• Title/Summary/Keyword: Elevator Noise

Search Result 53, Processing Time 0.014 seconds

Analysis of frequency characteristics and evaluation methods of elevator noise (승강기 소음의 주파수 특성 분석 및 평가 방법 고찰)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.607-614
    • /
    • 2021
  • Research on elevator noise has mainly focused on the cause of its occurrence and measures to reduce it. There is still insufficient research on how to accurately measure and evaluate elevator noise. There is a measurement method established as an international standard for the measurement method, but it is also difficult to apply to high-rise apartments, and there are many cases that do not closely reflect the characteristics of elevator noise. In order to solve this problem, a study was conducted to improve the elevator noise measurement method in the current standard. In this study, the characteristics of elevator noise were closely identified. Through frequency analysis of the elevator noise and other equipment, it was verified that the elevator noise is noise with different characteristics from other equipment. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. The correlation between bang machine and rubber ball was found to be very high at 0.9 level. As a result, it was verified that the mid-low frequency band of the elevator noise is the main structural transmission noise and cannot be evaluated together with other equipment.

Evaluation of Elevator Noise level of Apartment Houses through Vibration Measurement (진동측정을 통한 공동주택 엘리베이터 소음 레벨 평가)

  • Kang, Min-Woo;Song, Min-Jeong;Oh, Yang-Ki
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.641-654
    • /
    • 2018
  • Elevator noise in apartment houses is one of the factors which prevent the residents from quiet and comfortable life. The elevator noise measurement method [KS F ISO 16032] is introduced from the matching ISO standard, however, it has problems in the application to the actual measurement. To visualize the problems, measurements in an apartment house are conducted, which has been suffering from the elevator noise for a long time. The measurement itself is extremely difficult due to the low sound pressure level of elevator, which is lower than 35 dB (A), and the even higher background noise level. However the vibration levels measured at the same time are relatively less disturbing As a result of vibration measurement, it was found that the vibration is clearly measured on the wall, and presents a high correlation coefficient of over 0.8 with the noise levels measured This shows that the vibration level measured on the elevator walls may be rather reliable numbers than the elevator noise levels in the actual noisy condition of elevator halls and the vicinity.

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.

The Countermeasure which reduces the Noise and Vibration of the building Elevator (건축물(建築物) Elevator의 소음진동(騷音振動) 저감(低減) 방안(方案))

  • Jeon, Euy-Sik;Cho, Byoung-Hoo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.5 no.2
    • /
    • pp.36-42
    • /
    • 2005
  • The interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the vibration which occurs from the elevator cage of the building is possibility of damage to the users of the building continuously. So, the purpose of this study is a placeThe interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the noise and vibration which occurs from the elevator of the building is possibility of damage to the users of the building continuously. So, the objective of this research is to investigate the noise and vibration of the elevator and propose the method which reduces of it gained thorough this study.

  • PDF

A study on the characteristics and actual conditions of operation noise and vibration of rope elevators in high-rise apartments (고층아파트 로프식 승강기의 운행 소음 및 진동 특성과 실태에 관한 연구)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.84-91
    • /
    • 2021
  • An Elevator is a very important equipment in high-rise apartments. The noise generated by an elevator is causing inconvenience to residents. However, there are no laws and regulations on elevator noise, and moreover it is not clear how to measure and evaluate elevator noise. For these problems, the first priority should be given to grasping the characteristics of noise and vibration generated during elevator operation. In this study, noise and vibration generated when operating a rope-type elevator in a high-rise apartment are divided according to the number of floors and the type of room, and the noise and vibration are simultaneously measured to understand the characteristics of noise and vibration. The correlation coefficient according to the experimental conditions was determined. As a result, it was found that elevator noise was mainly composed of components in the 125 Hz to 500 Hz band, and the correlation with vibration in the 125 Hz to 500 Hz band was also significant. For the top layer, it was confirmed that the correlation coefficient was very high at 0.8 level.

Research on the Elevator-operating Noise and Vibration in Apartment Buildings (공동주택 승강기 운행소음ㆍ진동 실태 및 저감설계)

  • 김명준;김하근;김흥식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.488-493
    • /
    • 2001
  • In accordance with the tendance to construct high-rise apartment buildings, the transporting elevators tend to speed up to 90-105m/min and to drive more frequently. So, the problem of noise produced by the elevator operation has been treated as an important subject. In this research, the actual conditions of noise and vibration which generated and transmitted by the elevator operation in apartment buildings were measured and analysed. And the several noise and vibration control design which helps reduce noise were examined.

  • PDF

A Study on the Characteristics of Vibration and Noise to be occurred to operating Elevator in Apartment (공동주택 엘리베이터 운행시 발생하는 진동ㆍ소음 특성에 관한 연구)

  • 배동명;신창혁;김도균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.938-943
    • /
    • 2003
  • In accordance with the tendance to construct high-rise apartment buildings, the elevators tend to high speed up and to the drive more frequently. So, the problem of vibration and noise produced by the operating elevator has been treated as an important subject all the more. In this research, the actual levels of vibration and noise which generated and transmitted by the elevator operation in apartment buildings were measured and these characteristics were analysed to examine the countermeasures to be able to reduce the these vibration and noise level, and to design the several vibration and noise control.

  • PDF

Experiments on Rope Vibrations using a Small-Scale Elevator Simulator (엘리베이터 시뮬레이터를 이용한 로프 진동 실험)

  • Yang, Dong-ho;Kwak, Moon K.;Kim, Ki-young;Baek, Jong-dae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.252-255
    • /
    • 2014
  • The elevator rope is easy to oscillate and continue vibrating because the rope structure is flexible and inner damping is small. The vibration of elevator rope is caused by the building vibration excited by external disturbances such as winds and earthquake. This paper is concerned with the experimental verification of the elevator rope vibrations using a small-scale simulator. The elevator rope vibration coupled with the building vibration was modelled using the energy method in the previous study. In this study, the natural frequencies of the elevator rope were computed using the theoretical model and compared to experimental results. Also, the time-responses of the rope vibration during the cage motion were measured by laser sensors and compared to the theoretical predictions. Experimental results are in good agreement with theoretical predictions.

  • PDF

Active Control Experiments on High-speed Elevator Vibrations (고속 엘리베이터 능동진동제어 실험)

  • Kim, Ki-Young;Kwak, Moon-K.;Baek, Kwang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.325-332
    • /
    • 2011
  • This paper is concerned with the active control experiments on elevator vibrations by means of the active roller guide. To this end, a roller guide was designed using a voice-coil actuator and linear guide. A simple proportional control algorithm combined with the band-pass filter was implemented using the DSP. Based on the initial experiments, a new control system which can handle lateral and front-back vibrations of elevator was built and tested using the elevator test tower. The experimental results show that the elevator vibrations are reduced by the active control technique.

Dynamic Modeling and Active Controller Design for Elevator Lateral Vibrations (엘리베이터 횡진동 동적 모델링 및 능동진동제어기 설계)

  • Kwak, Moon-K.;Kim, Ki-Young;Baek, Kwang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.154-161
    • /
    • 2011
  • This paper is concerned with the modeling and active controller design for elevator lateral vibrations. To this end, a dynamic model for the lateral vibration of the elevator consisting of a supporting frame, cage and active roller guides was derived using the energy method. Free vibration analysis was then carried out based on the equations of motion. Active vibration controller was designed based on the PID control algorithm and applied to the numerical model. Rail irregularity were considered as external disturbance in the numerical simulations. The numerical results show that the active vibration control of elevator is possible.