• 제목/요약/키워드: Eliminator

Search Result 47, Processing Time 0.113 seconds

Shape Optimization of a Thomson Coil Actuator for Fast Response Using Topology Modification

  • Li, Wei;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • The shape optimization of a Thomson coil actuator used in an arc eliminator is done for fast response by adopting topology modification method. The displacement of the plate in a fixed calculation time is taken as the objective function. The objective function and contribution factor are calculated by using an adaptive equivalent circuit method which has been proved accurate and efficient. Both shape optimization and performance analysis are accomplished based on the segmentation of plate. Through the refinement of the sensitive segments a precise optimal plate shape can be obtained. The effectiveness of the proposed method is proved by the comparison of results before and after the shape optimization.

Scrapped styrofoam crusher with sprayed air (or water) (공기(또는 물) 스프레이형 폐스치로폼 분쇄기)

  • Ko, K.Y.;Kim, B.S.;Lee, C.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.469-472
    • /
    • 2008
  • This research suggest one-body type scrapped styrofoam crusher with sprayed air (or water), which at present separately composed of dust eliminator, air supplier and crusher. Air (or water) that supplied from compressor injected to rotating twin roller through axis hole, and sprayed out of fine hole on the surface. The crusher that manufactured with sprayed air (or water) can make high-quality primary styrofoam removed pollution and dust. In case of mixed sprayed air and water, clean degree of crushed styrofoam was higher than single sprayed air. This could be contributed to reduce environmental pollution, cost and space in standpoint of recycling scrapped styrofoam.

  • PDF

Development of Defogger Equipped with a Roller Horsehair Brush

  • Ma, Chang-Jin;Kasahara, Mikio;Cao, Renqiu
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.226-231
    • /
    • 2016
  • In order to remove fog often causes various troubles in our daily lives, the novel defog blower equipped the roller brush made of recycled horse's mane hair was developed. This work presents the overview of new defog devices and the experimental data obtained at two different kinds of defogging experiments. In the model experiment carried out at the enclosed cleanroom ($W5.9m{\times}L5.1m{\times}H2.4m$) targeted a vinyl house, fog was dissipated in less than 30 seconds in case with wind entrainment and two minutes 45 seconds in case without wind entrainment after running of the newly designed defog blower. When the demisting blower was run in a duct, it has an excellent mist sweeping qualities as well as a great removal effect for the background particles (89.5% and 65.4% scavenging rates for fine and coarse particles, respectively). It can be therefore said that the mist eliminator presented in this paper is ideal for use in the sealing space like a vinyl house and the industrial sites where required to remove both harmful mist and particle.

Three-Phase 4-Wire Isolated Wind Energy Conversion System Employing VSC with a T-Connected Transformer for Neutral Current Compensation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.211-218
    • /
    • 2009
  • This paper presents a voltage and frequency controller (VFC) for a 4-wire stand-alone wind energy conversion system (WECS) employing an asynchronous generator. The proposed VF con-troller consists of a three leg IGBT (Insulated Gate Bipolar Junction Transistor) based voltage source converter and a battery at its DC bus. The neutral terminal for the consumer loads is created using a T-connected transformer, which consists of only two single phase transformers. The control algorithm of the VF controller is developed for the bidirectional flow capability of the active power and reactive power control by which it controls the WECS voltage and frequency under different dynamic conditions, such as varying consumer loads and varying wind speeds. The WECS is modeled and simulated in MATLAB using Simulink and PSB toolboxes. Extensive results are presented to demonstrate the capability of the VF controller as a harmonic eliminator, a load balancer, a neutral current compensator as well as a voltage and frequency controller.

Draw resonance in polymer processing: a short chronology and a new approach

  • Hyun, Jae-Chun
    • Korea-Australia Rheology Journal
    • /
    • v.11 no.4
    • /
    • pp.279-285
    • /
    • 1999
  • Draw resonance is both an important and interesting instability encountered in various extensional-deformation-dominated polymer processing operations. It is important because of its paramount relevance to the productivity and quality issue in the related industry: and it is interesting because of as yet unanswered questions as to what its cause and origin are in terms of physics involved. Specifically, a short chronological account of the draw resonance research is presented in this paper bringing several previous results together and focusing on the derivation of a new criterion for draw resonance based on the interaction of the traveling times of some kinematic waves propagating along the spinline from the die exit to the take-up position. The new explanation of draw resonance put forward here based on the physics of the system is seen to have wide implications on both theoretical and practical aspects of draw resonance instability. The importance of the role played by spinline tension in determining draw resonance is an example of the former whereas interpretation of the mechanism of the draw resonance eliminator is an example of the latter. Finally, an approximate yet a very fast and convenient method for determining draw resonance is also derived based on the above findings and found to agree well with the exact stability results.

