• Title/Summary/Keyword: Embolization, Coil

Search Result 174, Processing Time 0.025 seconds

A Case of Bronchial Artery Aneurysm Demonstrating Hilar Mass (폐문부 종괴로 관찰된 기관지 동맥류 1예)

  • Hong, Seong-Ah;Ha, Tae-Hoon;Lyu, Ji-Won;Kim, Yang-Ki;Lee, Young-Mok;Kim, Ki-Up;Uh, Soo-taek;Noh, Hyung-Jun;Kim, Yong-Jae;Goo, Dong-Erk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.62-66
    • /
    • 2007
  • A bronchial artery aneurysm is a rare condition, which needs optimal treatment due to the possibility of a life-threatening hemorrhage by rupture. The surgical removal of the aneurysm is the standard treatment. However, there are a few reports of coil embolization with a transcatheter. A 69 year-old man was referred for a further evaluation of a mass in the right hilum on chest radiography. He denied any respiratory symptoms. A chest CT scan showed a $3{\times}3{\times}4.5cm$ sized vascular mass with strong contrast enhancement on the right hilar area that originated from the bronchial artery. On the angiogram, the bronchial artery originated from the descending thoracic aorta at the T8 level. A bronchial artery aneurysm was catheterized selectively. and embolized successfully with a coil. After coil embolization, the selective bronchial arteriography confirmed complete occlusion. We report this case of bronchial aneurysm that was treated successfully with coil embolization.

A Case of Rasmussen Aneurysm Treated by Pulmonary Arterial Embolization (폐동맥색전술로 치료된 Rasmussen 동맥류 1예)

  • Park, Sung-Oh;Ko, Hyuk;Kim, Su-Hee;Park, Wan;Lee, Deck-Hee;Ryul, Dae-Sik;Jung, Bock-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • A 42 year-old male with a history of multidrug-resistant pulmonary tuberculosis suddenly developed massive hemoptysis. Embolization of a bronchial artery branch and the collateral systemic arteries did not resolve the recurrent bleeding. Spiral computerized tomography(spiral CT) of the chest showed contrast enhanced nodules within a large cavity at the left lower lobe in the arterial phase suggesting a Rasmussen aneurysm. A pulmonary angiogram showed abnormal vascular nodules at that site. Coils were deployed at both the proximal and distal vessels of this aneurysmal sac for embolization. Transcatheter arterial embolization is a safe and effective means of controlling bleeding from this pulmonary arterial pseudoaneurysm. Here we report a case of a Rasmussen aneurysm diagnosed by spiral CT, which was successfully treated by pulmonary arterial embolization with a coil.

  • PDF

Endovascular Treatment of "Kissing Aneurysms" at the Anterior Communicating Artery

  • Suh, Sang-Jun;Kang, Dong-Gee;Ryu, Kee-Young;Cho, Jae-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.3
    • /
    • pp.163-165
    • /
    • 2008
  • Kissing aneurysms are the rare type of multiple aneurysms. They are adjacent aneurysms of different origin arteries in the same region, which require great care in diagnosis and treatment. We report a case of kissing aneurysms at the anterior communicating artery (AcomA) which were treated by endovascular coil embolization.

Effect of Heat Treatment on Properties of Tungsten Embolization Coils (텅스텐 색전코일의 특성에 미치는 열처리 효과)

  • Son, Ung-Hui;Hong, Sun-Hyeong;Sin, Gyeong-Min;Lee, Yun-Sin;Park, Jae-Hyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.333-339
    • /
    • 1998
  • The effect of heat treatment conditions on the properties of tungsten(W) embolization coils has been evaluated. The W embolization coils were fabricated by coiling the primary W coil with a diameter of 30.mm on a alumina rod mandrel with a diameter of 2.92mm. The secondary coils were then heat treated at 475$^{\circ}C$and 600$^{\circ}C$ for various heat treatment time ranging from 5 minutes to 36hours. The pitch distance, diameter and shape retention capability of the W embolization coils were characterized after the heat treatment. The pitch distance of the W embolization coils increased with the heat treatment time. The diameter of W emboliazation coils decreased continuously with heat treatment time. The shape retention capability of the W embolization coils increased with the heat treatment time due to an increase in elasticity by formation of tungsten oxide film on W coil surface during the heat treatment. The heat treatment condition of W embolization Col at 600$^{\circ}C$ for 20 minute was considered desirable based on the optimization of the shape retention capability, pitch distance and secondary coil diameter after heat treatment.

