• Title/Summary/Keyword: Emergency Light

Search Result 129, Processing Time 0.027 seconds

Diminishing Procedural Boundaries in International Arbitration

  • Pareek, Abha
    • Journal of Arbitration Studies
    • /
    • v.23 no.4
    • /
    • pp.123-138
    • /
    • 2013
  • The surge of cross border trade and transactions has seen international arbitration fast emerging as the preferred mode of dispute resolution. This phenomenon is especially remarkable in the Asian region. The Singapore International Arbitration Centre ("SIAC") aspires to contribute to this growth as one of the leading arbitral institutions. The objective of this article is to provide an insight into the key features of SIAC Rules. This article has been divided into two parts; the first part discusses how the SIAC Rules are helpful in building bridges in international arbitration between the common law and civil law systems. We have attempted to throw light on how the SIAC Rules may be tailored by the parties to bring about a harmonization in the common law and civil law practices in the conduct of the arbitration proceedings. In the second part of the article, we discuss the two most popular procedures introduced in the SIAC Rules in 2010 i.e. 'Emergency Arbitration' and 'Expedited procedures'. The emergency arbitration provisions enable a party to obtain order(s)/award for urgent interim relief(s) upon commencement of arbitral proceedings but pending the constitution of the main Tribunal. The expedited Procedure provisions give parties the option of having their disputes determined in six (6) months from the date of the constitution of the tribunal.

  • PDF

An Experimental Study on Performance Improvement for Exhaust Heat Recovery Ventilation System in a Lightweight Wall (벽체매립형 폐열회수 환기시스템의 열회수 성능 향상에 관한 실험적 연구)

  • Chung, Min-Ho;Oh, Byung-Kil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.61-66
    • /
    • 2014
  • Exhaust heat recovery ventilation systems conserve energy through enthalpy recovery between air intake and exhaust, and they are being increasingly used. An exhaust heat recovery ventilation system can be installed in the ceiling of a balcony or emergency evacuation space. However, in the case of fire, the emergency evacuation space has to by law remain as empty space, and therefore, a ventilation system can't be installed in an emergency evacuation space. Therefore, the need for a proper installation space for a ventilation system is emphasized. In this study, to install a heat recovery ventilation system in a lightweight wall, a heat exchanger was assembled of thickness below 140 mm. The efficiency of heat recovery was analyzed through performance experiment, in the case of the cooling and heating mode. The heat recovery efficiency increases when the surface area is increased, by using closer channel spacing in the heat exchanger, or by increasing the size of the heat exchanger.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Stunting and Gut Microbiota: A Literature Review

  • Jessy Hardjo;Nathasha Brigitta Selene
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.3
    • /
    • pp.137-145
    • /
    • 2024
  • Stunting, a condition characterized by impaired growth and development in children, remains a major public health concern worldwide. Over the past decade, emerging evidence has shed light on the potential role of gut microbiota modulation in stunting. Gut microbiota dysbiosis has been linked to impaired nutrient absorption, chronic inflammation, altered short-chain fatty acid production, and perturbed hormonal and signaling pathways, all of which may hinder optimal growth in children. This review aims to provide a comprehensive analysis of existing research exploring the bidirectional relationship between stunting and the gut microbiota. Although stunting can alter the gut microbial community, microbiota dysbiosis may exacerbate it, forming a vicious cycle that sustains the condition. The need for effective preventive and therapeutic strategies targeting the gut microbiota to combat stunting is also discussed. Nutritional interventions, probiotics, and prebiotics are among the most promising approaches to modulate the gut microbiota and potentially ameliorate stunting outcomes. Ultimately, a better understanding of the gut microbiota-stunting nexus is vital for guiding evidence-based interventions that can improve the growth and development trajectory of children worldwide, making substantial strides toward reducing the burden of stunting in vulnerable populations.

Bio-Medical Data Transmission System using Multi-level Visible Light based on Resistor Ladder Circuit (저항 사다리 회로 기반의 다중레벨 가시광을 이용하는 의료 데이터 전송 시스템)

  • An, Jinyoung;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • In this study, a multilevel visible light communication (VLC) system based on resistor ladder circuit is designed to transmit medical data. VLC technology is being considered as an alternative wireless communication due to various advantages such as ubiquity, license free operation, low energy consumption, and no radio frequency (RF) radiation characteristics. With VLC even in places where traditional RF communication (e.g., Wi-Fi) is forbidden, significant bio-medical signal including the electrocardiography (ECG) and photoplethysmography (PPG) data can be transmitted. More lives could be saved anywhere by this potential advantage of VLC with a fast emergency response time. A multilevel transmission scheme is adopted to improve the data capacity with keeping simplicity, where data transmission rate can increase by log2m times (m is the number of voltage levels) than that of conventional VLC transmission based on on/off keying. In order to generate multi-amplitudes, resistor ladder circuit, which is a basic principle of digital to analog convertor, is employed, and information is transferred through LED (Light-Emitting Diode) with different voltage level. In the receiver side, multilevel signal is detected by optical receiver including a photo diode. Then, the collected data are analyzed to serve the necessary medical care to the concerned patient.

