• Title/Summary/Keyword: Emergency power

Search Result 744, Processing Time 0.025 seconds

A study of SDN/SON-based emergency communications systemprovisioning for nuclear power plant under extreme natural disaster (극한 자연재해 상황 하의 SDN/SON 기반 원자력발전소 비상통신망 구축방안 연구)

  • Choi, Taesang;Yoon, Sangsik;Lee, Junkyung;Cho, Yongsu;Lee, Sangjin
    • KNOM Review
    • /
    • v.22 no.3
    • /
    • pp.31-39
    • /
    • 2019
  • This paper introduces our research results of SDN/SON-based emergeny communications system for nuclear power plant under extreme natural diaster like Fukusima nuclear power plant incident. In such a extreme situation, nuclear power plant operational staffs which do not have technical knowledge of network provisioning and operations have to deploy the emergency network. Thus our proposed system provides capabilities to provision an emergency network autonomically and enable voice and data services. It also describes our PoC system developed based on the proposed core technology and architecture with the results of system verification testing.

Suggestion of a New Writer's Guideline to Reduce Human Errors Found in the Emergency Operation Procedures of a Nuclear Power Plant (비상운전절차서 작성과정의 인적오류 저감을 위한 지침서 제안에 관한 연구)

  • Lee, Dhong-Ha;Jang, Tong-Il;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.129-138
    • /
    • 2010
  • Gori-I nuclear power plant has been examining the effectiveness and efficiency of the current emergency operation procedures from human factors viewpoint. Previous study showed that some mistakes that the procedures did not comply with the writers' guidelines. Reviewing the current writers' guidelines for emergency operating procedures revealed that they lack of some important human factors rules such as enumeration of switching conditions and detailed action requirements, definite expression for setup points, description for anticipated results, and recommendation for use of present tense, affirmative sentence and active voice. This study suggested a new classification system for the writers' guideline contents supplementing the deficiencies of the current emergency operation procedure text.

Development of a Task Analysis Method and Classification of Emergency Tasks for Human Error Analysis in Nuclear Power Plants (원자력발전소 오류분석을 위한 직무분석 방법의 개발 및 직무유형 분류)

  • 정원대;박진균;김재환
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.168-174
    • /
    • 2001
  • For human error analysis, the structure and situation of a task should be analyzed in advance. The paper introduces Structured Information Analysis (SIA) as a task analysis method for error analysis, and delineates the result of application on the emergency procedure of Korean Standard Nuclear Plants (KSNPs). From the task analysis about emergency procedure of KSNP, total 72 specific task goals were identified in the level of system function, and 86 generic tasks were classified from the viewpoint of physical sameness of the task description. Human errors are dependent on task types so that the result of task analysis would be used as a basis for the error analysis on the emergency tasks in nuclear power plants.

  • PDF

Analysis of the Thermoelectric Devices' Power Generation Performance for Utilizing the Waste Heat of LED Tunnel Lighting Module (LED터널등 모듈의 폐열활용을 위한 열전소자의 발전 성능 분석)

  • Jeong, Ji-Young;Her, In-Sung;Lee, Se-Il;Kim, Myeong-Ho;Yu, Young Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.1-6
    • /
    • 2015
  • In this paper, we propose the LED(Light-Emitting-Diode) emergency lighting in a tunnel by using the thermoelectric devices. To achieve high generated power, thermoelectric device should be have high Seebeck coefficient and small contact area. Also, we reveal that a moderate heatsink required for high generated power. From the waste heat of LED tunnel lighting module (25W), the generated power was 0.062W by thermoelectric device, and it could illuminate for 1hour after charge the battery of emergency lighting during about 101hours.

Study on the Safe Evacuation Management in a Power Supply Disturbed Emergency

  • Suzuki, Nobuyuki;OHASHI, Tsubasa;WHORLOW, James R
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.87-91
    • /
    • 2015
  • For construction projects it is imperative that site management gives the highest priority to planning safe site evacuation for all foreseeable emergencies, including earthquakes and typhoons which are often experienced in Japan. This is especially important and even more critical for high risk projects involving underground works, such as Tunneling & Pneumatic Caissons. Based on the safety regulation of underground works, a back-up power supply system must be provided during the construction period at all times. Often, fluorescent lamps with re-chargeable batteries are provided for infrequent emergency cases, however these have a questionable useable life span and thus need careful maintenance and periodical replacement. In this paper we focused on using the phosphorescence materials to indicate the evacuation direction. As a result, it was confirmed that the phosphorescence materials were considered useful in reducing panic and facilitating a controlled evacuation in the event of a total black-out due to power failure.

  • PDF

Optimization of the Design of Large Ducts with the Space Constraint in 500MW Power Plant (500MW 발전소에서 협소 공간 내 대형 덕트 설계의 최적화)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok;Cho, Yong-Ki
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.755-765
    • /
    • 2009
  • Some sections of the exhaust system to determine the shape of the duct is to suffer the difficulties by space constraints to install new equipment of the environment post-treatment for existing operation of the power plants. In this paper the large duct in flue gas desulfurization equipments of the 500MW coal-fired power plant on the current operation is numerically analyzed from induced draft fan exit to booster up fan inlet section which is in the narrow space of the exhaust system with four times bending and is connected to emergency duct to bypass the exhaust gas on the emergency operation. The procedure and method using computational fluid dynamics are proposed to maintain the stability of the guide vane with the uniform flow and a minimum pressure loss of exhaust gas in the case of normal and emergency operation between the direction of the flow of exhaust gas duct at different.

