• Title/Summary/Keyword: Emission Factors

Search Result 928, Processing Time 0.024 seconds

Estimate of $CH_4$ Emission Factors in Municipal Wastewater Treatment Plants (하수와 소화슬러지의 $CH_4$가스 배출원단위 산정에 관한 연구)

  • Yang, Hyung-Jae;Park, Jung-Min
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.39-46
    • /
    • 2008
  • In order to study the estimate of $CH_4$ emission factors in the municipal wastewater treatment plants, the active sludge process, 5-stage process, Denipho process, and SBR process were investigated. When active sludge process, 5-stage process, and Denipho process were used in wastewater treatment plant, the $CH_4$ emission factors were 2.88, 1.61, and 0.57 g-$CH_4/kg$-BOD, respectively. On the other hand, in the case of SBR process, it was 4.14 g-$CH_4/kg$-BOD. These results indicate that SBR process was effective for $CH_4$ emission in municipal wastewater treatment plants. Using the above processes, the methane emission factor and amount of waste water sludge were $4.78m^3/t$ and $12,204,506m^3/yr$, respectively. The remove of BOD was a range of $93.91{\sim}98.63%$.

A Study on the Numerical Analysis of VOCs Emission from Plywood Floor Material (수치해석을 활용한 합판마루 바닥재의 VOCs 방출에 관한 연구)

  • Kim Ji-Hye;Kang Dong-Hwa;Choi Dong-Hee;Kim Sun-Sook;Yeo Myoung-Souk;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1123-1131
    • /
    • 2005
  • The floor material is known as the most influential emission source of the residential building, because most floor material is made of wood compound and adhesive like a plywood flooring. Moreover, floor heating system keeps the inside temperature of the material high. As the emission of hazardous chemical compound from the construction material is influenced by many factors, it is necessary to analyze the emission characteristics of the floor material to improve IAQ. In this study, numerical analysis is performed to investigate the emission characteristics of the floor material affected by several factors such as temperature, air exchange rate, initial concentration, and internal diffusion coefficient. A simulation program is also written based on the mass transfer theory. The simulation results show that there is some level of difference on the TVOC concentration when each of the factors is variable.

Development of NH3 Emission Factors using a Dynamic Flux Chamber in a Sewage Treatment Plant (부유형 챔버를 이용한 하수처리장에서의 암모니아 배출 특성 연구)

  • Jeon, Eui-Chan;Sa, Jae-Hwan;Park, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.263-273
    • /
    • 2005
  • In this study, the major emission procedures and emission characteristics were identified at the site of sewage treatment plant which is one of the major sources of ammonia. At the same time the emission factors and emission rates were estimated. In order to calculate the emission flux, we used a Dynamic Flux Chamber(DFC), which is found to be a proper sampling devise for area sources such as sewage treatment plant. It was found that the most stable sampling condition was when the stirrer's speed of DFC was 120RPM, and it would be the best time to take a sample 60 minutes later after setting the chamber. The relatively higher flux was shown in Autumn compared to summer and winter. Annual ammonia emission rates procedures were calculated as $906.32{\mu}g/activity-ton$, $1,114.72{\mu}g/activity-ton$ and $437.53{\mu}g/activity-ton$ each at the primary settling basin, aeration basin and the final settling basin, respectively. The ammonia emission rate the highest at in the aeration basin according to this test. This results was due to that the surface of aeration basin or the final settling basin is relatively wider than the primary settling basin.

Application and Development of Carbon Emissions Factors for Deciduous Species in Republic of Korea - Robinia pseudoacacia, Betula platyphylla, and Liriodendron tulipifera - (국내 활엽수종의 탄소배출계수 개발 및 적용 - 아까시나무, 자작나무, 백합나무를 대상으로 -)

