• Title/Summary/Keyword: Eliminating common mode voltage

Search Result 6, Processing Time 0.019 seconds

Novel Single-State PWM Technique for Common-Mode Voltage Elimination in Multilevel Inverters

  • Nguyen, Nho-Van;Quach, Hai-Thanh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.548-558
    • /
    • 2012
  • In this paper, a novel offset-based single-state pulse width modulation (PWM) method for achieving zero common-mode voltage (CMV) and reducing switching losses in multilevel inverters is presented. The specific active switching state of the zero common-mode (ZCM) voltage that approximates the reference voltage can be deduced from the switching state sequence of the reduced CMV phase disposition PWM (CMV PD PWM) method. From the reference leg voltages for the zero common-mode voltage, an N-to-2-level transformation defines a virtual two-level inverter and the corresponding nominal leg voltage references. The commutation process of the reduced CMV PD PWM method in a multilevel inverter and its outputs can be simply followed in a nominal switching time diagram for the virtual inverter. The characteristics of the reduced CMV PD PWM and the single-state PWM for zero common-mode voltage are analyzed in detail in this paper. The theoretical analysis of the proposed PWM method is verified by experimental results.

Analysis of Common Mode Voltages at Diode Rectifier/Z-Source Inverter System (다이오드 정류기/Z-소스 인버터 시스템의 공통모드 전압 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 2009
  • In this paper, when ac motors are driven by the diode rectifier/Z-source inverter system, the common-mode voltages of system are analyzed in details under both the shoot-through state and non-shoot-through state through equivalent circuits. Then a modified space vector modulation strategy is suggested for attenuating the negative common-mode voltage by eliminating the zero voltage vector, and also controlling the shoot-through time. Through the simulation studies with PSIM and experiments with 32-bit DSP, it is verified that the negative common-mode voltage can be reduced by more than 50%.

Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter (3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성)

  • Lee, Eun-Chul;Choi, Nam-Sup;Ahn, Kang-Soon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

A New Active Zero State PWM Algorithm for Reducing the Number of Switchings

  • Yun, Sang-Won;Baik, Jae-Hyuk;Kim, Dong-Sik;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.88-95
    • /
    • 2017
  • To reduce common-mode voltage (CMV), various reduced CMV pulse width modulation (RCMV-PWM) algorithms have been proposed, including active zero state PWM (AZSPWM) algorithms, remote state PWM (RSPWM) algorithms, and near state PWM (NSPWM) algorithms. Among these algorithms, AZSPWM algorithms can reduce CMV, but they increase the number of switchings compared to the conventional space vector PWM (CSVPWM). This paper presents a new AZSPWM algorithm for reductions in both the CMV and total number of switchings in BLAC motor drives. Since the proposed AZSPWM algorithm uses only active voltage vectors for motor control, it reduces CMV by 1/3 compared to CSVPWM. The proposed AZSPWM algorithm also reduces the total number of switchings compared to existing AZSPWM algorithms by eliminating the switchings required from one sector to the next. The performance of the proposed algorithm is verified by analyses, simulations, and experimental results.

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

A Single-Bit 2nd-Order CIFF Delta-Sigma Modulator for Precision Measurement of Battery Current (배터리 전류의 정밀 측정을 위한 단일 비트 2차 CIFF 구조 델타 시그마 모듈레이터)

  • Bae, Gi-Gyeong;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.184-196
    • /
    • 2020
  • In this paper, a single-bit 2nd-order delta-sigma modulator with the architecture of cascaded-of-integrator feedforward (CIFF) is proposed for precision measurement of current flowing through a secondary cell battery in a battery management system (BMS). The proposed modulator implements two switched capacitor integrators and a single-bit comparator with peripheral circuits such as a non-overlapping clock generator and a bias circuit. The proposed structure is designed to be applied to low-side current sensing method with low common mode input voltage. Using the low-side current measurement method has the advantage of reducing the burden on the circuit design. In addition, the ±30mV input voltage is resolved by the ADC with 15-bit resolution, eliminating the need for an additional programmable gain amplifier (PGA). The proposed a single-bit 2nd-order delta-sigma modulator has been implemented in a 350-nm CMOS process. It achieves 95.46-dB signal-to-noise-and-distortion ratio (SNDR), 96.01-dB spurious-free dynamic range (SFDR), and 15.56-bit effective-number-of-bits (ENOB) with an oversampling ratio (OSR) of 400 for 5-kHz bandwidth. The area and power consumption of the delta-sigma modulator are 670×490 ㎛2 and 414 ㎼, respectively.