• Title/Summary/Keyword: Ellipsoid Height

Search Result 24, Processing Time 0.107 seconds

Accuracy Analysis of Ultra-high degree Earth Gravitational Model EGM2008 in South Korea (남한지역에서의 초고차항 중력장모델 EGM2008의 정확도 분석)

  • Huang, He;Yun, Hong Sic;Lee, Dong Ha;Jeong, Tae Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.161-166
    • /
    • 2009
  • High-resolution, high-precision ultra-high degree earth gravitational model are significant for the development of geodesy, geophysics, geodynamics and oceanography. In this research, we introduces the ultra-high earth gravitational model EGM2008 recently announced by U.S. NGA, reviews the issues and status of the ultra-high degree gravitational model development, and analyzes the accuracy of the gravitational model in Korea. First, EGM2008 is compared with the gravitational model EGM96 and Korea high-precision hybrid geoid model KGEOID08. In addition, the absolute accuracy is evaluated by ellipsoid height and orthometric height of a satellite geodetic reference point. Overall, the results show a similar accuracy between EGM2008 and KGEOID08. Thus, EGM2008 will be helpful for the future development of regional geoid and analysis of global gravity field.

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

On the Spawning Behavior and the Development of Korean Eleotrid Fish, Odontobutis obscurus (T. et S.) (한국산 동사리의 산란습성과 난발생 및 초기발육과정에 대하여)

  • Ki Chul Choi;Chang Deog Jin
    • The Korean Journal of Ecology
    • /
    • v.1 no.2
    • /
    • pp.44-48
    • /
    • 1977
  • The spawning behavior and developmental pattern of the Korean eleotrid fish (Odontobutis obscurus) was investigated in one of the tributary of Han River. The spawining of this species begins on April and continues up to August, whereas, the spawning. of same species were between the end of June and the middle of July in Kyushu, Japan. August The spawning places were the margin of river, its the bottom composed of sand and pebble (Table 5). The velocity of water in the spawning places was 0-40cm/sec, and the depth of waters was 10-40cm. The egg was spawned on underside of stone in the spawning places with one or two folds and ellipsoid in shape, 3.4mm in long diameter and 2.0mm in short diameter. The yolk is 1.2mm in diameter and yellow in color. For hatching of the egg, it takes one month in, $16^{circ}C~19^{\circ}C$ water, in Japan, whereas it takes only 14 days in $20^{circ}C~30^{\circ}C$ wate rin the study area. The growth rate of larva and juvenile fish were as follows: new hatched larva is 45mm in length; after 5 days it became 5.0 to 5.5mm in length and 1.2 to 1.5mm in height after 20 days. it became 11.0mm in length and 2.3mm in length. The mean size of the mature female is 110mm in total length and larger 10mm than that of the same fish found in Japan.

  • PDF

Sonographic renal length and volume of normal Thai children versus their Chinese and Western counterparts

  • Rongviriyapanich, Chantima;Sakunchit, Thanarat;Sudla, Chirawat;Mungkung, Supamas;Pongnapang, Napapong;Yeong, Chai Hong
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.12
    • /
    • pp.491-498
    • /
    • 2020
  • Background: Renal size is an important indicator in the diagnosis of renal diseases and urinary tract infections in children. Purpose: The purpose of this study is twofold. First, it aimed to measure the renal length and calculate the renal volume of normal Thai children using 2-dimensional ultrasonography (2D-US) and study their correlations with somatic parameters. Second, it aimed to compare the age-specific renal size of normal Thai children with the published data of their Western and Chinese counterparts. Methods: A total of 321 children (150 boys, 171 girls; age, 6-15 years) with a normal renal profile were prospectively recruited. All subjects underwent 2D-US by an experienced pediatric radiologist and the renal length, width, and depth were measured. Renal volume was calculated using the ellipsoid formula as recommended. The data were compared between the left and right kidneys, the sexes, and various somatic parameters. The age-specific renal lengths were compared using a nomogram derived from a Western cohort that is currently referred by many Thailand hospitals, while the renal volumes were compared with the published data of a Chinese cohort. Results: No statistically significant difference (P<0.05) was found between sexes or the right and left kidneys. The renal sizes had strong correlations with height, weight, body surface area, and age but not with body mass index. The renal length of the Thai children was moderately correlated (r=0.59) with that of the Western cohort, while the age-specific renal volume was significantly smaller (P<0.05) than that of the Chinese children. Conclusion: Therefore, we concluded that the age-specific renal length and volume obtained by 2D-US would vary between children in different regions and may not be suitably used as an international standard for diagnosis, although further studies may be needed to confirm our findings.