• Title/Summary/Keyword: Emergency evacuation

Search Result 298, Processing Time 0.026 seconds

A Cervical Epidural Hematoma Caused by Ruptured Arteriovenous Malformation Presenting as a Brown-Sequard and Horner's Syndrome - A Case Report - (Brown-Sequard 증후군과 Horner씨 증후군으로 발현된 동정맥 기형 파열로 인한 경추 경막외 혈종 - 증례보고 -)

  • Jeon, Een-Ho;Song, Jun-Hyeok;Park, Hyang-Kwon;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.144-148
    • /
    • 2001
  • We report a rare case of Brown-Sequard syndrome associated with Horner's syndrome in cervical epidural hematoma caused by a ruptured arteriovenous malformation. A 54-year-old man developed sudden sharp neck pain, radiating to the interscapular area. Within hours, left side hemiplegia and decreased tactile sense and loss of contralateral pain sense ensued. Emergency cervical magnetic resonance image showed an epidural hematoma over the cervico-thoracic junction. The hematoma was located in the left posterolateral area of the cervical spinal canal. Emergent decompressive laminectomy and an evacuation of the hematoma were performed. A tangled soft tissue mass found in the hematoma was proven to be an arteriovenous malformation. To the authors, knowledge, this might be the first case of a Brown-Sequard syndrome associated with Horner's syndrome caused by ruptured cervical epidural arteriovenous malformation.

  • PDF

Cervical Epidural Hematoma Caused by Ruptured Arteriovenous Malformation - Case Report - (관동정맥기형 파열로 인한 경추강내의 경막외 혈종 - 증례보고 -)

  • Min, Hyung-Sik;Song, Jun-Hyeok;Kim, Myung-Hyun;Park, Hyang-Kwon;Kim, Sung-Hak;Shin, Kyu-Man;Park, Dong-Been
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.396-401
    • /
    • 2000
  • We report a case of spontaneous cervical epidural hematoma caused by a pure epidural arteriovenous malformation. A 22-year-old woman developed a sudden quadriplegia after a vigourous physical therapy including multiple acupunctures for her neck pain. Emergency cervical magnetic resonance image showed an epidural hematoma in her cervicothoracic junction. Emergent decompressive laminectomy and an evacuation of the hematoma were performed. A soft tissue mass found in the hematoma was proven to be an arteriovenous malformation. Postoperatively, the patient experienced some complications. However, she recovered completely from the motor weakness.

  • PDF

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.

Analysis of Patients with Cerebral Aneurysm Rupture Treated by Coil Embolization : Retrograde Study in Single Institute (코일색전술로 치료받은 뇌동맥류 파열 환자 분석 : 단일기관 후향적 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.357-363
    • /
    • 2019
  • To the basic information of patients with subarachnoid hemorrhage due to rupture of cerebral aneurysm treated with coil embolization, and to identify the general trend of treatment through classification according to hospitalization route, residence distribution, location and size of cerebral aneurysm, and procedure. A total of 164 patients with ruptured cerebral aneurysms treated with coil embolization were 54(32.9%) males and 110(67.1%) females. The sex and frequency of occurrence by age group were the most in 50s(31.3%), and among them, females were the most. The hospitalization route was the most common in 122(74.4%) people who were admitted to the emergency room through 119 evacuation, 79(48.2%) patients lived in where hospitals belong to the hospital. The season had 23(14%) in December, 18(11%) in January, 15(9.1%) in February, and the anterior circulation was 153(93%). The largest size was 5-7 mm found in 63(38.4%) patients. Patients underwent initial coil embolization for subarachnoid hemorrhage due to cerebral aneurysm rupture treated more patients than the incidence of the population. As a result of cerebral aneurysm rupture was seasonally affected, and winter occurs more frequently, female than male, age 50 is most common, and ruptured cerebral aneurysm is 5-7 mm in size.

Failure Mode of Structural Components Considering Column Axial Forces and Partial Masonry Infills for School Buildings Constructed in the 1980s (기둥 축력과 조적허리벽을 고려한 1980년대 학교교사 구조요소의 파괴모드 평가)

  • Jeong, Su-Hyeon;Choi, Myeong-Ho;Lee, Chang-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2022
  • As earthquakes have increased in Korea recently, people are paying attention to the seismic performance of buildings built in the past. Many school buildings in Korea were built based on standard drawings before the seismic design was applied. However, since school buildings are often designated as emergency evacuation facilities in case of disasters such as earthquakes, seismic evaluation and retrofit must be done quickly. This study investigated the failure modes among structural components (beams, columns, and joints), focusing on 1980s standard drawings for school buildings. The effects of column axial force, partial masonry infills, and different material strengths for concrete and rebar were considered for detailed evaluation. As a result, most of the joints were found to be the weakest among structural components. Column axial forces tended to make the joints more vulnerable, and partial masonry infills increased the possibility of joint failure and shear failure in columns.

