• Title/Summary/Keyword: Elevator Control

Search Result 218, Processing Time 0.022 seconds

Fuzzy Control of Elevator Speed Pattern (엘리베이터 속도 패턴의 퍼지 제어)

  • Ahn, Tae-Chon;Kang, Jin-Hyun;Kang, Doo-Young;Yoon, Yang-Woong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.7
    • /
    • pp.857-864
    • /
    • 2004
  • In this paper, a new speed pattern generation method is proposed to offer various speed patterns for the traffic changers, with the comfortable driving and the rapid transportation speed that are two important factors to determine elevator speed pattern. To reduce the speed shift impulse, acceleration and deceleration times are appropriately adjusted to the elevator system when start and stop. In order to improve transportation capability, the jerk is also adjusted to the traffic change. Using fuzzy inference system with 2 input variables and 1 output, the elevator system controls precisely, with the proposed speed pattern.

An Experimental Study on the Estimation for the Flow Coefficient of Elevator Hoistway (엘리베이터 승강로의 유량계수 산정에 관한 실험 연구)

  • Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the flow coefficient of hoistway when elevator is moving. The results of this study can be used for the study of elevator piston effect as basic data. Experiments were performed in 5 different hoistways at 3-story and 2-story buildings. According to the result of flow coefficient experiments, average flow coefficient is 0.954. Considering the $4{\sigma}$ to guarantee 99.99 % reliance, it is 0.86. This result is 3.6 % bigger than 0.83 that Klote and Tamura suggested. It represents that the maximum critical pressure is decreased about 7 % on the same condition of elevator and elevator shaft. When the smoke control performance of high-rise building is evaluated, the result is significant economically by applying a more realistic and less value of elevator piston effect.

Elevator Algorithm Design Using Time Table Data (시간표 데이터를 이용한 엘리베이터 알고리즘 설계)

  • Park, Jun-hyuk;Kyoung, Min-jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.122-124
    • /
    • 2022
  • Handling Passenger Traffic is the main challenge for designing an elevator group-control algorithm. Advanced control systems such as Hyundai's Destination Selection System(DSS) lets passengers select the destination by pressing on a selecting screen, and the systems have shown great efficiency. However, the algorithm cannot be applied to the general elevator control system due to the expensive cost of the technology. Often many elevator systems use Nearest Car(NC) algorithms based on the SCAN algorithm, which results in time efficiency problems. In this paper, we designed an elevator group-control algorithm for specific buildings that have approximate timetable data for most of the passengers in the building. In that way, it is possible to predict the destination and the location of passenger calls. The algorithm consists of two parts; the waiting function and the assignment function. They evaluate elevators' actions with respect to the calls and the overall situation. 10 different timetables are created in reference to a real timetable following midday traffic and interfloor traffic. The specific coefficients in the function are set by going through the genetic algorithm process that represents the best algorithm. As result, the average waiting time has shortened by a noticeable amount and the efficiency was close to the known DSS result. Finally, we analyzed the algorithm by evaluating the meaning of each coefficient result from the genetic algorithm.

  • PDF

Development of the intelligent building control system simulator for the performance analysis (인텔리젼트 빌딩 제어 시스템의 성능해석을 위한 시뮬레이터 개발)

  • 배중원;임동진;송규동
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.624-627
    • /
    • 1996
  • To provide pleasant building environment and the ease of maintenance and facility management, many new office buildings are being built as intelligent buildings. Building control systems which are employed in intelligent buildings require advanced types of controllers and varieties of control schemes. Designing and installation of these types of advanced building control systems take a lot of effort and also they are costly. In order to design these systems, it is necessary for the designers to have means to analyze and estimate the performance of control systems. The simulator which is presented in this paper is composed of three parts, HVAC simulation module, elevator simulation module, and evacuation modeling module for the outbreak of fire or similar disasters. In this paper, the functions and modelling method for each module are explained and simulation results are presented.

  • PDF

A Design for Elevator Group Controller of Building Using Adaptive Dual Fuzzy Algorithm

  • Kim, Hun-Mo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1664-1675
    • /
    • 2001
  • In this paper, the development of a new group controller for high-speed elevators is described utilizing the approach of adaptive dual fuzzy logic. Some goals of the control are to minimize the waiting time, mean-waiting time and long-waiting time in a building. When a new hall call is generated, all adaptive dual fuzzy controller evaluates the traffic patterns and changes the membership function of a fuzzy rule base appropriately. A control algorithm is essential to control the cooperation of multiple elevators in a group and the most critical control function in the group controller is an effective and proper hall call assignment of the elevators. The group elevator system utilizing adaptive dual fuzzy control clearly performs more effectively than previous group controllers.

  • PDF

Hybrid Sliding-Mode Controller for the Speed Control of a Hydraulic Inverter-Fed Elevator (유압식 인버터 엘리베이터의 속도제어를 위한 하이브리드 슬라이딩모드제어기)

  • Han, Gueon-Sang;Park, Jae-Sam;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.6
    • /
    • pp.37-47
    • /
    • 2001
  • Due to the friction characteristics of pump, cylinder packing and passenger car, in the elevator actuated with hydraulic inverter-fed systems, there exist dead zones, which cannot be controlled by a PID controller. To overcome the drawbacks, in this paper, we propose a new hybrid control scheme, which switches the modes between a sliding mode controller and a PID controller. The proposed hybrid control scheme achieves an improved control performance by using both controllers. We first propose a design method of sliding mode controller for a hydraulic elevator system controlled by inverters, then fellowed by a design method of a hybrid sliding mode control scheme is proposed. The effectiveness of the proposed control scheme are shown by simulation results, which the proposed hybrid control method yields better control performance then the PID controlled scheme, not only in the zero-crossing speed region but also in the overall control region including steady-state region.

  • PDF

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

Efficient Scheduling of Sensor-based Elevator Systems in Smart Buildings (스마트 빌딩을 위한 센서 기반의 효율적인 엘리베이터 스케줄링)

  • Bahn, Hyokyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.367-372
    • /
    • 2016
  • In a modern smart building, sensors can detect various physical conditions, such as temperature, humidity, sound, motion, and light, which can be used in medical services and security, and for energy savings. This paper presents an efficient elevator scheduling system that utilizes smart sensor technologies with radio-frequency identification, video, and floor sensors to detect the arrival of elevator users in advance. The detected information is then delivered to the elevator scheduling system via building networks. By using this information, the proposed system makes a reservation call for efficient control of the elevator's direction and time. Experiments under a spectrum of traffic conditions show that the proposed system performs better than a legacy system with respect to average wait time, maximum wait time, and energy consumption.

A Study on the Development of an Elevator Rope Tension Automatic Equalizer (엘리베이터 로프장력 자동조절기 개발에 관한 연구)

  • Kim, Dong-Bok;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.60-66
    • /
    • 2020
  • In this paper, we describe a rope tension automatic equalizer that automatically adjusts several rope tensions connecting the elevator car and the counterweight. The automatic rope tension equalizer is composed of a body, ram, and rope shaft. The body includes a cylinder hole, in which a ram is assembled. A rope shaft is assembled in a hole in the ram. Moreover, the rope is fixed to the rope shaft, with a hole through which fluid can pass between each cylinder hole and the hole of the body. The central concept is that the force of each rope is evenly distributed by the hydraulic pressure between the ram and the body cylinder when the rope is pulled. The thickness of the jaw connecting the small and large diameters of the body of the rope tension automatic equalizer was 15 mm based on structural analysis. The results of the representative experiment to install the produced rope tension equalizer on the elevator revealed it was possible to reduce the rope tension deviation by more than 71 kg.