• 제목/요약/키워드: Elekta

검색결과 27건 처리시간 0.026초

Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.

이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가 (Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC))

  • 김애란;서재혁;신헌주;박형욱;이기웅;이재춘;김신욱;김지나;박혜리;이희관;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.223-228
    • /
    • 2015
  • 이중으로 집중된 미세 다엽콜리메이터(Double-focused micro Multileaf Collimator: ${\mu}MLC$)는 보통의 다엽콜리메이터(Multileaf Collimator: MLC)에 비하여 조사면 가장자리 부분의 선량을 급격하게 줄여준다. 이러한 특성 때문에, 미세 다엽 콜리메이터는 정위적 방사선 수술과 치료(Stereotactic Radio-Surgery/RadioTtherapy, SRS/SRT)에 사용되어 왔다. 우리는 Elekta Synergy 선형가속기에 이중으로 집중된 동적 미세 다엽콜리메이터(Double-focused Dynamic micro-Multileaf Collimator: DMLC)를 부착하여 선량학적 특성을 평가하였다. 본 연구에서는, 필름(GafChromic EBT2 film), EDGE 다이오드 검출기, 3차원 물 팬텀을 이용하였다. 깊이선량백분율(Percent Depth Dose, PDD), 엽 투과도(leaf leakage), 반그림자(Penumbra)를 측정하였고, 모든 데이터들은 6MV 광자선으로 측정하였다. 그 결과, DMLC가 1% 이내의 투과도를 갖는것을 확인할 수 있었다. DMLC는 이중으로 집중 되는 구조를 가졌기 때문에 반 그림자가 조사야 크기에 대하여 독립적인 것을 확인하였다. 본 연구에서는 DMLC의 선량학적 특성을 바탕으로, Elekta Synergy에 부착된 DMLC의 적용 가능성을 증명하였다.

Neutron dosimetry with a pair of TLDs for the Elekta Precise medical linac and the evaluation of optimum moderator thickness for the conversion of fast to thermal neutrons

  • Marziyeh Behmadi;Sara Mohammadi;Mohammad Ehsan Ravari;Aghil Mohammadi;Mahdy Ebrahimi Loushab;Mohammad Taghi Bahreyni Toossi;Mitra Ghergherehchi
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.753-761
    • /
    • 2024
  • Introduction: In this study, TLD 600 and TLD 700 pairs were used to measure the neutron dose of Elekta Precise medical linac. To this end, the optimum moderate thickness for the conversion of fast to thermal neutrons were evaluated. Materials and methods: 241Am-Be and 252Cf sources were simulated to calculate the optimum thicknesses of the moderator for the conversion of maximum fast neutrons (FN) into thermal neutrons (TN). Pair TLDs were used to measure F&TN doses for three different field sizes at four depths of the medical linac. Results: The maximum thickness of the moderator was optimized at 6 cm. The measurement results demonstrated that the TN dose increased with the expansion of field size and depth. The FN dose, which was converted TN, exhibits behaviors comparable to the TN due to its nature. Conclusion: This study presents the optimum thickness for the moderator to convert FN into TN and measure F&TN using TLDs.

방사선치료의 다양한 EPID 영상 질평가 (Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;김정민;정회원;권경태;조정희;이제희;정재용;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.451-461
    • /
    • 2015
  • MV방사선 치료는 둘러싸여 있는 정상조직의 피폭선량을 최소화 하면서, target volume 내에 정확하게 선량을 전달하는데 있어 중요한 요인이다. 본 연구에서는 방사선 치료의 높은 정확성을 유지하기 위하여 megavoltage X-ray imaging (MVI)에서 edge block 을 사용한 digital radiography (DR) system 검출기의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하고자 한다. 우리는 텅스텐으로 구성된 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$의 edge block을 사용하였으며, 다음과 같은 setting들로 pre-sampling modulation transfer function (MTF)를 계산하였다: 6-megavolt (MV) energy를 사용하고, 다양한 Radiotherapy장비인 TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta), ClinacR iX (Varian) 를 사용하였다. MTF결과에서 Varian TrueBeamTM flattening filter free가 MTF의 50% ($mm^{-1}$)에서 0.46, 10% ($mm^{-1}$) 에서 1.40로 가장 highest value를 보였다. Noise 분포는 Elekta iViewGT가 가장 낮은 분포를 보였다. DQE에서는 E lekt a iViewGT가 peak DQE에서 0.0026 그리고 $1mm^{-1}$ DQE 에서 0.00014로 가장 높았다. 본 연구는 Edge method를 이용하여 MTF와 DQE산출을 재현하였으며, 현재 임상에서 사용되는 DR 시스템 측정의 높은 정확성을 유지할 수 있었으며 이러한 연구는 전통적인 QA 영상화뿐만 아니라 검출기 개발 연구에 있어서 정량적인 MTF, NPS, DQE 측정에 더욱 더 효율적으로 사용될 수 있다는 것을 알 수 있다.