Radiation Distribution Around Fukushima Daiichi Nuclear Power Station Decade After the Accident

  • Yukihisa Sanada;Miyuki Sasaki;Hiroshi Kurikami;Fumiya Nagao;Satoshi Mikami
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.95-114
    • /
    • 2023
  • During the decades after the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, ambient dose rates have markedly decreased when compared to those at the early state of the accident. Government projects have been continuously conducted by surveying the ambient dose rate and radiocesium distributions. Airborne surveys using crewed helicopters and unmanned aerial vehicles (UAVs) are the best methods for obtaining an overall picture of the distribution. However, ground-based surveys are required for accurate measurements near the population. The differences between these methods include the knowledge of the post depositional behavior of radionuclides in land use. The survey results form the basis for policy decisions such as lifting evacuation zones, decontamination, and other countermeasures. These surveys contain crucial findings regarding post-accident responses. This paper reviews the survey methods of government projects and current situation around the FDNPS. The visualization methods and databases of ambient dose rates are also reviewed to provide information to the population.

A Study on the Development of Cabin Safety Learning Contents Using Virtual Reality Technology (VR) (가상현실 기술을 활용한 객실안전 학습 콘텐츠 개발 연구)

  • Ha-Young Kim;Jung-Hwa You
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.2
    • /
    • pp.25-37
    • /
    • 2023
  • The purpose of this study is to develop and technically implement the design and scenario of cabin safety contents for virtual reality (VR)-based cabin safety learning for aviation service majors. The process for developing VR cabin safety learning contents consisted of a total of four stages: learning stage, research stage, verification stage, and application stage. The cabin safety scenario items for the production of VR learning contents reflected the occurrence of an emergency, the procedure for survival from impact, and the evacuation procedure from the aircraft as the core. For the technical implementation of learning contents, modeling work is conducted by checking scenario reviews, types and numbers of objects related to equipment and facilities, and items of interaction. In addition, the connection work with the actual metaverse platform is carried out to enable the utilization of the manufactured facilities and equipment objects. Finally, application tests were carried out to reconfirm supplementary items.

Development of distributed inundation routing method using SIMOD method (SIMOD 기법을 이용한 분포형 침수 추적 기법 개발)

  • Lee, Suk Ho;Lee, Dong Seop;Kim, Jin Man;Kim, Byung Sik
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.579-588
    • /
    • 2016
  • Changes in precipitation due to climate change is made to induce the local and intensive rainfall, it is increasing damage caused by inland inundation. Therefore, it requires a technique for predicting damage caused by flooding. In this study, in order to determine whether this flood inundated by any route when the levee was destroyed, Which can simulate the path of the flood inundation model was developed for the SIMOD (Simplified Inundation MODel). Multi Direction Method (MDM) for differential distributing the adjacent cells by using the slope and Flat-Water Assumption (FWA)-If more than one level higher in the cell adjacent to the cell level is the lowest altitude that increases the water level is equal to the adjacent cells- were applied For the evaluation of the model by setting the flooding scenarios were estimated hourly range from the target area. SIMOD model can significantly reduce simulation time because they use a simple input data of topography (DEM) and inflow flood. Since it is possible to predict results within minutes, if you can only identify inflow flood through the runoff model or levee collapse model. Therefore, it could be used to establish an evacuation plan due to flooding, such as EAP (Emergency Action Plan).

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

An Intelligent CCTV-Based Emergency Detection System for Rooftop Access Control Problems (옥상 출입 통제 문제 해결을 위한 지능형 CCTV 기반 비상 상황 감지 시스템 제안)

  • Yeeun Kang;Soyoung Ham;Seungchae Joa;Hani Lee;Seongmin Kim;Hakkyong Kim
    • Convergence Security Journal
    • /
    • v.24 no.1
    • /
    • pp.59-68
    • /
    • 2024
  • With advancements in artificial intelligence technology, intelligent CCTV systems are being deployed across various environments, such as river bridges and construction sites. However, a conflict arises regarding the opening and closing of rooftop access points due to concerns over potential accidents and crime incidents and their role as emergency evacuation spaces. While the relevant law typically mandates the constant opening of designated rooftop access points, closures are often tacitly permitted in practice for security reasons, with a lack of appropriate legal measures. In this context, this study proposes a detection system utilizing intelligent CCTV to respond to emergencies that may occur on rooftops. We develop a system based on the YOLOv5 object detection model to detect assault and suicide attempts by jumping, introducing a new metric to assess them. Experimental results demonstrate that the proposed system rapidly detects assault and suicide attempts with high accuracy. Additionally, through a legal analysis of rooftop access point management, deficiencies in the legal framework regarding rooftop access and CCTV installation are identified, and improvement measures are proposed. With technological and legal improvements, we believe that crime and accident incidents in rooftop environments will decrease.