• Title/Summary/Keyword: Emergency generator

검색결과 198건 처리시간 0.03초

Weak Feed 전력계통의 블랙스타트와 고조파 공진 사례연구 (A Case Study of Harmonic Resonance & Black Start in Weak Feed Power System)

  • 박영철;이은섭;손효수;이석현
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.40-50
    • /
    • 2016
  • In order to recover the power system during the wide power outage or power failure in the power plant, black start system should be properly operated without any problem. Especially power for black start in the geographically isolated areas of electric island is supplied from small emergency start-up generator, and loads are aux systems of gas turbines such as SFC(Static frequency converter). This paper introduces the international practices to overcome the voltage drop problem with harmonics of the system having the DC output such as SFC during black start in weak feed system and analyzes the relationship between house load inputs and harmonics. By varying the house load and input of power supply, this paper identified boundaries between weak feed and strong feed power. In order to verify the theory of stable condition in weak feed power system with DC output, house load is simulated using ETAP. Additionally MATLAB was used for harmonic analysis between the load inertia moment and non load inertia moment.

원자력발전소 안전등급 계통 적용을 위한 디지털 상용기기 품질검증 (Commercial Grade Item Dedication of Digital Devices for Safety-related System in Nuclear Power Plant)

  • 홍영희;배병환;박재현
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1637-1639
    • /
    • 2014
  • In the past, the analog protection relays have been widely used for the safety-related systems in the nuclear power plants due to their stability and reliability. Meanwhile, as the high performance digital system has been developed, the digital systems have been adopted in the non-safety systems. However, since the digital systems currently used in the non-safety systems were not developed according to Q-class standard, Commercial Grade Item Dedication (CGID) procedure should be performed in order to apply them to the safety-related system. The purpose of this paper is to describe the CGID procedure including the analysis of the hardware architecture as well as the software embedded in protective relay to apply to the emergency diesel generator in the nuclear power plant. The entire CGID procedure was performed strictly according to the international standard and regulations.

2004-2006년에 발생한 제주지역의 낙뢰 특성 및 풍력발전기에 미치는 낙뢰의 영향 (Characteristics of Lightning Occurred over Jeju Island for 2004-2006 and an Effect of Lightning on Wind Turbine Generator System)

  • 고경남;김경보;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.83-89
    • /
    • 2008
  • This paper presents the characteristics of lightning pver Jeju island and a case of emergency stop of a wind turbine due to lightning. Using the IMPACT ESP sensor to detect lightning, the data on lightning frequency, lightning strength, regional lightning event were obtained and analyzed in detail. The measurement period was for 3 years from 2004 to 2006. As a result, lightning occulted the most frequently in July and August. As for lightning strength, lightning with grades -4 to -6 and +3 to +5 occur ed more frequently. The eastern part of Jeju island had much more lightning frequency compared with the western part of it. Lightning with high grade occurred mainly in offshore site and the coastal region. Furthermore, the data on wind turbine stop caused by lightning was analyzed. Although wind turbine lightning damage was not much in this study, the investigation on lightning damage or lightning faults to a wind turbine should be conducted in Korea to increase availability of wind turbine.

철도 전자연동장치의 고신뢰화를 위한 실시간 전문가 시스템 (A Real-Time Expert System for the High Reliability of Railway Electronic Interlocking System)

  • 고윤석;최인선;권용훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1457-1463
    • /
    • 1999
  • This paper develops an real-time expert system for the electronic interlocking system. it obtains the higher safety by determining the railway interlocking strategy in order to prevent trains from colliding, and derailing in the viewpoint of veteran expert, considering the situation of station in real-time. The expert system determines the real-time interlocking strategy by confirming the interlocking relationships among signal facilities based on the interlocking knowledge base from input information such as signal, points, and it is implemented as the rule-based system in order to represented accurately and effectively the interlocking relationships. Especially in case of emergency the function which determines the rational route coordinating with IIKBAG on the workstation is designed in order to minimize the spreading effect. It is implemented in C computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the build and interface of the station structure database. And, the validity of the built expert system is proved by simulating the diversity cases which may occur in the real system for the typical station model.

