• Title/Summary/Keyword: Emission Path

Search Result 107, Processing Time 0.03 seconds

An Investigation on Gridline Edges in Screen-Printed Crystalline Silicon Solar Cells

  • Kim, Seongtak;Park, Sungeun;Kim, Young Do;Kim, Hyunho;Bae, Soohyun;Park, Hyomin;Lee, Hae-Seok;Kim, Donghwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.490.2-490.2
    • /
    • 2014
  • Since the general solar cells accept sun light at the front side, excluding the electrode area, electrons move from the emitter to the front electrode and start to collect at the grid edge. Thus the edge of gridline can be important for electrical properties of screen-printed silicon solar cells. In this study, the improvement of electrical properties in screen-printed crystalline silicon solar cells by contact treatment of grid edge was investigated. The samples with $60{\Omega}/{\square}$ and $70{\Omega}/{\square}$ emitter were prepared. After front side of samples was deposited by SiNx commercial Ag paste and Al paste were printed at front side and rear side respectively. Each sample was co-fired between $670^{\circ}C$ and $780^{\circ}C$ in the rapid thermal processing (RTP). After the firing process, the cells were dipped in 2.5% hydrofluoric acid (HF) at room temperature for various times under 60 seconds and then rinsed in deionized water. (This is called "contact treatment") After dipping in HF for a certain period, the samples from each firing condition were compared by measurement. Cell performances were measured by Suns-Voc, solar simulator, the transfer length method and a field emission scanning electron microscope. According to HF treatment, once the thin glass layer at the grid edge was etched, the current transport was changed from tunneling via Ag colloids in the glass layer to direct transport via Ag colloids between the Ag bulk and the emitter. Thus, the transfer length as well as the specific contact resistance decreased. For more details a model of the current path was proposed to explain the effect of HF treatment at the edge of the Ag grid. It is expected that HF treatment may help to improve the contact of high sheet-resistance emitter as well as the contact of a high specific contact resistance.

  • PDF

Equalization Digital On-Channel Repeater Part 1 : Laboratory Test Results (등화형 디지털 동일 채널 중계기 Part 1 : 실험실 테스트 결과)

  • Park Sung Ik;Lee Yong-Tae;Eum Homin;Seo Jae Hyun;Kim Heung Mook;Kim Seung Won;Lee Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.210-220
    • /
    • 2005
  • This paper presents and analyzes laboratory test results of Equalization Digital On-Channel Repeater (EDOCR) using ATSC(Advanced Television Systems Committee) terrestrial digital TV broadcasting system. The EDOCR laboratory test, which is done at CRC(Communications Research Centre) Canada, is classified to receiver test, transmitter test, and synchronization test between transmission and reception frequencies. The receiver part includes feedback signal, random noise, single echo, multi-path ensemble, and NTSC/DTV interference test. The transmitter part includes out-of channel emission, quality of transmitting signal, and phase noise test. By the field test results, the receiver part of the EDOCR eliminates average 5.5 dB of feedback or single echo signal in range of 0 to 11 ${\mu}s$ and has average 18.6 dB at TOV(Threshold of Visibility) under random noise environment. Also, the transmitter part of the EDOCR satisfies the specification of US FCC(Federal Communications Commission), and frequency difference between transmitter and receiver is zero.

A study of ubiquitous-RTLS system for worker safety (작업자 안전관리를 위한 유비쿼터스-실시간 위치추적시스템 연구)