  • Lee, Sun Jeoung;Yim, Jong Su;Kang, Jin Take;Kim, Raehyun;Son, Yowhan;Park, Gawn Su;Son, Yeong Mo
    • Journal of Climate Change Research
    • /
    • v.8 no.4
    • /
    • pp.393-399
    • /
    • 2017
  • According to the United Nations Framework Convention on Climate Change (UNFCCC), all parties have to submit the national GHG inventory report. Estimating carbon stocks and changes in Land Use, Land-Use Changes and Forestry (LULUCF) needs an activity data and emission factors. So this study was conducted to develop carbon emission factor for Robinia pseudoacacia L., Betula platyphylla var. japonica, and Liriodendron tulipifera. As a result, the basic wood density ($g/cm_3$) was 0.64 for R. pseudoacacia, 0.55 for B. platyphylla, and 0.46 for L. tulipifera. Biomass expansion factor was 1.47 for R. pseudoacacia, 1.30 for B. platyphylla, and 1.24 for L. tulipifera. Root to shoot ratio was 0.48 for R. pseudoacacia, 0.29 for B. platyphylla, and 0.23 for L. tulipifera. Uncertainty of estimated emission factors on three species ranged from 3.39% to 27.43% within recommended value (30%) by IPCC. We calculated carbon stock and change using these emission factors. Three species stored carbon in forest and net $CO_2$ removal was $1,255,398\;t\;CO_2/yr$ during 5 years. So we concluded that our result could be used as emission factors for national GHG inventory report on forest sector.

Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House (강제환기식 산란계 사육시설의 PM, NH3 발생·배출 특성 조사)

  • Jang, Dong-Hwa;Yang, Ka-Young;Kwon, Kyeong-Seok;Kim, Jong-Bok;Ha, Tae-Hwan;Jang, Yu-Na
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.99-110
    • /
    • 2022
  • In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

Fugitive Emission Characteristics of HFC-134a from Waste Kimchi Refrigerator (폐김치냉장고에서의 HFC-134a 탈루배출 특성에 대한 연구)

  • Kim, Eui-Kun;Kim, Seungdo;Lee, Young Phyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • In 1995 Kimchi refrigerator was developed at first, and has used HFC-134a as refrigerant. Kimchi refrigerator has been made 1,044,694 on the basis of 2010, disposed about 160,000 per year. Although mobile air conditioning, commercial refrigerator, general refrigerator is regarded as a major source of HFC-134a, little information is available for its emission characteristics of HFC-134a. This paper addresses the fugitive emission factors of Kimchi refrigerator at use-phase and disposal-phase. The residual quantities of Korean-made fifty three waste Kimchi refrigerators were weighed using a commercial recover of refrigerants to determine the emission factors at the disposal-phase. On the other hand, the emission factors at use-phase were estimated from the residual quantities and operating times. The average residual rate of forty three scarp Kimchi refrigerators is determined to be $74.6{\pm}5.2%$. The emission factor at the use-phase is estimated to be $3.5{\pm}0.8%/yr$ as a result of using average age of 11.7 years and the average residual rate determined here. The emission factor at the disposal-phase is determined to be 31.3% after adopting 58% of the recycling rate of refrigerant reported by Recycling Center. We estimate 3.1 g/yr for the average emission quantity of HFC-134a per operating refrigerator, while 22.5 g for that per waste Kimchi refrigerator. Since the chemical compositions of refrigerant of waste Kimchi refrigerator were the same as those of new refrigerant, it is expected that the HFC-134a recovered from waste Kimchi refrigerator can be reused for refrigerant.

Development of Greenhouse Gas (CH4 and N2O) Emission Factors for Anthracite Fired Power Plants in Korea (국내 무연탄 화력발전소의 온실가스 배출계수 개발 - CH4, N2O를 중심으로 -)

  • Lee, See-Hyung;Kim, Jin-Su;Lee, Seong-Ho;Sa, Jae-Hwan;Kim, Ki-Hyun;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.562-570
    • /
    • 2009
  • Although anthracite power plant acts as the important source of greenhouse gas emissions, relatively little is known about its emission potentials. Especially, because the emissions of Non-$CO_2$ greenhouse gas $CH_4$ and $N_2O$ are strongly dependent on fuel type and technology available, it is desirable to obtain the information concerning their emission pattens. In this study, the anthracite power plants in Korea were investigated and the emission gases were analyzed using GC/FID and GC/ECD to develop Non-$CO_2$ emission factors. The anthracite samples were also analyzed to quantity the amount of carbon and hydrogen using an element analyzer, while calorie was measured by an automatic calorie analyzer. The emission factor of $CH_4$ and $N_2O$ computed through the gas analysis corresponded to 0.73 and 1.98 kg/TJ, respectively. Compared with IPCC values, the $CH_4$ emission factor in this study was about 25% lower, while that of $N_2O$ was higher by about 40%. More research is needed to extend our database for emission factors of various energy-consuming facilities in order to stand on a higher position.