Pneumatosis Cystoides Intestinales and Portomesenteric Venous Gas following Anticholinesterase Pesticide Poisoning (항콜린에스테라아제 살충제 음독 후 발생한 창자벽공기낭증과 문맥장간막정맥가스 1례)

  • Lee, Suk Hee;Lee, Kyung-Woo;Jung, Jin Hee
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.1
    • /
    • pp.56-59
    • /
    • 2017
  • Pneumatosis cystoides intestinalis and portomesenteric venous gas are uncommon radiological findings, but are found commonly in cases of bowel ischemia, or as a result of various non-ischemic conditions. A 72-year-old man visited an emergency center with altered mental status 2 hours after ingestion of an unknown pesticide. On physical examination, he showed the characteristic hydrocarbon or garlic-like odor, miotic pupils with no response to light, rhinorrhea, shallow respiration, bronchorrhea, and sweating over his face, chest and abdomen. Laboratory results revealed decreased serum cholinesterase, as well as elevated amylase and lipase level. We made the clinical diagnosis of organophosphate poisoning in this patient based on the clinical features, duration of symptoms and signs, and level of serum cholinesterase. Activated charcoal, fluid, and antidotes were administered after gastric lavage. A computerized tomography scan of the abdomen with intravenous contrast showed acute pancreatitis, poor enhancement of the small bowel, pneumatosis cystoides intestinalis, portomesenteric venous gas and ascites. Emergent laparotomy could not be performed because of his poor physical condition and refusal of treatment by his family. The possible mechanisms were believed to be direct intestinal mucosal damage by pancreatic enzymes and secondary mucosal disruption due to bowel ischemia caused by shock and the use of inotropics. Physicians should be warned about the possibility of pneumatosis cystoides intestinalis and portomesenteric venous gas as a complication of pancreatitis following anticholinesterase poisoning.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.

Electro-Luminescent Display(ELD) Systems for the Cave Illumination

  • Oh, Jong-Woo
    • Journal of the Speleological Society of Korea
    • /
    • no.85
    • /
    • pp.1-14
    • /
    • 2008
  • Electroluminescent Display(ELD) will be the innovative ideas to replace existed electricity illumination systems that consider to under effectiveness and environmental pollution generators in the commercial caves because ELD has less heat and low electricity consumption by the new illumination materials. Characteristics of the ELD are as following: it is a proper matter for the small merchandise ads due to its thickness is only below 3oo micoron, electricity consumption of ELD is less (1/3) than LED, ELD that is a whole face illumination system is much brighter than LED that is a dot illumination system, ELD is longer life than others due to its less light generation systems, ELD is any problems to bend, and it is a best device to use a light board ads. ELD has advantages on conservation of cave biosystems and reduce pollution when ELD is installed in touring spots and emergency corridors of weak illuminated cave internal areas by less heating and low electricity consumption using the indirect illumination of the ELD. Therefore when the high technologic ELD is installed in the commercial caves in Korea, it will be innovating cave environmental systems, saving budgets, and increasing tours.

A Case Study for the 1st Double-level Tunnel for Light vehicle in Urban Area in Korea (국내 최초 소형차 전용 도심지 대심도 복층터널 설계 사례)

  • Kim, Gyoung-Hun;Choi, Jun-Dong;Jun, Duk-Chan;Shin, Il-Jae;Sim, Dong-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1302-1313
    • /
    • 2010
  • The west express way is notorious for extremely heavy traffic area in the west of Seoul, South Korea. Hence, the city government recently initiated a new underground BTO (Build-Transfer-Operate) road project to solve traffic congestion and a high construction cost. The proposed underground express road being designed is the first double-level tunnel ever designed in South Korea and using Conventional tunnelling method (NATM). A total length of tunnel for light vehicles is 10.91km long including both open cut structures and concrete lining with middle-deck in bored tunnel. There are also 4 ventilation shafts for ventilation and evacuation on emergency. Many design issues had been aroused during the preliminary design phase and detail design phase is currently going on. This paper discusses design focuses including excavation methods, ground water issues, a deck slab installation, and a construction cost etc. for the double level road tunnel design of urban area.

  • PDF