• Title/Summary/Keyword: Embolic Protection Device

Search Result 5, Processing Time 0.019 seconds

Thrombectomy of Femoro-Femoral Bypass Graft Occlusion Using the AngioJet Rheolytic Thrombectomy System and Embolic Protection Device: A Case Report (대퇴-대퇴동맥 우회 인조혈관 폐색에서 AngioJet Rheolytic Thrombectomy System과 색전보호기구를 이용한 혈전제거술: 증례 보고)

  • Han Sol Kang;Sangjoon Lee;Soon-Young Song;Eung Tae Kim;Seong Eun Ko;Sung Min Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.447-454
    • /
    • 2021
  • The authors report a successful thrombectomy using the AngioJet Rheolytic Thrombectomy System (AngioJet) and an embolic protection device in a patient with femorofemoral bypass graft occlusion. Lower extremity CT angiograms showed occlusion in the left-to-right femorofemoral bypass graft. A rheolytic thrombectomy using the AngioJet and balloon angioplasty restored blood flow to the right lower extremity, and distal embolization may be effectively prevented by placing an embolic protection device within the right superficial femoral artery during the procedure.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Massive Cerebral Microemboli after Protected Carotid Artery Angioplasty and Stenting Using a Distal Filter Embolic Protection Device for a Vulnerable Plaque with a Lipid Rich Necrotic Core and Intraplaque Hemorrhage: A Case Report (취약한 죽상경화반의 원위 필터형 색전예방장치를 이용한 내경동맥의 스텐트 시술 후 발생한 다량의 뇌 미세혈전: 증례 보고)

  • Hae-Jung Kim;Myung-Ho Rho
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.739-745
    • /
    • 2020
  • A major concern associated with carotid artery angioplasty and stenting (CAS) is a periprocedural distal cerebral embolization. To prevent distal embolization, embolic protection devices (EPDs) have been developed. However, the risk of cerebral embolism after protected CAS in patents with a vulnerable plaque is controversial and either a silent or a symptomatic stroke can occur despite the use of EPDs. Here, we report a case of a massive cerebral microemboli after a protected CAS using a distal filter EPD for a vulnerable plaque with a lipid rich necrotic core and intraplaque hemorrhage.

Flow arrest during carotid artery stenting with a distal embolic protection device: A single-center experience and clinical implications

  • Noah Hong;Jeong-Mee Park;Seung Bin Kim;Young-Je Son
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.163-173
    • /
    • 2024
  • Objective: We aimed to investigate the incidence of flow arrest during carotid artery stenting (CAS) with filter-type embolic protection device (EPD), identify any predisposing factors for those situations, and contemplate intraprocedural precautionary steps. Methods: CAS was performed in 128 patients with 132 arteries using filter-type EPD. The characteristics of treated patients and arteries were compared between groups with and without flow arrest. Results: The incidence of flow arrest during CAS with filter-type EPD was 17.4%. In flow arrest group, cases of vulnerable plaques (p=0.02) and symptomatic lesions (p=0.01) were significantly more common, and there were more cases of debris captured by EPD in a planar pattern (p<0.01). Vulnerable plaques were significantly more common in the procedures showing a planar pattern than in the cases with other patterns (p<0.01). Flow arrest group showed a significantly higher rate of ischemic complications (p<0.05), although there were no significant periprocedural neurological changes. The planar pattern of captured debris in filter-type EPD was the only significant risk factor for flow arrest (adjusted odds ratio 88.44, 95% confidence interval 15.21-514.45, p<0.05). Conclusions: Flow arrest during CAS with filter-type EPD is not uncommon and associated with increased ischemic complications. Symptomatic stenoses and vulnerable plaque are related to this event. The planar pattern of captured debris on the EPD was the only significant risk factor for the flow arrest. Clinicians must pay attention to the occurrence of flow arrest and react quickly when performing CAS.

Risk Factors for Developing Large Emboli Following Carotid Artery Stenting

  • Kwon, Sae Min;Cheong, Jin Hwan;Lee, Sang Kook;Park, Dong Woo;Kim, Jae Min;Kim, Choong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.155-160
    • /
    • 2013
  • Objective : The introduction and development of the embolic protecting device (EPD) has resulted in a decreased rate of stroke after carotid artery stenting (CAS). The authors performed a retrospective study to investigate the risk factors for developing large emboli after CAS which can lead to ischemic events. Methods : A total of 35 consecutive patients who underwent CAS between January 2009 and March 2012 were included in this study. Patients were divided into two groups including those with small emboli (group A; grade 1, 2) and those with large emboli (group B; grade 3, 4). The size and number of emboli were assigned one of four grades (1=no clots, 2=1 or 2 small clots, 3=more than 3 small clots, 4=large clots) by microscopic observation of the EPD after CAS. We compared demographic characteristics, medical history, and angiographic findings of each group. Results : Thirty-five patients underwent CAS, and technical success was achieved in all cases. Twenty-three patients were included in group A and 12 patients in group B. Our results demonstrated that advanced age [odds ratio (OR) 1.24; 95% confidence interval (CI) 1.01-1.52; p=0.044] and smoking (OR 42.06; CI 2.828-625.65, p=0.006) were independent risk factors for developing large emboli after CAS. Conclusion : In patients with carotid artery stenosis treated with CAS, advanced age and smoking increased the number and size of emboli. Although use of an EPD is controversial, it may be useful in CAS in patients with risk factors for large emboli in order to reduce the risk of ischemic events.