CO2 냉매용 전자팽창밸브의 해석 및 평가 (Analysis and Performance Test of an Electronic Expansion Valve for CO2)

  • 김욱중;윤석호;홍용주;김정엽;강신일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1491-1496
    • /
    • 2009
  • Fluid flow and structural analyses of an electronic expansion valve (EEV) using CO2 as a working refrigerant are carried out to estimate the mass flow rate and maximum stress. An engineering sample EEV that the orifice diameter is 1.8 mm was fabricated. The mass flow rates were measured at various EEV inlet temperatures and pressures for several EEV openings using experimental heat pump system. The sample EEV has over 35 MPa burst pressure and the maximum mass flow rate of CO2 through the EEV increased to 100 g/s at full opening condition.

  • PDF

복수 실내기를 가지는 에어컨의 정상상태 성능해석 (Steady-State Performance Analysis of Air Conditioner with Multi-Indoor Units)

  • 허현;이진욱;정의국;김병순
    • 대한기계학회논문집B
    • /
    • 제40권11호
    • /
    • pp.705-715
    • /
    • 2016
  • 본 연구의 목적은 에어컨 사이클 성능해석에 있다. 응축기, 증발기, 팽창밸브 및 압축기는 냉동사이클을 구성하는 핵심요소이다. 사이클의 개별적인 구성요소들에 대한 해석 기법들을 합리적으로 통합하여 다양한 운전조건에서 에어컨 시스템 성능예측이 가능하도록 하였다. 응축기 압력은 압축기 질량유량과 팽창밸브 유량이 일치하도록 반복계산에 의해 획득되며, 증발기 압력은 목표 흡입과열도가 획득되도록 압축기 흡입엔탈피를 반복계산에 의해 획득되었다. 더 나아가서 복수 실내기를 장착한 에어컨 시스템의 성능이 예측될 수 있도록 알고리듬들이 마련되었으며, 이들 모델들에 대한 해석결과를 제시하였다. 소프트웨어의 정확성은 실험결과에 의해 증명 되었다. 특히, 8.3 kW급 모델의 실험결과와 비교함으로써, 소프트웨어의 정확성이 다양하게 검정되었다. 해석결과로써, 정확성은 대체적으로 10% 이내에 있는 것으로 확인되어 우수한 신뢰성이 확보되었다.

HVAC 시스템에 대한 PSO 알고리즘을 이용한 최적화된 Multi-Fuzzy 제어기 설계 (Design of Optimized Multi-Fuzzy Controller by Means of Particle Swarm Optimization Algorithm for HVAC System)

  • 정승현;최정내;오성권;최한종;류병진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.277-278
    • /
    • 2007
  • 본 논문은 HVAC(heating, ventilating, and air conditioning) 시스템에 대해 Particle Swarm Optimization(PSO) 알고리즘을 이용하여 최적화된 Multi-Fuzzy 제어기 설계를 제안한다. HVAC 시스템의 효율과 안정도에 결정적인 영향을 미치는 과열도와 저압(증발기의 압력)을 제어하기 위해, 3대의 Expansion Valve 와 1대의 Compressor 에서 동시에 제어하는 Multi-Fuzzy 제어기를 설계한다. 그리고 최적화 알고리즘 중 하나인 사회적인 행동양식을 기반한 PSO 알고리즘을 이용하여 설계된 Multi-Fuzzy 제어기를 최적화한다. 시뮬레이션의 결과 비교를 통해, 대표적인 최적화 알고리즘인 유전자 알고리즘을 사용한 최적화된 제어기와 제안한 PSO 알고리즘을 이용한 최적화된 제어기의 성능을 평가한다.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

하천수열원을 이용한 2단압축 열펌프의 난방성능 시뮬레이션 (Simulation on the Heating Performance of a 2-Stage Compression Heat Pump System Using River Water)

  • 박차식;김보현;김용찬;이영수;방기영
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1005-1013
    • /
    • 2005
  • The use of river water as a heat source of a heat pump has the advantage in the performance compared to the use of atmospheric air because the temperature variation of river water over the year is relatively small. In this study, the performance of the heat pump system using river water as a heat source was numerically investigated. A simulation model for the 2-stage compression heat pump system was developed with each component model composed of compressors, heat exchangers, a flash tank and electronic expansion devices. The peformance of the heat pump system using river water was improved by $50\%$ compared to that using atmospheric air in winter conditions.

