• Title/Summary/Keyword: Emission Signal

Search Result 691, Processing Time 0.027 seconds

Application of Laser-Induced Breakdown Spectroscopy (LIBS) for In-situ Detection of Heavy Metals in Soil (토양내 중금속 실시간 탐지를 위한 레이저 유도붕괴 분광법의 활용에 대한 소개)

  • Ko, Eun-Joung;Hamm, Se-Yeong;Kim, Kyoung-Woong
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.563-574
    • /
    • 2007
  • Laser induced breakdown spectroscopy (LIBS) is a recently developed analytical technique that is based upon the measurement of emission lines generated by atomic species close to the surface of the sample, thus allowing their chemical detection, identification and quantification. With powerful advantages of LIBS compared to the conventional analytical methodology, this technique can be applied in the detection of heavy metals in the field. LIBS allows the rapid analysis by avoiding laborious chemical steps. LES have already been applied for the determination of element concentration in a wide range of materials in the solid, liquid and gaseous phase with simplicity of the instrument and diversity of the analytical application. These feasibility of rapid multi elemental analysis are appealing proprieties for the in-situ analytical technique in geochemical investigation, exploration and environmental analysis. There remain still some limitations to be solved for LIBS to be applied in soil environment as an in-situ analytical technology. We would like to provide the basic principle related to the plasma formation and laser-induced breakdown of sample materials. In addition, the matrix effect, laser properties and the various factors affecting on the analytical signal of LIBS was dealt with to enhance understanding of LIBS through literature review. Ultimately, it was investigated the feasibility of LIBS application in soil environment monitoring by considering the basic idea to enhance the data quality of LIBS including the calibration method for the various effects on the analytical signal of LIBS.

Development of PET Detector Module Measuring DOI using Multiple Reflectors (여러 반사체를 사용한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Kim, Neung Gyun;Kim, Gu;Kwak, Jong Hyeok;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.825-830
    • /
    • 2019
  • A detector module measuring a depth of interaction was developed using silicon photomultiplier (SiPM) and two layers of scintillation crystal array treated with multiple reflectors. When reconstructing an image based on a signal obtained by using different types of reflector of each layer, the interaction positions of scintillation pixels and gamma rays could be tracked by utilizing the feature that all scintillation pixels were recorded at different positions. The bottom layer uses a specular reflector, and the top layer uses a diffuse reflector to differently process the size of the signal obtained from the SiPM. The optical grease was used to recude the sharp refractive index change between the layers of scintillator and the SiPM. The signals obtained from the 16 SiPMs were reduced to four signals using the Anger equations, and the images were reconstructed using them. All the scintillation pixels composed of the two layers appeared in the reconstructed image, which distinguished the layer where the scintillation pixels and gamma rays interacted. If the detectors, which measure the interaction depth of two layers using different reflectors, will be applied to preclinical positron emission tomography, the degradation of spatial resolution appearing outside the field of interest could be solved.

A Design and Implementation of Digital Ultra-Narrowband Walky-Talky Using Direct Conversion Method (직접 변환 방식을 이용한 디지털 초협대역 무전기 설계 및 구현)

  • Chong Young-Jun;Kang Min-Soo;Yoo Sung-Jin;Chung Tae-Jin;Oh Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.603-614
    • /
    • 2005
  • In this paper, digital ultra-narrowband Walky-Talky using direct conversion method for CQPSK modulation scheme is implemented with satisfying the requirements of APCO P25. RF transceiver design and implementation scheme that minimize the influence of DC-offset and AC-coupling at ultra-narrowband is proposed. This scheme also minimizes the influence of nonlinear characteristic at power amplifier fir CQPSK modulation method. Test results of full system including DSP module and direct conversion RF transceiver show that FCC emission mask at 36.8 dBm PEP meets the standard requirements. The characteristic of receiver AGC by PWM control signal is linear at 40 dB dynamic range and voice communication at input power level of -116 dBm is successful. Also it is verified that the performance of BER versus frequency offset and versus SNR meets the standard requirements.

Mechanism of Micro-V Grooving with Single Crystal Diamond Tool (단결정 다이어몬드 공구를 이용한 Micro-V 홈 가공기구)

  • Park D.S.;Seo T.I.;Kim J.K.;Seong E.J.;Han J.Y.;Lee E.S.;Cho M.W.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1223-1227
    • /
    • 2005
  • Fine microgroove is the key component to fabricate micro-grating, micro-grating lens and so on. Conventional groove fabrication methods such as etching and lithography have some problems in efficiency and surface integrity. This study deals with the creation of ultra-precision micro grooves using non-rotational diamond tool and CNC machining center. The shaping type machining method proposed in the study allows to produce V-shaped grooves of $40\mu{m}$ in depth with enough dimensional accuracy and surface. For the analysis of machining characteristics in micro V-grooving, three components of cutting forces and AE signal are measured and processed. Experimental results showed that large amplitude of cutting forces and AE appeared at the beginning of every cutting path, and cutting forces had a linear relation with the cross-sectional area of uncut chip thickness. From the results of this study, proposed micro V-grooving technique could be successfully applied to forming the precise optical parts like prism patterns on light guide panel of TFT-LCD.

