• Title/Summary/Keyword: Emission method

Search Result 3,468, Processing Time 0.029 seconds

The Estimation of the Energy Consumption and $C0_2$ Emission at the Construction Stage in the Apartment Housing (공동주택 건설단계 공종별 에너지소비량 및 이산화탄소 배출량 산정연구)

  • Kim, Dae-Hee;Kwon, Bo-Min;Choi, Young-Oh;Lee, Kang-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.328-333
    • /
    • 2006
  • A few methodologies have been recently developed to estimate the environmental affect when various materials and components are used in building life cycle. The direct survey method has limitations to analyze the environmental problems because of the limit of survey scope and cost. Therefore, another indirect method has been developed as alternatives. The indirect method is represented as input-output analysis. This paper aimed at analyzing the estimation the environmental affect of building materials and works at building construction, utilizing the input-output analysis as a indirect estimation method. The results suggested that the building works is overally responsible for the energy consumption and $CO_2$ emission. In other words, Over the 80% of the total consumption and $CO_2$ emission are resulted at the building work.

  • PDF

The Evaluation of Internal Leak in Valve for Power Plant Using Acoustic Emission Method (음향방출법에 의한 발전용 밸브 누설평가)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Jun-Shin;Lee, Wook-Ryun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1733-1739
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

An Experimental Study on Determination of Capacity of Catalysts in 2 -Catalyst System (2-촉매 시스템에서의 촉매 용량 결정에 대한 실험적 연구)

  • Ko, Kwang-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 2003
  • There are various method for the LEV(Low Emission Vehicle) regulation, but 2-catalyst system using one catalyst near exhaust manifold and another catalyst underfloor, is the most popular. This system uses the proven catalyst technology and doesn't use energy. But it is difficult to determine capacity of the two catalysts. So an optimization method to determine the capacity has been proposed by other researcher. It uses the fact that emission decreases with capacity increasing, but the decreasing ratio slows down in high capacity range. It means that the emission and capacity of catalyst is exponentially decreasing relation. In this paper this method will be verified with various experiments. And this method was proven to be very useful to determine the capacity of two catalysts system.

  • PDF

Measuring Methods and Their Improvement of Formaldehyde Emission from Wood-Based Panels (목질제품의 포름알데히드방출량 측정방법과 개선방안)

  • Park Byung-Dae;Park Jong Young
    • Journal of the Korea Furniture Society
    • /
    • v.15 no.2
    • /
    • pp.1-17
    • /
    • 2004
  • This paper attempted to review measuring methods of formaldehyde emission from wood-based panel products. Methods included for the discussion were desiccator methods, extraction method, and various chamber methods. First, the procedures and testing conditions of 24-hour desiccator method was critically reviewed, and an improvement of this method was proposed to meet international standards. Two different small chamber methods ($20\ell$ and $1m^3$ chamber methods) were also compared in terms of their advantages and disadvantages. In addition, the regulation levels of formaldehyde emission of wood-based composite panels were compared for different countries. The selection of a reference method of measuring formaldehyde emission of wood panel products should consider the ease of conducting test and cost required. Results should be exchangeable for different methods.

  • PDF

A Study on the Evaluation of Internal Leak in Valve for Nuclear Power Plant Using Acoustic Emission Method (음향방출법에 의한 원자력발전소 밸브내부 누설평가에 관한 연구)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Jun-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.284-289
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

Measurement of Secondary Electron Emission Coefficient on Deposition Time of the Silicon Thin Films (실리콘박막의 증착시간에 따른 감마계수 측정법 개발)

  • Lee, Jung-Hui;Choi, Byoung-Jung;Yang, Sung-Chae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.330-331
    • /
    • 2006
  • Recently, plasma display panels (PDPs) are highlighted for the flat type display device. Therefore, much attention has been paid to secondary electron emission coefficient of the electrode protective material of PDPs. As PDPs is developing, the concern about secondary electron emission coefficient ($\gamma$) which is related with PDPs electrode protection material is increasing continually. So the concern about the way to how to measure secondary electron emission coefficient is on the rise. At present, the way to how to measure secondary electron emission coefficient is developed by some research groups, which is giving some research part's advance help. In this research, we have studied how to measure secondary electron emission coefficient which is related with various thin films more conveniently than previous measurement method. We studied the method of measurement of secondary electron emission coefficient (${\gamma}$) of amorphous silicon films by using Paschen's curve.

  • PDF

The Measurement Method of CO2 Emission for Construction Equipment using ZigBee Sensor (ZigBee 센서를 활용한 건설장비의 CO2 배출량 측정방법)

  • Chun, Jin-Ku;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.167-174
    • /
    • 2012
  • Recently, the effort to reduce $CO_2$ emission concerning certified emission reductions (CERs) is progressing lively with the institute in the center through lifecycle. However, the technique for reduce $CO_2$ emission is the first stage yet and the technique is insufficient to calculate with accuracy it. Therefore, this study tries to develop the method to measure by actual time $CO_2$ emission of construction equipment using Zigbee sensor. To review the method that calculate $CO_2$ emission, have classified the impact factors that affect at $CO_2$ emission by IPCC guideline. It also has review the application of Zigbee sensor that use wireless data communication. The reviewed result get that the measuring objects are the $CO_2$ emssion, RPM and fuel consumption of equipment, there are needs to search the year of equipment, waiting time, kind of vehicle and fuel that affect to $CO_2$ emission.

A Development of Lagrangian Particle Dispersion Model (Focusing on Calculation Methods of the Concentration Profile) (라그란지안 입자확산모델개발(농도 계산방법의 검토))

  • 구윤서
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.757-765
    • /
    • 1999
  • Lagrangian particle dispersion model(LPDM) is an effective tool to calculate the dispersion from a point source since it dose not induce numerical diffusion errors in solving the pollutant dispersion equation. Fictitious particles are released to the atmosphere from the emission source and they are then transported by the mean velocity and diffused by the turbulent eddy motion in the LPDM. The concentration distribution from the dispersed particles in the calculation domain are finally estimated by applying a particle count method or a Gaussian kernel method. The two methods for calculating concentration profiles were compared each other and tested against the analytic solution and the tracer experiment to find the strength and weakness of each method and to choose computationally time saving method for the LPDM. The calculated concentrations from the particle count method was heavily dependent on the number of the particles released at the emission source. It requires lots fo particle emission to reach the converged concentration field. And resulting concentrations were also dependent on the size of numerical grid. The concentration field by the Gaussian kernel method, however, converged with a low particle emission rate at the source and was in good agreement with the analytic solution and the tracer experiment. The results showed that Gaussian kernel method was more effective method to calculate the concentrations in the LPDM.

  • PDF

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

Analysis of Economic Load Dispatch for the Atmospheric Emission Control in Power Systems (대기환경오염물질의 배출량 제어를 위한 경제부하배분의 해석)

  • 김용하;정민화;송길영
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 1997
  • This paper presents a new economic load dispatch considering atmospheric emissions such as NOx and SO$_2$caused by the operation of fossil-fueled thermal generation in power systems. The proposed method is described for scheduling their output of thermal power units so as to comply with total emission constraint, area emission constraint and the both of those constraints. Also, by using a trade-off curve, representing all dispatch alternatives and conflict between the emission and the fuel cost, the sensitivity analysis of the emission and the fuel cost is applied to this algorithm. By the way, this proposed method is analyzed how dispatch changes as a function of the total environmental cost, and as a function of the relative weighting of individual environmental insults, e.g, NOx and SO$_2$. By applying the proposed method to the system, the usefulness of this method is verified.

  • PDF