An Empirical Approach to Dosimetric Effect of Carbon Fiber Couch for Flattening Filter Free Beam of Elekta LINAC

  • Ahn, Sohyun;Park, Kwangwoo;Kim, Jinsung;Lee, Ho;Yoon, Jeongmin;Lee, Eungman;Park, Sohyun;Park, Jeongeun;Kim, Juhye;Keum, Ki Chang
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.220-223
    • /
    • 2016
  • Generally, it is recommended that the dosimetric effect of carbon fiber couch should be considered especially for an intensity-modulated therapy with a large portion of monitor units from posterior angles. Even a flattening filter free (FFF) beam has been used for stereotactic body radiation therapy (SBRT), the effect of carbon fiber couch for FFF beam is not well known. This work is an effort to evaluate the dosimetric effect of carbon fiber couch for flattened and FFF beam of Elekta linac empirically. The absorbed doses were measured with Farmer type chamber and water-equivalent phantoms with and without couch. And differences of the absorbed doses between with and without couch defined as "couch effect". By comparing calculated dose in treatment planning system (TPS) with measured dose, the optimal density of couch was evaluated. Finally, differences on patient's skin dose and target dose by couch were evaluated in TPS. As a result, the couch effect for 6 and 10 MV flattened beam were -2.71% and -2.32%, respectively. These values were agreed with provided data by vendor within 0.5%. The couch effect for 6 and 10 MV FFF beam were -3.75% and -2.80%, respectively. The patient's skin dose was increased as 18.6% and target dose was decreased as 0.87%, respectively. It was realized that the couch effect of FFF beam was more severe than that of flattened beam. Patient's skin dose and target dose were changed by the couch effect.

방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교 (Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 김기원;최관우;정회원;장서구;권경태;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.171-176
    • /
    • 2016
  • 영상화 품질향상은 방사선 치료영역과 진단영역의 영상화 검사와 같이 quality assurance (QA) 장비들의 특성평가에 매우 중요한 요소이다. 본 연구의 목적은 치료장비의 megavoltage X-ray 에너지를 사용하여 측정방법에 있어서 NPS에 대한 수평, 수직적인 방법에 대한 측정결과를 비교 평가하는 것이다. 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission (IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 사용한 전자포털 영상장치(electronic portal imaging device, EPID)는 Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 데이터들로부터 각각의 주파수 값에 대응하는 노이즈 값들의 평균에 대해서, 각각의 주파수 별로 대응해서 표현하였으며, 수평 수직되어있는 주파수별 평균값의 노이즈값을 합산해서 정량적으로 장비마다 비교 평가하였다. 결과값은 Elekta iView에서 4가지 방법론에 의한 가로방향에서의 horizontal측정된 NPS값과 vertical 세로방향에서의 측정치는 비슷한 경향성에 따라서 horizontal과 vertical값은 3~5%정도의 차이가 있었으며, Siemens BEAMVIEW$^{PLUS}$, Varian Clinac$^R$ iX aS1000에서 horizontal측정된 NPS값과 vertical 측정된 NPS값은 편차의 차이가 전체값의 평균으로 했을 시 horizontal과 vertical값은 15%정도의 차이가 나타남을 보였다. 본 연구에서는 수평 수직되어있는 주파수별 평균값의 노이즈값을 합산해서 정량적으로 장비마다 비교 평가하였으며, 정량적인 평가방안을 제시하였다는 점을 둘 수 있다.

방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교 (Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;정회원;권경태;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.99-105
    • /
    • 2016
  • 잡음전력스펙트럼 (noise power spectrum, NPS)는 noise 진폭의 측정과 균일한 방사선 영역으로부터 획득된 영상의 품질에 가장 일반적인 방법 중 하나이다. 이 연구의 목적은 megavoltage X-ray 에너지를 사용하여 다른 잡음 전력스펙트럼 방법론들을 비교하는 것이다. 진단 영역에서의 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission(IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 우리가 사용한 전자포털영상장치(electronic portal imaging device, EPID)는 Varian TrueBeam$^{TM}$, Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 잡음전력스펙트럼의 관심영역을 측정하기 위해, 우리는 겹침 (overlapping), 비겹침 (non-overlapping), 평탄도 (flatness), 반음영 (penumbra) 4가지 인자를 사용하였다. 결과적으로는 Siemens BEAMVIEW$^{PLUS}$, Varian TrueBeam$^{TM}$ flattening filter, Varian Clinac$^R$ iX aS1000, Varian TrueBeam$^{TM}$ flattening filter free에서의 잡음 (noise) 분포는 기존의 첫번째, 두번째, 세번째 실험방법보다는 Elekta iViewGT보다 현격하게 높은 noise 분포가 나타남을 알 수 있다. 이번 연구는 다양한 인자들이 잡음전력스펙트럼의 megavoltage imaging (MVI)영상에서 MVI영역에서 잡음전력 스펙트럼의 기준의 방법론으로 사용되어질 수 있다는 것을 보여주었다.