  • PDF

Treatment of a Carotid-Cavernous Sinus Fistula via the Superior Ophthalmic Vein Approach: A Case Report (상안정맥을 이용한 해면정맥동루의 색전술 치험례)

  • Moon, In-Sun;Shin, Han-Kyung;Kim, Dong-Il
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.116-119
    • /
    • 2010
  • Purpose: Arteriovenous fistulas that involve the cavernous sinus often produce ophthalmologic symptoms and signs. Transvenous endovascular access is the method of choice for a carotid-cavernous sinus fistula. The superior ophthalmic vein is a safe and reasonable alternative route for the transvenous embolization of carotid-cavernous sinus fistula. We report a case of the embolization of a carotid-cavernous sinus fistula using the superior ophthalmic vein approach. Methods: A 58 year old female had conjunctival congestion, periocular pain and diplopia with a 2 month duration. Diagnostic orbital CT, brain MRI and cerebral angiography revealed a carotid-cavernous sinus fistula. The fistula occlusion was treated by coil embolization using the superior ophthalmic vein approach. Results: The initial presenting symptoms, conjunctival congestion, periocular pain and diplopia, decreased after surgery. Coil embolization via the superior ophthalmic vein approach was difficult because of the venous tortuosity and friability. During the follow up period, the patient was in a good condition without complications. Conclusion: Surgical exposure of the superior ophthalmic vein provides direct venous access to the cavernous sinus as well as an effective and safe treatment approach. The cooperation of the plastic surgeon and interventionist is a factor in successful treatment.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Influence of Clinical and Anatomic Features on Treatment Decisions for Anterior Communicating Artery Aneurysms

  • Choi, Jae-Hyung;Kang, Myung-Jin;Huh, Jae-Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.2
    • /
    • pp.81-88
    • /
    • 2011
  • Objective : The purpose of this study was to analyze the clinical and anatomic features involved in determining treatment modalities for anterior communicating artery (AcoA) aneurysms. Methods : The authors retrospectively evaluated 112 AcoA aneurysms with pretreatment clinical features including age, Hunt and Hess grade, medical or neurological comorbidity, and anatomical features including aneurysm size, neck size, dome-to-neck ratio, vessel incorporation, multiple lobulation, and morphologic scoring system. Post-treatment clinical results were classified according to the Glasgow Outcome Scale, and anatomic results in coiled patients were classified according to the modified Raymond scale. Using multivariate logistic regression, the probabilities for decision making between surgical clipping and coil embolization were calculated. Results : Sixty-seven patients (60%) were treated with surgical clipping and 45 patients (40%) with endovascular coil embolization. The clinical factor significantly associated with treatment decision was age (${\geq}$65 vs. <65 years) and anatomical factors including aneurysm size (small or large vs. medium), dome-to-neck ratio (<2 vs. ${\geq}$2), presence of vessel incorporation, multiple lobulation, and morphologic score (${\geq}$2 vs. <2). In multivariate analysis, older patients (age, 65 years) had significantly higher odds of being treated with coil embolization relative to clipping (adjusted OR=3.78; 95% CI, 1.39-10.3; p=0.0093) and higher morphological score patients (${\geq}$2) had a higher tendency toward surgical clipping than endovascular coil embolization (OR=0.23; 95% CI, 0.16-0.93; p=0.0039). Conclusion : The optimal decision for treating AcoA aneurysms cannot be determined by any single clinical or anatomic characteristics. All clinical and morphological features need to be considered, and a collaborative neurovascular team approach to AcoA aneurysms is essential.

Treatment Outcomes with Selective Coil Embolization for Large or Giant Aneurysms : Prognostic Implications of Incomplete Occlusion

