• Title/Summary/Keyword: Emergency preparation equipments

Search Result 5, Processing Time 0.019 seconds

A Study on the Activation·Specification of 119 Rescue & Care in JeJu (제주도 119구조·구급대의 활성화 및 전문화 방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.153-168
    • /
    • 2002
  • Since 1992, conventional fire fighting businesses have been converted into a metropolitan autonomous fire fighting system to be ready for a variety of disasters. However, the corresponding investment has been overlapped due to the non-integration of businesses to prevent any potential disasters, and a series of collaborative systems have been not functioning so well. In the meantime, our fire fighting sector has been trying to set up its own clean and faithful position by abolishing any inconvenient system or outsourcing private sectors, and expanded its work scope from conventional fire fighting even to rescue and emergency works. While focusing on handling disaster, the fire fighting sector has been widely trusted and reliable throughtout our nation. Moreover, our fire fighting sector has secured nation wide mobile organizations, technical personnel by field, special equipments and independent communication network. In addition, the fire fighting sector has knowledges, expertise and capabilities required for managing disasters, while in charge of almost every disaster management works including fire, explosion, collapse, disaster and flood. It becomes an organization for comprehensive disaster management under an absolute national trust, which is based on the system for prevention, preparation and countermeasure against a variety of disasters. Thus, our fire fighting sector must make many efforts and try to modernize conventional education and training. The ways to facilitate rescue and emergency works may include the nurture of technical fire fighting personnel along with modernized equipments, the reinforcement of rescue and emergency education, the facilitation of operating civil defense corps, the facilitation of operating volunteer fire fighting corps, the better arrangement of 119 briefing room for public healthcare in provincial offices, the sterilization of rescue instruments and equipments the better repair education for emergency rescue member, the establishment of regional emergency assistant system and the expansion of fire fighting personnel and equipments. In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations: Building up security system along with operational expansion, building up a system for emergency medical treatment, building up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119 we can review the following considerations : Improving the education for fire fighting training corps under Jeju Provincial Fire and Disaster Management Department, providing rescue members with more opportunities for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. If these requirements are met, it is expected that the fire fighting departments in Jeju province can cope with every accident and disaster a little more rapidly and quickly in compliance with local needs, so that they can keep their own position as a public fire fighting organization which may be trusted by the public.

  • PDF

A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility (보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2009
  • Recently, the number of child care facility and social demand for high quality child care service increase suddenly. Especially, social atmosphere about fire safety is more sensitive in Korea. The majority of the residents in a child care facility are composed of early childhood having difficulty to evacuate, and therefore the number of stories of a building and the appropriateness of a evacuation equipment play an important role in the evacuation safety. In this study, problems and improvements for the evacuation safety are dealt with the present conditions of child care facilities, the comparative analysis between domestic and foreign standards, the research on the actual condition of evacuation equipments, and so on. The study brings to a conclusion that it is necessary to systematize the regulations regarding fire safety, to connect fire-fighting facilities for design standards and operations of emergency preparation equipments, to improve the regulations for fire protection system such as the sprinkler system, and to restrict the facilities having fire hazards.

A Study on the Revitalization of the Emergency Medical Services for a Aged Society - Based on Possible Solutions to Improve Early Response System for Geriatric Emergency Patients - (고령화 사회 구급서비스 활성화에 관한 연구 - 노인 응급환자 초기대응 시스템 개선방안 -)

  • Jung, Ji-Yeon;Hwang, Hee-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.99-104
    • /
    • 2008
  • As a part of improving early response system for senior emergency patients in rural areas in preparation for accelerated transition of Korea into aged society, this study seeks to make effective use of town broadcasting equipments and improve conventional educational ways for the first aid for senior people to boost up availability of private rescue personnel, so that it can contribute to improving capacity to early response to potential occurrence of emergency situations. In addition, this study focuses on profiling current activities of 119 geriatric Emergency Medical Services available in Korea, and also exploring possible ways to improve emergency services for senior safety which can play useful roles of social safeguard in imminent aged society as well as efficient ways to build up infrastructure for senior safety on the basis of opening up senior safety center.

A study on the development of emergency management program for railway fire safety improvement (철도화재 안전개선대책수립을 위한 위기관리프로그램 개발 연구)

  • Wang, Jong-Bae;Kwak, Sang-Log;Hong, Seon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.235-240
    • /
    • 2003
  • In this paper, the fire safety management plan and the emergency action program for the railway safety improvement were reviewed. In the fire safety management plan, a series of preventive methods answering to such as a smoke exhaust installation, a fire warning device and a guide inducement will be come into preparation. Also, the damage reducing methods such as complement of fire safety equipments, establishment of refuge & escape system, consolidation of real-time control on fire response and operation procedure will be required for early repressing fire and minimizing fatality.

  • PDF

A Study on Anti-Icing Technique for Weather-Tight Door of Ice-Strengthened Vessels (내빙선박용 풍우밀 문의 결빙방지 기법 연구)

  • Jeong, Seong-Yeob;Chun, Eun-Ji;Cho, Seong-Rak;Lee, Chun-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.6
    • /
    • pp.575-580
    • /
    • 2011
  • Icing problem of ice-strengthened vessels is an important issue when operating in low temperature environment and it can cause damage to deck machineries and emergency equipments. Many ice-strengthened vessels have since been constructed and operated in accordance with the ice class rules such as Det Norske Veritas (DNV), Russian Maritime Register of Shipping (RS), American Bureau of Shipping (ABS) and so on. Therefore winterization is defined as the preparation of a ship for safe operation. In this research, anti-icing performance tests of weather-tight door have been carried out at various temperature conditions($5^{\circ}C$, $-10^{\circ}C$, $-20^{\circ}C$, $-30^{\circ}C$, $-40^{\circ}C$) in the low temperature cold room facility and then, ambient temperature, specimen temperature, electric current and temperature of heating cable were measured during the test operations. This research describes the construction guidelines of weather-tight door based on anti-icing test results to apply to the full-scale vessels.