• 제목/요약/키워드: Emission Wavelength

검색결과 625건 처리시간 0.029초

Global Far-UV Emission-line Images of the Vela Supernova Remnant

  • 김일중;선광일;민경욱
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.110.2-110.2
    • /
    • 2011
  • Nishikida et al. (2006) presented the first far-ultraviolet (FUV) em${\lambda}$ission-line images of the Vela supernova remnant (SNR) obtained with FIMS/SPEAR instrument. Those include C III ${\lambda}$977, O VI ${\lambda}{\lambda}$1032, 1038, Si IV+O IV] ${\lambda}{\lambda}$1393, 1403 (un-resolved), C IV ${\lambda}{\lambda}$1548, 1551 emission-line images. As a following work, we re-constructed these emission-line images using the new-version processed FIMS/SPEAR data. Additionally, we made N IV] ${\lambda}$1486, He II ${\lambda}$1640.5, O III] ${\lambda}{\lambda}$1661, 1666 emission-line images. The new-version images cover the whole region of the Vela SNR and show more resolved features than the old-version. We compare these FUV emission-line images with other wavelength (X-ray, optical, etc.) images obtained in previous studies.

  • PDF

ON THE LONG TIME SPECTRAL VARIABILITY OF NGC 5548

  • ISMAILOV, NARIMAN Z.;BASHIROVA, ULVIYYE Z.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.531-533
    • /
    • 2015
  • We have investigated the long term variability of the intensities of the broad-line region emission lines in the UV spectra of Seyfert I galaxy NGC 5548 from 1973-1996. We have obtained the following results: 1) a high level correlation between the intensities of emission lines as well as between intensities of emission lines and continuum fluxes was discovered. With increasing wavelength the correlation in both cases becomes weaker, 2) the relationship between the intensity of emission lines and the flux radiation in the continuum can be expressed by a power law function with coefficients of ${\alpha}{\approx}0.8-1.1$ for different lines. When the difference between the wavelengths of spectral lines and the continuum is increased, the value of the power function decreases, and 3) it was found that the magnitude of the variability of the line intensities are weaker than the range of variability of the continuum fluxes. The magnitude of the variability of the line intensities and the continuum fluxes increase at longer wavelengths.

신규 합성한 청색발광재료 nitro-DPVT를 사용한 백색 유기발광다이오드의 형광색소 도핑농도 및 NPB 층의 두께 변화에 따른 특성 분석 (Analysis of the Characteristics of a White OLED using the Newly Synthesized Blue Emitting Material nitro-DPVT by Varying the Doping Concentrations of Fluorescent Dye and the Thickness of the NPB Layer)

  • 전현성;조재영;오환술;윤석범
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.379-385
    • /
    • 2006
  • A stacked white organic light-emitting diode (OLED) having a blue/orange emitting layer was fabricated by synthesizing nitro-DPVT, a new derivative of the blue-emitting material DPVBi on the market. The white-emission of the two-wavelength type was successfully obtained by using both nitro-DPVT for blue~emitting material, orange emission as a host material and Rubrene for orange emission as a guest material. The basic structure of the fabricated white OLED is glass/ITO/NPB$(200{\AA})$/nitro-DPVT$(100{\AA})$/nitro-DPVT:$Rubrene(100{\AA})/BCP(70{\AA})/Alq_3(150{\AA})/Al(600{\AA})$. To evaluate the. characteristics of the devices, firstly, we varied the doping concentrations of fluorescent dye Rubrene from 0.5 % to 0.8 % to 1.3 % to 1.5 % to 3.0 % by weight. A nearly pure white-emission was obtained in CIE coordinates of (0.3259, 0.3395) when the doping concentration of Rubrene was 1.3 % at an applied voltage of 18 V. Secondly, we varied the thickness of the NPB layer from $150{\AA}\;to\;200{\AA}\;to\;250{\AA}\;to\;300{\AA}$ by fixing doping with of Rubrene at 1.3 %. A nearly pure white-emission was also obtained in CIE coordinates of (0.3304, 0.3473) when the NPB layer was $250-{\AA}$ thick at an applied voltage of 16 V. The two devices started to operate at 4 V and to emit light at 4.5 V. The external quantum efficiency was above 0.4 % when almost all of the current was injected.

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

InGaAs/AlGaAs 양자선 래이저에서 관찰된 이상 방출 스펙트럼 (Anomalous Emission Spectra Observed in InGaAs/AlGaAs Quantum-Wire Lasers)

  • 김경찬;김태근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2020-2021
    • /
    • 2004
  • Distributed optical feedback by gain coupling in V-groove quantum-wire lasers is investigated using InGaAs/AlGaAs active materials grown by metalorganic chemical vapor deposition (MOCVD). In order to avoid grating overgrowth during the fabrication of DFB structures, a newly developed constant MOCVD growth method is employed. Gain anisotropy in emission spectra near Bragg wavelength, resulting from optical feedback along the DFB direction, is clearly observed at room temperature.