산업용 냉각기의 압축기 회전수 변화에 따른 용량제어 특성 (The characteristics of capacity control using a variable speed compressor in an industrial cooler)

  • 백승문;문춘근;윤정인;정석권;김은필
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents the capacity-control characteristics in an industrial cooler with a variable speed compressor. The inverter-type compressor is controlled by the rotational speed of the operational frequency. This type of the compressor performs the wide range of load compared to the on-off type. When the load of the system reduces, the rotational speed will be reduced. Thus, the system leads to the less power consumption and extends the longer durability of the compressor. With the variable rotational speed of the compressor the cooling capacity of the cooler is about 1.6-3.6 kW and the capacity control is about 40-100%. The system showed the highest efficiency when the rotational speed is about 45-70 Hz. The results can be used as the basic design data to control an industrial cooler.

이산화탄소 급탕 열펌프의 난방 성능에 관한 실험적 연구 (Experimental Study on the Heating Performance of a $CO_2$ Heat Pump Water Heater)

  • 백창현;이응찬;강훈;김용찬;조홍현;조성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • In this study, experimental study on the heating performance of a $CO_2$ heat pump water heater with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening and water mass flow rate. Based on the test results, the optimum charge amount was 1800 g. At the water mass flow rates of 75, 85, 95 kg/hr, the water heating temperature was 62, 67, $74^{\circ}C$ and COP was 2.6, 2.8, 3.0, respectively. Besides, the water mass flow rate and compressor frequency were varied to maintain above the water heating temperature of $60^{\circ}C$ with the decrease of outdoor temperature. So, The compressor frequency increased beyond 65 Hz and the water mass flow rate was 45 kg/hr at the outdoor temperature of $-13^{\circ}C$, 65 kg/hr at $-8^{\circ}C$, 75 kg/hr at $-3^{\circ}C$ and 85 kg/hr at 2, $7^{\circ}C$. As the outdoor temperature decreased, the heating COP decreased by 2.5-39.8%.

  • PDF

Synthesis of Cathode Materials LiNi1-yCoyO2 from Various Starting Materials and their Electrochemical Properties

  • Song, Myoung-Youp;Rim, Ho;Bang, Eui-Yong;Kang, Seong-Gu;Chang, Soon-Ho
    • 한국세라믹학회지
    • /
    • 제40권6호
    • /
    • pp.507-512
    • /
    • 2003
  • The LiN $i_{l-y}$ $Co_{y}$ $O_2$ samples were synthesized at 80$0^{\circ}C$ and 85$0^{\circ}C$, by the solid-state reaction method, from the various starting materials LiOH, L $i_2$C $O_3$, NiO, NiC $O_3$, $Co_3$ $O_4$, CoC $O_3$, and their electrochemical properties are investigated. The LiN $i_{l-y}$ $Co_{y}$ $O_2$ pre-pared from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ exhibited the $\alpha$-NaFe $O_2$ structure of the rhombohedral system (space group; R3m). As the Co content increased, the lattice parameters a and c decreased. The reason is that the radius of Co ion is smaller than that of Ni ion. The increase in da shows that two-dimensional structure develops better as the Co content increases. The LiN $i_{0.7}$ $Co_{03}$. $O_2$[HOO(800,0.3)] synthesized at 80$0^{\circ}C$from LiOH, NiO, and $Co_3$ $O_4$ exhibited the largest first discharge capacity 162 mAh/g. The size of particles increases roughly as the valve of y increases. The samples with the larger particles have the larger first discharge capacities. The cycling performances of the samples with the first discharge capacity larger than 150 mAh/g were investigated. The LiN $i_{0.9}$ $Co_{0.1}$ $O_2$[COO(850,0.1)] synthesized at 85$0^{\circ}C$ from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ showed an excellent cycling performance. The sample with the larger first discharge capacity will be under the more severe lattice destruction, due to the expansion and contraction of the lattice during intercalation and deintercalation, than the sample with the smaller first discharge capacity. As the first discharge capacity increases, the capacity fading rate thus increases.increases.s.s.s.