  • Kim, Young-Baig
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1C
    • /
    • pp.1-7
    • /
    • 2012
  • At the industrial work site, the manufacturing process is being automated to improve work efficiency. However, it is often difficult to automate the entire manufacturing process, and there are spaces in which workers there are constantly exposed to danger. To protect such workers from the danger, this paper studied a worker safety management system for the industrial work site which uses a location recognition system and which is based on the Ubiquitous-Wireless Sensor Network (U-WSN). Using wireless signals, the distance between two devices can be measured and the location of a worker can be calculated using triangularization in 3-D. But at the industrial work sites where there are a lot of steel and structures, errors occur due to signal reflection and multi-path, etc., which makes it difficult to get the accurate location. To address this problem the following was done: first, a circular polarization patch antenna appropriate to the work site was used to reduce the degree of error that may occur from the antenna emission pattern and the particular Line of Sight (LOS); second, a 3-D localization technique and a filtering algorithm were used to improve the accuracy of location determination. The developed system was tested by using it on a wharf crane to validate its accuracy and effectiveness. The proposed location recognition system is expected to contribute greatly in ensuring the safety of workers at industrial work sites.

Effects of Grassed Swale Lengths on Reduction Efficiencies of Non-point Source Pollutants (식생수로 길이가 비점오염물질 저감효율에 미치는 영향)

  • Paek, Seoungbong;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.387-396
    • /
    • 2013
  • Non-point pollution source is difficult to control due to uncertain outflow path and emission. So, There are many development and research to Best Management Practices(BMP) established to manage the Non-point pollution source. Besides, various methods of estimated efficiency to exact assessment of BMP is presented. In this study, the impact about length of Grassed Swale on reduction efficiency based on monitoring results of Grassed Swale by length is studied. By estimating Grassed Swale reduction efficiency in a variety of methods, the difference between the methods of estimated efficiency was compared with those that. Estimated efficiency method using ER, SOL, ROL, ROF, SOLF, and ROLF methods is analyzed. EMC analysis result is high inflow and outflow concentration distinction organic compound for nutritive salts The result of efficiency analysis along Grassed Swale length sharply increases in a Grassed Swale inlet. After this increase, the efficiency gradually decreases. This is expected that cistern installed in the end of the front. To obtain a stable reduction efficiency of Grassed Swale, minimum length 30m of Grassed Swale should be enough. Also, in order to efficiently and economically design Grassed Swale, the researches on length of Grassed Swale are needed rather than simple analysis of efficiency.

Analysis of Regional Implementation Conditions and Industrial Strategies for Carbon Neutrality in China (중국 탄소중립 지역별 이행여건 및 산업전략 분석)

  • Yu-jeong Jeon;Su-han Kim
    • Analyses & Alternatives
    • /
    • v.7 no.2
    • /
    • pp.179-207
    • /
    • 2023
  • Carbon neutrality, the international community's practical challenge in response to climate change, is becoming a key industrial strategy for the future development of nations. Despite concerns that China, as an economic powerhouse in the G2, may face challenges leading global climate change efforts due to its high-carbon-emitting industrial structure, it is leveraging carbon neutrality to enhance its industrial competitiveness. The Chinese government has formulated national policies for achieving carbon neutrality and detailed sector-specific plans to implement them. In particular, it aims to leverage carbon neutrality industrial strategies as a lever for adjusting the domestic industrial structure and fostering new industries, at the same time responding to international climate norms and external pressures. However, the effectiveness of carbon-neutral industrial strategies is expected to vary based on regional conditions such as economic and industrial levels. This article analyzes the regional conditions for implementing carbon neutrality in China, as well as the contents and characteristics of major industrial policies. Due to differing levels of economic development and industrial structures, significant variations in carbon emissions, size, emission sources, and efficiency are inevitable across regions. These disparities introduce diverse initial conditions and endogenous factors in pursuing carbon-neutral goals, limiting the direction and implementation of carbon-neutral industrial strategies favoring certain regions. In particular, the extent of policy autonomy granted to local governments regarding carbon neutrality implementation will influence the regional dynamics of central-local environmental governance. Consequently, it is crucial to emphasize regional monitoring alongside comprehensive national research to accurately navigate the path towards carbon neutrality in China. In summary, the article underscores the importance of understanding regional variations in economic development, industrial structure, and policy autonomy for successful carbon neutrality implementation in China. It highlights the need for regional monitoring and comprehensive national research to determine a more precise direction for achieving carbon neutrality.

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.