뇌자도를 이용한 어휘적 중의성의 처리와 관련된 대뇌 신경활동 분석 (Magnetoencephalographic Study on the cerebral neural activities related to the processing of lexically ambiguous words)

  • 유기순;김준식;정천기;남기춘
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2007년도 한국음성과학회 공동학술대회 발표논문집
    • /
    • pp.59-63
    • /
    • 2007
  • Neuromagnetic fields were recorded from normal 10 subjects to investigate the time course of cerebral neural activation during the resolution of lexical ambiguity. All recordings were made using a whole-head 306-channel MEG (Elekta Neuromag TM Inc., $Vectorview^{TM}$). The observed activity was described by sLORETA (standardized low resolution brain electromagnetic tomography) techniques implemented in CURRY software (Neuroscan). In the results, bilaterally occipito-temporal lobe was activated at 170ms. At 250ms was associated with bilateral temporal lobe during ambiguous condition, whereas in left parietal, temporal lobe on unambiguous condition. The left frontal lobe, temporal lobe were activated at 350ms for all condition. At approximately 430ms, was activated in right frontal, temporal lobe on the resolving ambiguous condition, in left parietal lobe, right temporal lobe on the preserving ambiguous condition. In conclusion, the cerebral activations related to the resolving lexical ambiguity were right frontal lobe and the areas of mountainous ambiguity were left parietal lobe.

  • PDF

민들레 추출물의 방사선 방호효과 (Radioprotective Effects of Dandelion(Taraxacum officinale))

  • 최준혁;지태정;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제13권1호
    • /
    • pp.287-293
    • /
    • 2013
  • 민들레는 한방에서 산화방지, 위장 점막 보호 및 담즙 등에 탁월한 효과가 있다고 알려져 있다. 민들레 잎과 뿌리에서 추출한 물질을 SD Rat에 투여한 후 10Gy 방사선 조사 후에 생존율, 혈액변화, 소장조직변화 및 간 조직 변화를 관찰하였다. 관찰결과 민들레 추출물을 투여한 실험군에서 생존율이 4배 이상 높았으며 백혈구, 혈소판 등의 혈액변화에서도 뚜렷한 차이가 보였다. 또한 소장 조직 관찰결과 소장점막세포 소멸 억제 및 소장 점막근판 조직의 염증과 공포가 감소되었다. 따라서 민들레 추출물이 방사선 조사에 따른 혈액구성세포와 소장 조직 손상에 대한 방사선 방호효과를 확인하였다.

A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor

  • Kim, Tae Hoon;Lee, Sangmin;Kim, Dong Geon;Jeong, Jae Young;Yang, Hye Jeong;Schaarschmidt, Thomas;Choi, Sang Hyoun;Cho, Gyu-Seok;Kim, Yong Kyun;Chung, Hyun-Tai
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3018-3025
    • /
    • 2021
  • The authors developed a volumetric dosimetry detector system using in-house 3D-printable plastic scintillator resins. Three tumor model scintillators (TMSs) were developed using magnetic resonance images of a tumor. The detector system consisted of a TMS, an optical fiber, a photomultiplier tube, and an electrometer. The background signal, including the Cherenkov lights generated in the optical fiber, was subtracted from the output signal. The system showed 2.1% instability when the TMS was reassembled. The system efficiencies in collecting lights for a given absorbed energy were determined by calibration at a secondary standard dosimetry laboratory (kSSDL) or by calibration using Monte Carlo simulations (ksim). The TMSs were irradiated in a Gamma Knife® IconTM (Elekta AB, Stockholm, Sweden) following a treatment plan. The energies absorbed to the TMSs were measured and compared with a calculated value. While the measured energy determined with kSSDL was (5.84 ± 3.56) % lower than the calculated value, the energy with ksim was (2.00 ± 0.76) % higher. Although the TMS detector system worked reasonably well in measuring the absorbed energy to a tumor, further improvements in the calibration procedure and system stability are needed for the system to be accepted as a quality assurance tool.