Suggestions to Improve the Effectiveness of National Radiological Emergency Response System (국내 방사능재난대응체계 실효성 제고를 위한 제언)

  • Moon, Joo Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.195-206
    • /
    • 2020
  • Although the national radiological emergency response system has been improved by incorporating lessons from the Fukushima nuclear power plant accident and recent domestic natural disasters, it has not fully incorporated these lessons. In addition, it cannot deal with a variety of aftermath of the radiological disaster. Even for the same disaster, the national emergency response system should comply with multiple domestic laws in our country. Furthermore, there are a few discrepancies between the articles of the domestic laws that the national radiological emergency response system should address. Therefore, this study investigates the characteristics of radiological disasters, examines articles on the domestic laws related to the national radiological emergency response system, and analyses the Japanese government's responses to the Fukushima nuclear power plant accident. Based on the results of the review, suggestions for the improvement of the national radiological emergency response system in terms of response organization and framework have been proposed in this study.

An Integrated Emergency Call System based on Public Switched Telephone Network for Elevators

  • Lee, Guisun;Ryu, Hyunmi;Park, Sunggon;Cho, Sungguk;Jeon, Byungkook
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.69-77
    • /
    • 2019
  • Today, most of elevators have an emergency call facility for emergency situations. However, if the network installed in the elevator is also out of power, it cannot be used for the elevator remote monitoring and management. So, we develop an integrated and unified emergency call system, which can transmit not only telephone call but also data signals using PSTN(Public Switched Telephone Network) in order to remote monitoring and management of elevators, even though a power outage occurs. The proposed integrated emergency call system to process multiple data such as voice and operational information is a multi-channel board system which is composed of an emergency phone signal processing module and an operational information processing module in the control box of elevator. In addition, the RMS(remote management server) systems based on the Web consist of a dial-up server and a remote monitoring server where manages the elevator's operating information, status records, and operational faults received via the proposed integrated and unified emergency call system in real time. So even if there's a catastrophic emergency, the proposed RMS systems shall ensure and maintain the safety of passengers inside the elevator. Also, remote control of the elevator by this system should be more efficient and secure. In near future, all elevator emergency call system need to support multifunctional capabilities to transmit operational data as well as phone calls for the safety of passengers. In addition, for safer elevators, it is necessary to improve them more efficiently by combining them with high-tech technologies such as the Internet of Things and artificial intelligence.

Human Performance Analysis of Emergency Tasks in Nuclear Power Plant (원자력발전소 비상직무에 대한 인적수행도 분석)

  • Jung, Won-Dae;Park, Jin-Kyun;Kim, Jae-Whan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.13-24
    • /
    • 2002
  • Reduction and prevention of human error is one of the major interests for the enhancement of system safety and availability in Nuclear Power Plants (NPPs). As human beings have become the weak point in the system safety, a systematic evaluation on human performance during emergency situation should be performed in advance to identify the potential vulnerability of human tasks. Though the data gathering and analysis from real field is an important precondition, there were no available data in nuclear field of korea. This paper presents the result of human performance analysis on emergency tasks in NNPs. Firstly, a task analysis was performed to identify the characteristics of operator tasks during emergency condition and to classify them into a set of generic emergency tasks. Secondly, simulation data were collected and analyzed for the emergency tasks using the full scope simulator of Younggwang NPPs. The analyzed human performance information cover the event diagnosis time, the execution time of each procedural step, observation parameters, typer of irrelevant response, pattern of communication among staffs, and so on. These performance data would be used for human reliability analysis and the research of human error as technical bases.

A Risk Impact Assessment According to the Reliability Improvement of the Emergency Power Supply System of a Nuclear Power Plant (원자력발전소 비상전력계통 강화 방안에 따른 리스크 영향 평가)

  • Jeon, Ho-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.224-228
    • /
    • 2012
  • According to the results of Probabilistic Safety Assessment(PSA) for a Nuclear Power Plant(NPP), an Emergency Power Supply(EPS) system has been considered as one of the most important safety system. Especially, the interests in the reliability of the EPS system have been increased after the severe accidents of Fukushima Daiichi. Firstly, we performed the risk assessment and the importance analysis of the EPS system based on the PSA models of the reference plant, which is the Korean standard NPP type. Considering a portable Diesel Generator(DG) system as the reliability reinforcement of the EPS system, we modified the PSA models and performed the risk impact assessment and the importance analysis. Although the reliability of the potable DG could be about 20% of the reliability of the alternative AC DG, we identified that Core Damage Frequency(CDF) was decreased by at least 4.6%. In addition, the risk impacts due to the unavailability of the EPS system on CDF were decreased.