cement (Fuji II LC, Japan), All surfaces except the 2mm beyond the cavosurface margin of the sample were protected, and samples were then put into an acid buffer for 3 days to develop the initial caries. The samples were then sectioned through the filling body into thin wafers and then examined with a polarizing microscope under water imbibition. The fluoride in primer, bonding agent, or composite filling material did not prevent the initial caries in the enamel area adjacent to the filling body whereas the fluoride in the glass ionomer did prevent the initial stage caries.

  • PDF

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF

복합레진 수복시 복합용기 및 단일용기 상아질 접착제의 미세변연누출에 관한 연구 (MICROLEAKAGE OF CURRENT DENTIN BONDING SYSTEMS)

  • 류주희;박동성;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.55-66
    • /
    • 1999
  • The purpose of this study was to evaluate the microleakage of 5 current dentin bonding systems which are composed of 2 multi-bottle systems(Scotchbond Multi-Purpose, All Bond2) and 3 one-bottle systems(Single bond, One-Step, Prime & Bond). In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of sixty extracted human premolars and molars on cementum margin. The experimental teeth were randomly divided into six groups of 10 samples (20 surfaces) each, Group 1 : Scotchbond Multi-Purpose ; Group 2 : All Bond 2 ; Group 3 : Single Bond ; Group 4 : One-Step ; Group 5 : Prime & Bond ; Group 6 : no bonding agent(control). The bonding agent and composite resin were applied for each group following the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% Methylene blue dye for 24 hours, then rinsed with tab water. The specimen were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen were then observed with a stereomicroscope at ${\times}20$. The results of study were statistically analyzed using the Student-Newmann-Keul's Methods and the Mann-Whitney Rank Sum Test. The resin/dentin interfaces were examined under Scanning Electron Microscopy. The results of this study were as follows. 1. None of the dentin bonding systems used in this study showed significant difference in leakage values at both the enamel and the dentin margins (P>0.05). 2. In all groups except the control, leakage value seen at the enamel margin was significantly lower than that seen at the dentin margin (P<0.05). 3. Compared to the control group, all the groups treated with dentin bonding systems showed significantly lower leakage value at both enamel and dentin margins (P<0.05). 4. In the SEM view, gaps were observed in the composite resin / dentin interface in group 6 where no dentin bonding agent was used, and in all the other groups (group 1, 2, 3, 4, 5) composite resin, hybrid layer, and dentin were seen to be closely adhering to each other where there were no leakages. Well-developed resin tags 3~100${\mu}m$ in length infiltrated dentinal tubules past the hybrid layer and a hybrid layer 1~5${\mu}m$ thick had developed between the dentinal surface and the composite resin surface.

  • PDF

다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교 (MICROLEAKAGE OF 2-STEP ADHESIVE SYSTEMS IN DIAMOND-PREPARED CAVITY)

  • 이명구;조권환;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.437-444
    • /
    • 2007
  • 이 연구는 거친 입자와 미세한 입자의 다이아몬드 포인트로 형성한 5급 와동에서 서로 다른 2단계 접착시스템 사용시 법랑질과 상아질 변연에서의 미세누출 차이를 상호 비교하기 위하여 시행하였다. 40개의 발거한 대구치의 협면 치경부에 각각 $106-205\;{\mu}m$의 거친 다이아몬드 포인트 (EX-41)와 $53-63\;{\mu}m$의 미세한 다이아몬드 포인트 (TF-21F)를 이용하여 20개씩 5급 와동을 형성한 후 사용된 접착시스템과 복합레진에 따라 다음과 같이 4개의 군으로 분류하였다; 1군은 EX-41 포인트로 형성한 와동에 Single Bond와 Z 250을 사용한 군, 2군은 TF-21F 포인트로 형성한 와동에 Single Bond와 Z 250을 사용한 군, 3군은 EX-41 포인트로 형성한 와동에 Clearfil SE Bond와 Clearfil AP-X를 사용한 군, 4군은 TF-21F 포인트로 형성한 와동에 Clearfil SE Bond와 Clearfil AP-X를 사용한 군으로 분류하였다. 각 군은 $5^{\circ}C$$55^{\circ}C$의 증류수에서 500회 열 순환한 후 2% methylene blue용액에 1일 동안 침적하였다. 각 군의 치아를 협설로 절단하여 광학 입체현미경 하에서 법랑질과 상아질 변연에서의 색소침투 정도를 관찰하여 미세누출 점수를 평가하고, 각 군 간의 유의성을 검정하여 다음과 같은 결과를 얻었다. 이 연구를 종합하면, 5급 와동에서 Single Bond는 이 연구에 사용한 다이아몬드 포인트의 종류에 따른 변연 미세누출 차이를 보이지 않았으나 Clearfil SE Bond는 거친 다이아몬드 포인트 보다는 미세한 다이아몬드 포인트를 사용하는 것이 법랑질과 상아질 변연 모두에서 낮은 미세누출을 보였다.

제 2급 와동에서 구치부 복합레진의 미세변연누출에 관한 연구 (MICROLEAKAGE OF POSTERIOR PACKABLE COMPOSITE RESIN hi THE GINGIVAL MARGINS OF CLASS II CAVITIES)

  • 최수진;김미자;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.249-256
    • /
    • 2002
  • The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).

5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출 (The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin)

  • 최유석;정순정;정문진;안용순;박선녀;임도선
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.330-338
    • /
    • 2013
  • 5급 와동에서 상아질 접착제와 레진의 종류에 따른 미세누출을 알아보고자 64개의 건전한 상 하악 소구치 및 대구치에 5급 와동을 형성하였다. 형성된 와동에 4종의 상아질 접착제를 각각 적용하고 2종류의 복합레진을 수복하여 법랑질과 상아질 변연부 색소침투 정도를 실체현미경하에서 23배율로 관찰하여 미세누출 점수를 기록한 후 각 군 간의 유의성을 검정하였다. 연구 결과, 5급 와동 수복 시 상아질 접착제와 레진의 종류에 따른 미세누출은 통계적으로 유의하지 않았다. 그러나 복합레진 Filtek Z350XT Universal 적용 시 1단계 자가부식 접착제 Adaper Easy Bond에서 미세누출이 낮게 나타났고, 유동성레진 Filtek Z350XT Flowable 적용 시 3단계 전부식 접착제 Adaper Scotchbond Multi-Purpose, 2단계 전부식 접착제 Adaper Single Bond 2에서 미세누출이 낮게 나타났다. 따라서 복합레진 및 상아질 접착제의 선택적 적용이 가능하며 특히, 1단계 자가부식 상아질 접착제 적용 시 조작의 편이성과 시술시간의 단축에 유리할 것으로 생각된다.