  • PDF

Detection of the fluorescent emission of hydrogen in the Taurus cloud

  • Dae-Hui Lee;In-Su Yuk;Jang-Hyeon Park;Ho Jin;Gwang-Il Seon;Uk-Won Nam;Won-Yong Han;Gyeong-Uk Min;Gwang-Seon Yu
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권1호
    • /
    • pp.99-99
    • /
    • 2004
  • We detected and analyzed molecular hydrogen fluorescence in the Taurus Cloud using the Far-ultraviolet Imaging Spectrograph (FIMS) on the STSAT-1 which was launched at SeP. 27 2003. FIMS is optimized for observing diffuse emission lines in the interstellar medium in the wavelength bands of 900-l150 and 1300-1700 angstrom. The Taurus region is a local molecular cloud which is good for studying molecular hydrogen fluorescence emissions. (omitted)

  • PDF

2D Slab Silicon Photonic Crystal for Enhancement of Light Emission in Visible Wavelengths

  • Cui, Yonghao;Lee, Jeong-Bong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.887-890
    • /
    • 2008
  • We present 2D slab silicon-based photonic crystal optical insulator to enhance light emission efficiency of light-emitting diode (LED). A 2D slab silicon photonic crystal is designed in such a way that light emitting diode die can be placed in the middle of the silicon photonic crystal. The device creates light propagation forbidden region in horizontal plane for Transverse Electric (TE) light with the wavelength range of 450 nm to 600 nm.

  • PDF

Synthesis of Fluorescent Thiophene-derivatized Pentytiptycenes and Their Aggregate Behaviors

  • 송진우
    • 통합자연과학논문집
    • /
    • 제3권1호
    • /
    • pp.28-32
    • /
    • 2010
  • Thiophene-derivatized pentiptycenes were synthesized and characterized by NMR and UV-Vis spectroscopy. Aggregation behavior of thiophene-derivatized pentiptycenes was monitored by the measurement of fluorescence. Fluorescence intensities for the thiophene-derivatized pentiptycenes and thiophene-derivatized pentiptycenes aggregates were compared. There is no shift in the maximum of the emission wavelength. In the range of water fraction between 20% and 40%, the emission intensity of thiophene-derivatized pentiptycene aggregates remains almost identical. Fluorescence efficiency incresaed by about 5 times higher when the thiophene-derivatized pentiptycenes forms the aggregates in solution.

32 채널 파장분할다중화 광통신 전송에서 이득포화 광신호 영향 비교 (The effect comparison using saturation tone signals for optical wavelength division multiplexing communications)

  • 최보훈
    • 한국정보통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.2037-2042
    • /
    • 2014
  • 32 채널 이상의 파장다중화 광신호 전송에서 이득포화 광신호 사용법이 적용되었고, 이 이득 포화 광신호의 세 가지 다른 적용 방법들이 비교되었다. 이 세 가지 방법은 고출력 DFB LD 들만을 사용하는 경우, 광증폭기로 증폭된 입력광원들을 사용하는 경우, 그리고 하나의 이득포화 광원과 소수의 파장다중화 광원들을 사용하는 경우들이다. 하나의 포화 광원을 이용한 경우는 다시 이 광원의 파장 의존성을 확인하기 위해 1532.3 nm, 1545.7 nm, 그리고 1558.2 nm의 세 가지 경우가 비교되었다. 그 결과 입력광원이 증폭기로 증폭되더라도 ASE에 의한 잡음은 영향이 미미하였음을 확인하였고, 포화 광원의 파장위치는 장파장인 경우 이득이 1 dB 이상 감소하였으며 그 원인이 분석되었다.

대기압 유전체배리어방전의 발광특성 (Optical Emission Characteristics of Atmospheric Pressure Dielectric Barrier Discharge)

  • 김진기;김윤기
    • 한국재료학회지
    • /
    • 제25권2호
    • /
    • pp.100-106
    • /
    • 2015
  • Plasma properties of dielectric barrier discharges (DBDs) at atmospheric pressure were measured and characterized using optical emission spectroscopy. Optical emissions were measured from argon, nitrogen, or air discharges generated at 5-9 kV using 20 kHz power supply. Emissions from nitrogen molecules were markedly measured, irrespective of discharge gases. The intensity of emission peaks was increased with applied voltage and electrode gap. The short wavelength peaks (315.9 nm and 337.1 nm) measured at the middle of DBDs were significantly increased with applied voltage. The optical emission from DBDs decreased with the addition of oxygen gas, which was especially significant in argon discharge. Emission from oxygen molecules cannot be measured from air discharge and argon discharge with 4.8% oxygen. The emission intensity at 337.1 nm and 357.7 nm related with nitrogen molecule was sensitively changed with electrode types and discharge voltages. However, the pattern of argon emission spectrum was nearly the same, irrespective of electrode type, oxygen content, and discharge voltage.