  • Jo, Kyung Il;Yang, Na-Rae;Jeon, Pyoung;Kim, Keon Ha;Hong, Seung-Chyul;Kim, Jong Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • Objective : The objectives of this study were to evaluate the immediate and long-term efficacy and safety of coil embolization for large or giant aneurysms. Methods : One hundred and fifty large or giant aneurysm cases treated with endovascular coil embolization between January 2005 and February 2014 at a single institute were included in this study. Medical records and imaging findings were reviewed. Statistical analysis was performed to evaluate prognostic factors associated with major recurrence (major recanalization or rupture) and delayed thromboembolism after selective coil embolization. Results : Procedure-related symptomatic complications occurred in five (3.3%) patients. The mean clinical and radiological follow-up periods were 38 months (range, 2-110) and 26 months (range, 6-108), respectively. During the follow-up period, the estimated recurrence rate was 4.6% per year. Multivariate analysis using Cox regression showed the degree of occlusion to be the only factor associated with recurrence (p=0.008, hazard ratio 3.15, 95% confidence interval 1.34-7.41). The patient's history of rupture in addition to the size and location of the aneurysm were not associated with recurrence in this study. Delayed infarction occurred in eight cases, and all were incompletely occluded. Conclusion : Although immediate postprocedural safety profiles were reasonable, longterm results showed recanalization and thromboembolic events to occur continuously, especially in patients with incomplete occlusion. In addition, incomplete occlusion was associated with delayed thromboembolic complications. Patients with incomplete occlusions should be followed carefully for delayed recurrence or delayed thromboembolic events.

Endovascular Treatment of Wide-Necked Intracranial Aneurysms : Techniques and Outcomes in 15 Patients

  • Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • Objective : It is technically difficult to treat wide-necked intracranial aneurysms by the endovascular method. Various tools and techniques have been introduced to overcome the related technical limitations. The purpose of this study was to evaluate the radiologic and clinical results of widenecked intracranial aneurysm treatment using the endovascular method. Methods : Fifteen aneurysms in 15 patients were treated by the endovascular method from October 2009 to August 2010. Seven patients presented with subarachnoid hemorrhage (SAH), seven patients had unruptured aneurysms, and one patient had an intracerebral hemorrhage and intraventricular hemorrhage due to an incompletely clipped aneurysm. The mean dome-to-neck ratio was 1.1 (range, 0.6-1.7) and the mean height-to-neck ratio was 1.1 (range, 0.6-2.0). We used double microcatheters instead of a stent or a balloon for the first trial. When we failed to make a stable coil frame with two coils, we used a stent-assisted technique. Results : All aneurysms were successfully embolized. Eleven aneurysms (73%) were embolized by the double microcatheter technique without stent insertion, and four aneurysms (27%) were treated by stent-assisted coil embolization. One case had subclinical procedure-related intraoperative hemorrhage. Another case had procedure-related thromboembolism in the left distal anterior cerebral artery. During the follow-up period, one patient (7%) had a recanalized aneurysmal neck 12 months after coil embolization. The recurrent aneurysm was treated by stent-assisted coil embolization. Conclusion : We successfully treated 15 wide-necked intracranial aneurysms by the endovascular method. More clinical data with longer follow-up periods are needed to establish the use of endovascular treatment for wide-necked aneurysm.

Predictor and Prognosis of Procedural Rupture during Coil Embolization for Unruptured Intracranial Aneurysm

  • Lee, Kyung Min;Jo, Kyung Il;Jeon, Pyoung;Kim, Keon Ha;Kim, Jong-Soo;Hong, Seung-Chyul
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.1
    • /
    • pp.6-10
    • /
    • 2016
  • Objective : The objectives of this study was to determine the incidence and outcomes of procedural rupture (PR) during coil embolization of unruptured intracranial aneurysm (UIA) and to explore potential risk factors. Methods : This retrospective study evaluated 1038 patients treated with coil embolization between January 2001 and May 2013 in a single tertiary medical institute. PR was defined as evidence of rupture during coil embolization or post procedural imaging. The patient's medical records were reviewed including procedure description, image findings and clinical outcomes. Results : Twelve of 1038 (1.1%) patients showed PR. Points and time of rupture were parent artery rupture during stent delivery (n=2), aneurysm rupture during filling stage (n=9) and unknown (n=1). Two parent artery rupture and one aneurysm neck rupture showed poor clinical outcomes [modified Rankin Scale (mRs) >2] Nine aneurysm dome rupture cases showed favorable outcomes ($mRS{\leq}2$). Location (anterior cerebral artery) of aneurysm was associated with high procedural rupture rate (p<0.05). Conclusion : The clinical course of a patientwith procedural aneurysm rupture during filling stage seemed benign. Parent artery and aneurysm neck rupture seemed relatively urgent, serious and life threatening. Although the permanent morbidity rate was low, clinicians should pay attention to prevent PR, especially when confronting the anterior cerebral artery aneurysm.