  • PDF

A Study on the NC Embedding of Vision System for Tool Breakage Detection (공구파손감지용 비젼시스템의 NC실장에 관한 연구)

  • 이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

Cerebral Hemodynamic Analysis in Pediatric Moyamoya Patients using Perfusion Weighted MRI (관류 강조 자기공명 영상을 이용한 소아 모야모야 환아의 뇌 혈역학 분석)

  • Chang, Won-Seok;Kim, Tae-Gon;Lee, Seung-Koo;Choi, Jung-Uhn;Kim, Dong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.207-212
    • /
    • 2005
  • Objective: Classically, single photon emission tomography is known to be the reference standard for evaluating the hemodynamic status of patients with moyamoya disease. Recently, T2-weighted perfusion magnetic resonance(MR) imaging has been found to be effective in estimating cerebral hemodynamics in moyamoya disease. We aim to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic status of moyamoya disease. Methods: The subjects were fourteen moyamoya patients(mean age: 7.21 yrs) who were admitted at our hospital between Sep. 2001 to Sep 2003. Four normal children were used for control group. Perfusion MR imaging was performed before any treatment by using a T2-weighted contrast material-enhanced technique. Relative cerebral blood volume(rCBV) and time to peak enhancement(TTP) maps were calculated. Relative ratios of rCBV and TTP in the anterior cerebral artery(ACA), middle cerebral artery(MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery(PCA) in each cerebral hemispheres. Using this data, we analysed the hemodynamic aspect of pediatric moyamoya disease patients in regarding to the age, Suzuki stage, signal change in FLAIR MR imaging, and hemispheres inducing symptoms. Results: The mean rCBV ratio of ACA, MCA did not differ between normal children and moyamoya patients. However the significant TTP delay was observed at ACA, MCA territories (mean = 2.3071 sec, 1.2089 see, respectively, p < 0.0001). As the Suzuki stage of patients is advanced, rCBV ratio is decreased and TTP differences increased. Conclusion: Perfusion MR can be applied for evaluating preoperative cerebral hemodynamic status of moyamoya patients. Furthermore, perfusion MR imaging can be used for determine which hemisphere should be treated, first.

A Phase Stabilization System of EFPI for Damage Detection of Composite (복합재료 파손 검출을 위한 EFPI 센서 위상 안정화 시스템)

  • Kim,Dae-Hyeon;Gu,Bon-Yong;Bang,Hyeong-Jun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.44-49
    • /
    • 2003
  • In case of an extrinsic Fabry-Perot interferometric sensor, the phase compensating technique is particularly necessary in applying the interferometer to detecting acoustic emission signals because of signal-fading problems. The technique makes it possible to maintain the phase at the quadrature point. In this paper, we developed the stabilization control sensor system that is composed of a broadband light source, a tunable Fabry-Perot (F-P) filter and a control-circuit board. A tension test of a composite specimen was performed to verify if the developed system could compensate the phase change induced from the tension strain and keep the phase at the quadrature point.

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

EMI Reduction Analysis by a Conductor between Frames (프레임을 연결하는 전도체의 구조가 EMI 감소에 미치는 영향 분석)

  • Koh, Eun-Kwang;Shim, Min-Kyu;Hong, Eun-Ju;Lee, Jai-Yeol;Park, Seung-Hun;Kwak, In-Gu;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • In this paper, we investigated EMI(electromagnetic interference) reduction by conductor connection, which was used for fixing and electrical grounding between frames. Conductor connects two frames and then it provides the decrease of return path of signal current. To prove the effect of conductor, we measured/simulated the RE(radiated emission) with/without conductors between the two frames. From the measured/simulated results, we observed that EMI decreased about 1$\sim$10 dB at the frequency range of 30 MHz to 1 GHz. VNA(vector network analyzer) was used to measure the S parameters and the RE was measured in a 3 m anechoic chamber. The simulated and measured results are compared and discussed.

A Study on the EMI Denoising Using the Ferrite Core for Facsimile (페라이트 코어를 이용한 팩시밀리에서의 EMI 제거에 관한 연구)

  • Yun, Ki-Bang;Yu, Rin;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.5
    • /
    • pp.28-35
    • /
    • 2000
  • In this paper, we design a ring inductor using the ferrite core to denoise the EMI(Electromagnetic Interference) for facsimile. The EMI for facsimile is radiated from the signal line of PSTN(Public Switching Telephone Network) between facsimile and PSTN. We denoise the radiated noise by inserting a ferrite core(Ni-Zn) between facsimile and PSTN. Even though we may denoise the radiated noise using two or more than two ferrite cores, we only concentrate on denoising EMI by adjusting number of turns of one ferrite core since it gives economical gain. As a result of measuring EMI using the designed inductor with 4 turns inserted in the line connected between facsimile and PSTN, the value of radiated emission is reduced below 30 dB$\mu$V/m.

  • PDF