• Title/Summary/Keyword: Elevator lobby

Search Result 13, Processing Time 0.015 seconds

A Study on the Evaluation for Elderly Housing Environment - Countent Analysis of Elderly Housing Environment Literature Issued after 2000 - (노인주거환경 평가 틀에 관한 연구 - 2000년 이후의 노인주거환경관련 논문에 대한 내용분석을 중심으로 -)

  • Shin, Hwa-Kyoung;Lee, Joon-Min
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.151-159
    • /
    • 2010
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The study are as follows; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design'environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design' environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

A Brief Study on Smoke Suppression Effects by Sprinkler Spray System (스프링클러설비에 의한 연기제어효과 고찰)

  • Cha, Jong-Ho;Yoon, Myung-O;Choi, Chun-Bae;Lee, Sun-Kyung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.560-565
    • /
    • 2006
  • Sprinkler system is the most effective fire suppression with high confidence among active fire extinguishing systems. According to the installation of the related system on buildings, more separation area of fire protection can be considered to the fire protection design, and also lower differential pressure (12.5 Pascal) is permitted on lobby of fire escape stairs and emergency elevator (25 Pascal shall be considered for none sprinkler system) with economic factor. More details will be handled on the related studies.

  • PDF

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.