  • PDF

부유식 석유생산.저장.하역선박의 소음해석 (A Noise Prediction of Floating, Production, Storage and Offloading(FPSO))

  • 김영현;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

지오소셜 정보 기반 개인 맞춤형 경보 시스템 원형 구현 (Prototype Implementation of a Personalized Warning Notification System based on Geosocial Information)

  • 부둑 티엡;뉘엔 반 퀴엣;김경백
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.332-334
    • /
    • 2015
  • Nowadays a disaster event such as a building on fire, an earthquake or typhoon could occur any time, and any where. In such event, a warning notification system is a vital tool to send warning notifications to at-risk people in advance and provide them useful information to escape the dangerous area. Though some systems have been proposed such as emergency alert system using android, SMS or P2P overlay network, these works mainly focus on a reliable message distribution methods. In this work, we introduce a full prototype implementation of a personalized warning notification system based on geosocial information, which generates a personalized warning message for each user and delivers the messages through email or an android application. The system consists of four main modules: a web interface, database, a knowledge-based message generator, and message distributor. An android application is also created for user to receive warning messages on their smart phone. The prototype has been demonstrated successfully with a building-on-fire scenario.

하이브리드 전기 추진 시스템의 전력 제어에 관한 연구 (A Study on Power contorl for Hybrid electric propulsion system)

  • 오진석;조관준;함연재;배수영;정성영
    • 한국항해항만학회지
    • /
    • 제32권10호
    • /
    • pp.765-770
    • /
    • 2008
  • 본 논문은 하이브리드 전기 추진 시스템의 전력 제어에 관한 연구를 수행하였다. 하이브리드 전기 추진 시스템은 기본적으로 발전기와 축전지 전원을 이용하여 선박을 추진하는 시스템이다. 하이브리드 추진 시스템은 공급되는 전력을 최소화하기 위한 제어 알고리즘으로 동작한다. 본 논문에서는 하이브리드 전기 추진 시스템의 효율을 증가시키기 위한 축전지 충전 알고리즘을 제안한다. 실험을 통하여 제어 알고리즘이 하이브리드 전기 추진 시스템에서 정상적으로 동작하는 것을 알 수 있었다.

소프트 절환이 가능한 계통 연계형 CTTS 시스템 구성에 관한 연구 (A Study on System Configuration of Grid-connected CTTS System with Soft Switching)

  • 이형묵;양지훈;이정환;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.361-368
    • /
    • 2018
  • This paper proposes a grid - connected CTTS system that can be soft switched to meet the government's effective resource allocation policy for emergency generator. In order to eliminate the system instability caused by the large inrush current generation in the system switching, a new virtual rotation coordinate method for the dissimilar power source is proposed. The proposed virtual rotation coordinate method improves the voltage detection accuracy of the voltage difference of the dissimilar power supply, and it is proved that the synchronous switching characteristic is excellent. In addition, zero current and system stabilization can be achieved by realizing zero current when blocking CTTS with instantaneous reactive power control. Simulation was carried out to verify the validity of the proposed method, and the 500[kVA] system was fabricated and verified to demonstrate the superiority of the proposed method.

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

배전계통 복원력 확보 및 복원 전략에 따른 정전비용분석에 관한 연구 (A Study on Power Outage Cost Analysis according to Distribution System Resilience and Restoration Strategies)

  • 서세훈;박현곤
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.18-24
    • /
    • 2023
  • Severe natural disasters and man-made attacks such as terrorism are causing unprecedented disruptions in power systems. Due to rapid climate change and the aging of energy infrastructure, both the frequency of failure and the level of damage are expected to increase. Resilience is a concept proposed to respond to extreme disaster events that have a low probability of occurrence but cause enormous damage and is defined as the ability of a system to recover to its original function after a disaster. Resilience is a comprehensive indicator that can include system performance before and after a disaster and focuses on preparing for all possible disaster scenarios and having quick and efficient recovery actions after an incident. Various studies have been conducted to evaluate resilience, but studies on economic damage considering the duration of a power outage are scarce. In this study, we propose an optimal algorithm that can identify failures after an extreme disaster and restore the load on the distribution system through emergency distributed power generation input and system reconfiguration. After that, the cost of power outage damage is analyzed by applying VoLL and CDF according to each restoration strategy.