An investigation and forecast on CO2 emission of China: Case studies of Beijing and Tianjin

  • Wen, Lei;Ma, Zeyang;Li, Yue;Li, Qiao
    • Environmental Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.407-416
    • /
    • 2017
  • $CO_2$ emission is increasingly focused by public. Beijing and Tianjin are conceived to be a new economic point of growth in China. However, both of them are suffering serious environmental stress. In order to seek for the effect of socioeconomic factors on the $CO_2$ emission of this region, a novel methodology -symbolic regression- is adopted to investigate the relationship between $CO_2$ emission and influential factors of Beijing and Tianjin. Based on this method, $CO_2$ emission models of Beijing and Tianjin are built respectively. The models results manifested that Beijing and Tianjin own different $CO_2$ emission indicators. The RMSE of models in Beijing and Tianjin are 255.39 and 603.99, respectively. Further analysis on indicators and forecast trend shows that $CO_2$ emission of Beijing expresses an inverted-U shaped curve, whilst Tianjin owns a monotonically increasing trend. From analytical results, it could be argued that the diversity rooted in different development orientation and the mixture of different natural and industrial environment. This research further expands the investigation on $CO_2$ emission of Beijing and Tianjin region, and can be used for reference in the study of carbon emissions in similar regions. Based on the investigation, several policy suggestions are presented.

Fugitive Emission Characteristics of HFC-134a from Reefer Container (냉동컨테이너에서의 HFC-134a 탈루배출 특성에 대한 연구)

  • Kim, Eui-Kun;Kim, Seungdo;Lee, Young Phyo;Byun, Seokho;Kim, Hyerim
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.110-118
    • /
    • 2014
  • This paper addresses the fugitive emission factors of Reefer Container at use-phase and disposal-phase. The residual quantities and operation time of thirty nine Container were weighed, using a commercial recover of refrigerants to determine the emission factors at the use-phase. The emission factor at the disposal-phase, refrigerant is accomplished has not recycled, the residual rate was assumed that the emission factor. The average residual rate of thirty nine Container is determined to be $70.8{\pm}4.0%$. The emission factor at the use-phase is estimated to be $4.9{\pm}0.9%/yr$ in the case of using average age of 8.1 years and the average residual rate determined here. We estimate 162.7 g/yr for the average emission quantity of refrigerant per operating Container, while 2038.1 g for that per waste Container. Since the chemical compositions of refrigerant of waste Container were the same as those of new refrigerant, it is expected that the refrigerant recovered from waste Container can be reused for refrigerant.

Evaluation of impact factors on emission rate of formaldehyde from MDF based on chamber tests (챔버실험을 통한 MDF에서의 포름알데히드 방출의 영향인자 평가)

  • Yoo, Bok-Hee;Kim, Gi-In
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.204-207
    • /
    • 2009
  • The purpose of this study was to evaluation of impact factors, which are temperature and relative humidity on formaldehyde emission from MDF(Medium Density Fiberboard). The test was carried out at 4 specimens that were different of temperature and humidity by using small chamber system. Formaldehyde was sampled and analyzed by HPLC. The results of this study were as follows; 1) When the temperature increased from 25 to $35^{\circ}C$ at 50%, the emission rate of formaldehyde increased 1.0-1.6 times. 2) When the RH increased from 50% to 80% at $25^{\circ}C$, the emission rate of formaldehyde decreased 0.6 times. 3) The enhancement effect of temperature on Formaldehyde under RH of 50% was more significant than under RH of 80%.

  • PDF