In Orbit Radiometric Calibration Tests of COMS MI Infrared Channels

  • Jin, Kyoung-Wook;Seo, Seok-Bae
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.369-377
    • /
    • 2011
  • Since well-calibrated satellite data is critical for their applications, calibration and validation of COMS science data was one of the key activities during the IOT. COMS MI radiometric calibration process was divided into two phases according to the out-gassing of the sensor: calibrations of the visible (VI) and infrared (IR) channels. Different from the VIS calibration, the calibration steps for the IR channels followed additional processes to secure their radiometric performances. Primary calibration steps of the IR were scan mirror emissivity correction, midnight effect compensation, slope averaging and 1/f noise compensation after a nominal calibration. First, the scan mirror emissivity correction was conducted to compensate the variability of the scan mirror emissivity driven by the coating material on the scan mirror. Second, the midnight effect correction was performed to remove unreasonable high spikes of the slope values caused by the excessive radiative sources during the local midnight. After these steps, the residual (difference between the previous slope and the given slope) was filtered by a smoothing routine to eliminate the remnant random noises. The 1/f noise compensation was also carried out to filter out the lower frequency noises caused from the electronics in the Imager. With through calibration processes during the entire IOT period, the calibrated IR data showed excellent performances.

적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구 (A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography)

  • 김경석;정현철;박찬주;김동수;정덕운;장호섭
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.421-426
    • /
    • 2009
  • 열화상 카메라와 대상물의 측정 위치에 따른 방사각도에 따라 방사율은 달라지게 된다. 이로 인해 열화상 시스템을 이용한 온도 측정시 나타나는 온도 분포는 절대적 온도로 볼 수 없다. 대상체의 실제 표면 온도가 일정하더라도 열화상 카메라로 측정된 온도는 방사율 값에 따라 오차를 가지게 된다. 본 논문에서는 동일 온도로 가열된 원통 형태를 가지는 대상체와 평면 형태를 가지는 대상체의 온도를 열화상 카메라를 이용하여 측정하였다. 측정된 표면 온도값을 통하여 화각에 의한 방사율 보정표와 방사각도의 영향에 의한 반사율 보정식을 구하였으며 이를 바탕으로 측정 온도의 오차보정을 수행하였다. 그리고 방사 각도와 화각에 따른 온도 영향을 원자력 배관의 결함 검출에 적용하여 더욱 신뢰성 있는 표면 온도값을 획득하였다.

반구면경을 이용한 스펙트럼 방사율 측정법 (Measurement Method of the Spectral Emissivity by Using Hemispherical Mirror)

  • 배신철;오기수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.789-795
    • /
    • 2003
  • It is studied that the measuring method of the spectral emissivity by using hemispherical mirror with an inclined observation hole. The in-service calibration method of mirror reflectivity is also dealed with. It is possible to apply this method on measuring emissivity of conductor or non-conductor.

적외선 카메라를 이용한 표면온도측정의 왜곡 보정 (Distortion Correction of Surface Temperature Measurement Using an Infrared Camera)

  • 이성민;김익현;이종국;변영환;박기수
    • 한국항공우주학회지
    • /
    • 제44권7호
    • /
    • pp.545-551
    • /
    • 2016
  • 적외선 열화상 방식을 사용하여 초음속 풍동모델 표면온도를 측정하였다. 표면온도를 정량적으로 파악하기 위해 적외선 카메라 감지신호의 흑체 보정, 카메라와 렌즈의 불완전한 평형 등으로 야기되는 왜곡 보정, 그리고 모델표면 시야각에 따른 방사율 보정을 수행하였다. 본 연구를 통해 적외선 카메라를 이용한 표면온도측정의 왜곡보정 기술을 확보하였으며, 공력특성 실험을 통해 통상적으로 사용되는 이차원 시험모델 사용시 정성적일 뿐만 아니라 정량적인 계측을 위해서는 왜곡보정이 고려되어야 함을 입증하였다.

퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정 (Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer)

  • 전상호;유남준;조재흥;박철웅;박승남;이근우
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.400-407
    • /
    • 2008
  • 퓨리에 변환 적외선 분광기(FT-IR)를 이용한 물질의 적외선 분광 복사율 측정 장치를 구축하고 이 장치의 성능을 평가하였다. 본 장치는 기준 흑체, 시료 가열로, 광학계, FT-IR로 구성되어 있으며, 측정 온도 및 파장 영역은 $200^{\circ}C{\sim}500^{\circ}C$$3.5{\mu}m{\sim}20{\mu}m$ 이다. 기준 흑체의 유효 복사율은 0.9993 이상으로 거의 1에 가까운 값을 나타내고 있었으며, 흑체의 분광 복사율에 대한 합성 상대 불확도는 0.69% 이하이다. $300^{\circ}C$에서 불투명한 알루미나, 흑연, 양극 처리된 알루미늄 시료의 수직 분광 복사율과, 금속(IMS200)의 표면 거칠기에 따른 복사율을 측정하였다. 금속(IMS200)의 표면 거칠기에 따른 복사율 변화는 거칠기가 증가할수록 증가하였다.