  • PDF

Mechanical Design and Evaluation of Linear Tape Feeder for Chip Mounter (칩마운터의 직진 테이프 피더 설계 및 평가)

  • Lee Soo-Jin;Kang Sung-Min;Lee Chang-Hee;Kim Yong-Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.155-161
    • /
    • 2006
  • This paper introduces a new type of mechanical tape feeder for chip mounter. The mechanical feeder is composed of a pneumatic linear actuator and a linear feeding module with the application of a cam-slider. As semiconductor chips are getting smaller, PCB assembly makers require the feeder to position the chip with high accuracy. The linear feeding system improves the positioning accuracy of the chip by getting rid of the index error, which brings into existence on the sprocket rotating feeder. It also can make greatly reduce the dumping rate. The dumping error is caused by the impact occurred as the pawl to interrupt ratchet wheel rotation. The paper discusses its mechanism and mechanical performance. The positioning accuracy and the dynamic characteristic were measured for long time operation and analyzed. As a result, the feeder showed very good performance. However, the feeding system was dynamically unstable due to the cover film eliminator that is required to be modified

A Study of Removal $NH_{3}-N$ by Natural Zeolite in the Raw-Water (천연 Zeolite를 이용한 상수원수 중의 $NH_{3}-N$ 제거에 관한 연구)

  • 이지헌;김환범;안길원;박찬오;김익산;이종현;박혜영;박송인;이해훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.61-71
    • /
    • 1997
  • This study was conducted to examine the adsorption capacity of $NH_{3}-N$ by natural zeolite for the purpose of investigating the possibility for $NH_{3}-N$ eliminator of korea natural zeolite. The dominant clay minerals of zeolite was clinoptiloite. The amount of $NH_{3}-N$ adsorption by zeplite was not significantly affected by the particle size of zeolite and increased with increasing the ratio of zeolite to the volume of solution. Removal ratio of 100% of NH$_{3}$-N by non, 1st, 2nd regenerated cloumn was continued separately during 4.5, 18, 30hr and this amount was each 0.081, 0.324, 0.540g $NH_{3}-N/zero$.100g. The eluenting amount of K, Ca, Mg was increased on the zeolite cloumn according to that of Na decreased. The amount of 74% of $NH_{3}-N$ was desorved on the zeolite cloumn for regenerating treatment during 8hr. The perfect removal amount was $0.216gNH_{3}-N/zero$.100g on the zeolite cloumn with field sample.

  • PDF

An Interference Canceller-based Digital On-Channel Repeater to Improve Feedback Channel Estimation and RFP Performance (귀환 채널 추정 및 RFP 성능을 개선한 간섭 제거 기반의 동일 채널 중계기)

  • Choi, Soocheol;Cho, Kiryang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.2
    • /
    • pp.261-267
    • /
    • 2016
  • In this paper, Method for the phase distortion compensation timing offset and DC eliminator for the pilot component estimation and removal, transmitted and received signal correlation in the delay scheme DAB interference cancellation based on the same channel for using for estimating the feedback signal based on a between for removal for the timing offset compensation It proposes a repeater. This was applied to the ATSC system. The on-channel repeater of the proposed interference cancellation based on the interference removing capability is improved in interference signal is 20dB greater than the primary transmission signal environment via the return channel estimation and improve performance RFP. Accordingly, it was confirmed by simulation that good signal is sent out with the improvement of the ability of the repeater.

The Study on the experimental of a development of the filtering system for particle/gas phase contaminants (입자/가스상 오염물질 필터링 장치 개발에 관한 실험적 연구)

  • Kim, Tae-Hyung;Nam, Seung-Baeg;Ha, Jong-Pil;Moon, In-Ho;Cho, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.387-392
    • /
    • 2007
  • In this study performance evaluation of filtering system were made on the clean air supply system to show it's ability to eliminate the air contaminants. The evaluation was conducted inside the 3,200CMH scale wind tunnel and under the same environment that is effected by yellow dust and similar particle and gas phase contaminants in semi-conductor and FPDs industries. (1) The result of experimental for particle contaminants, the particle removing efficiency was 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05, electrified voltage : (+)5.8kV with electric charger and (-)3.5kV with eliminator. (2) The gas phase removing efficiency for $NH_3$ : 80%, $SO_X$ : 70% and $NO_X$ : 40% on condition that the air velocity is 2.5m/s, L/G ratio : 0.05.

  • PDF

Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator (관성 충돌 방식의 액적 분리장치의 수분제거효율 평가)

  • Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.