Investigation of NESDIS's Calibration Algorithm of the Imagers for IR Channels on GOES-12

  • Chang, Ki-Ho;Oh, Tae-Hyung;Ahn, Myung-Hwan;Cho, Nam-Seo;Oh, Sung-Nam
    • 대한원격탐사학회지
    • /
    • 제23권1호
    • /
    • pp.55-58
    • /
    • 2007
  • The prototype radiometric calibration algorithm of the imagers for IR channels has been developed according to the Weinreb's method. Applying the algorithm to the GOES-12 count data, we have shown that the calibration coefficients (slope and intercept) evaluated by the algorithm gives good agreement with the NESDIS's ones, and that the scanning error due to the scan mirror emissivity and stripe error are almost eliminated by the East/West angle dependent scan-mirror correction and the respective calculation of intercept for each North/South scan line, respectively.

SPACE-BORNE MICROWAVE RADIOMETER CALIBRATION/VALIDATION IN CHINA

  • Zhenzhan, Wang;Yun, Li;Shixiang, Tan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.598-603
    • /
    • 2002
  • We summarize the activities concerning to the space-borne microwave radiometer (RAD) calibration and validation (Cal/Val) in China. It is important to know in advance the brightness temperature of a given sea surface before external calibrating RAD due to its special characteristic of system. In the paper, we analyse some modeling results on sea surface emissivity and atmospheric transmissivity at different frequencies, and compare the calculated brightness temperatures with those measurements from some air-borne microwave radiometers. We also introduced the whole contents on RAD Val and developed two methods of retrieving sea surface winds. We compared the retrievals of wind speeds to those from NDBC buoys. At last, we introduce some plans of Cal/Val for testing our RAD.

  • PDF

적외선 검출기 검보정을 위한 대구경흑체 설계, 제작 및 검증 (Full Aperture Black Body Design, Fabrication and Validation for Infrared Detector Calibration)

  • 조혁진;서희준;김근식;박성욱;문귀원
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.40-45
    • /
    • 2013
  • 적외선 영상을 획득하는 인공위성의 적외선 검출기는 임무 궤도에서 정확한 성능을 보장받기 위해 발사 전 지상에서 흑체를 이용한 검보정 환경시험을 거쳐야 한다. 적외선 탑 재체의 검보정 기준이 되는 대구경흑체는 궤도환경 지상시험을 위해 진공환경에 적합한 재질로 구성되어야 하며, $-40^{\circ}C$에서 $+40^{\circ}C$까지의 온도 범위에서 중심 80 %의 영역에 대해 $2^{\circ}C$ 이하의 표면 온도 균일도와 0.95 이상의 방사율을 가져야 한다. 열유동해석 결과로 도출된 대구경흑체는 $1m{\times}1m{\times}8mm$의 크기의 구리판에 방사율을 높이기 위한 알루미늄 하니콤 코아를 부착하고, 블랙페인트를 도포하여 제작되었으며, 온도 조절을 위해 뒷면에는 질소가스 흐름을 위한 구리튜브가 용접되었다. 한국항공우주연구원의 광학열 진공챔버에서 수행된 대구경흑체 검증시험에서 20개의 저항온도센서와 적외선카메라를 이용하여 표면 온도 분포를 측정하여 ${\pm}40^{\circ}C$의 온도 범위에서 약 $1^{\circ}C$의 온도 균일도를 가짐을 확인하였다. 표면방사율은 대기압, $40^{\circ}C$에서 0.975로 측정되었다.

영상센서의 비균일 출력특성 교정용 흑체의 열설계 및 궤도 열해석 (On-Board Black Body Thermal Design and On-Orbit Thermal Analysis for Non-Uniformity Correction of Space Imagers)

  • 오현웅;신소민;홍주성;이민규
    • 한국항공우주학회지
    • /
    • 제38권10호
    • /
    • pp.1020-1025
    • /
    • 2010
  • 탑재 교정용 흑체는 우주용 영상센서의 시간경과 및 재 구동에 따른 센서의 특성변화 교정을 통한 영상품질향상을 위해 적용된다. 본 논문에서 제안한 영상센서의 비균일 특성 교정을 위한 흑체 열설계는 저온에서 고온에 이르는 흑체의 온도정보 제공을 위한 흑체 가열용 히터, 흑체 가열 후 잔열 수송 및 심해우주로의 열 방출을 위한 히트파이프와 방열판 그리고 비교정임무 수행동안 흑체가 특정온도를 유지하며 원하는 시점에서 언제든지 교정임무 수행이 가능하도록 하는 방열판용 히터로 구성된다. 흑체 열설계에 대한 타당성을 궤도 열해석을 통해 입증하였다.

적외선 열화상 카메라용 캘리브레이션 타겟 개발 (Development of Calibration Target for Infrared Thermal Imaging Camera)

  • 김수언;최만용;박정학;신광용;이의철
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.248-253
    • /
    • 2014
  • 카메라 영상 캘리브레이션은 머신비전과 같은 비전검사기술분야에서 영상으로부터 기하학적 정보를 정확하게 추출하고자 할 때 정확성을 높이는데 필요한 매우 중요한 과정이다. 그러나 기존에 가시광 카메라에 사용되던 캘리브레이션 타겟은 중적외선, 원적외선 열화상 카메라에 적용하기 어렵다. 최근에 적외선 열화상카메라를 이용한 결함측정기술이 많이 사용되면서 적용할 수 있는 캘리브레이션 타겟 개발이 요구되고 있다. 따라서 본고에서는 유한요소 열전달 해석을 이용하여 가시광 카메라와 적외선 열화상카메라 모두에 적용 가능한 캘리브레이션 타겟을 제안하였다. 개발된 캘리브레이션 타겟을 열화상카메라와 가시광 카메라로 촬영하여 비교실험 하였으며, 실험결과 제안된 캘리브레이션 타겟의 효율성을 보여준다.