• 제목/요약/키워드: Electronic-Equipment

검색결과 1,556건 처리시간 0.029초

배전반 시스템의 온라인 감시 및 진단 (On-line Monitoring and Diagnostics for Distribution Panel System)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.106-110
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

7차 교육과정에 따른 "전력 설비 II" 교과서의 편찬 방향 설정에 관한 연구 (A Study on the Establishment of Compilation Strategy Way of "Power equipment II" Textbook by 7th Technical High School Curriculum)

  • 박두기;조동헌;노명철;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.119-122
    • /
    • 2003
  • The purpose of this study is to find problems of "Electricity equipmentand" and "Electricity practic II" tectbook applied in 6th Technical High School Curriculum and to make direction of "Power equipment II" textbook applied in 7th Technical High School Curriculum. The method of this study is questionnaire survey. 120 teachers of 40 schools were selected by cluster sampling method. The main findings of this study are as follow. 1) We should make the composition of textbook easy. 2)The illustration, photograph and drawing of textbook are fitted well. 3) "power equipment II" textbook applied in 7th Technical High School Curriculum would contented follows : lighting equipment, elevator equipment, broadcasting equipment, interphone equipment.

  • PDF

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

배전반 설비의 온라인 모니터링 및 진단 (On-Line Condition Monitoring and Diagnostics of Distribution Equipment)

  • 윤주호;임완수;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

일반 굴삭기 장착 가능한 머신 컨트롤 키트 개발 및 성능 평가 (Development and performance evaluation of Machine Control Kit mountable to general excavators)

  • 이길수;김경수;정진범;박은성;고재일;박정종;주상현
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권1호
    • /
    • pp.31-37
    • /
    • 2024
  • In this study, to prevent accidents in underground facilities during excavation, we developed a Lv.3 automated control system that can be configured as an electronic control system without changing the existing hydraulic system in a general excavator and utilized digital map information of underground facilities. We aimed to develop a strategy to prevent accidents caused by operator error. To implement this, a real-time excavator bucket end position recognition and control system was developed through angle measurement of the boom, arm, and bucket using an electronic joystick, RTK-GPS, and angle sensors. In addition, excavators are large, machine-based equipment, and it is difficult to control overshoot due to inertia with feedback control using position recognition information of the bucket tip. Therefore, feed-forward control is used to calculate the moving speed of the bucket tip in real-time to determine the target position. We developed a technology that can converge and verified the performance of the developed system through actual vehicle installation and field tests.

반자장계수를 고려한 자성분말의 초투자율 측정에 관한 연구 (A Study on measuring the Initial Permeability of Magnetic Powder considered Demagnetizing factors)

  • 전홍배;허진;김철한;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.86-90
    • /
    • 2000
  • In this study, A equipment for measuring the initial permeability of soft-ferrite powder was developed by using a differential transformer coil, and was investigated demagnetizing factors. To measure the initial permeability of magnetic ceramic powder is cumbersome since there are not any measuring equipment and method. Magnetic powder is currently used for a magnetic fluid and microwave absorber materials, and the initial permeability of the magnetic powder is very important to be evaluated a powder for some applications.

  • PDF

정비작업의 생산성 향상을 위한 전자문서자동화시스템 모형 - 건설장비 정비작업을 중심으로 - (Electronic Document Automation System Model for Improving Productivity in maintenance work - in Inspection Process of Construction Equipment Maintenance -)

  • 공명달
    • 대한안전경영과학회지
    • /
    • 제19권3호
    • /
    • pp.49-58
    • /
    • 2017
  • This paper suggests a specific model that could efficiently improve the interaction and the interface between MES(Manufacturing Execution System) server and POP(Point of Production) terminal through electronic document server and electronic pen, bluetooth receiver and form paper in disassembly and process inspection works. The proposed model shows that the new method by electronic document automation system can more efficiently perform to reduce processing time for maintenance work, compared with the current approach by handwritten processing system. It is noted in case of the method by electronic document automation system that the effects of proposed model are as follows; (a) While the processing time per equipment for maintenance by the current method was 300 minutes, the processing time by the new method was 50 minutes. (b) While the processing error ratio by the current method was 20%, the error ratio by the new method was 1%.

반실험적 열소산 방법을 이용한 위성용 전장품 열해석 (A SATELLITE ELECTRONIC EQUIPMENT THERMAL ANALYSIS USING SEMI-EMPERICAL HEAT DISSIPATION METHOD)

  • 김정훈;전형열;양군호
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.32-39
    • /
    • 2006
  • A heat dissipation modeling method of EEE parts is developed for thermal design and analysis of an satellite electronic equipment. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is considered instead of conventional lumped capacity nodes. These modeling methods are applied to the thermal design and analysis of CTU EM and EQM and verified by thermal cycling and vacuum tests.

인공위성 전장품의 열설계 검증을 위한 해석 및 실험적 연구 (An Analysis and Experimental Study for Thermal Design Verification of Satellite Electronic Equipment)

  • 김정훈;전형열;양군호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.91-95
    • /
    • 2005
  • A heat dissipation modeling method of EEE parts is developed for thermal design and analysis of an satellite electronic equipment. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is developed instead of conventional lumped capacity nodes. The thermal plates are projected to the printed circuit board and can be modeled and modified easily by numerically preprocessing programs according to design changes. These modeling methods are applied to the thermal design and analysis of CTU and verified by thermal cycling and vacuum tests.

  • PDF

유해물질 사용제한에 따라 무연솔더링 공정으로 생산된 전자제품의 신뢰성확보 방안 (A study on the Reliability Assurance of the Electronic Equipment made with Lead-Free Solder - in the restriction of the use of hazardous substances -)

  • 송병석;조재립
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2004년도 품질경영모델을 통한 가치 창출
    • /
    • pp.298-301
    • /
    • 2004
  • European Union Member States shall ensure that, from 1 July 2006, new electrical and electronic equipment put on the market does not contain mercury, cadmium, lead, hexavalent chromium, polybrominated biphenyls(PBB) or polybrominated diphenyl ethers(PBDE) (by Directive 2002/95/EC of The European Parliament and the Council of 27 january, 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment ). So, It is important to develop lead free solder and to assure the reliability of appliance. But lead free solder(i.e. Sn-3Ag-0.5Cu) have some problems such as lift off, whisker, migration and crack, etc. In this paper we discuss the reliability assurance method in lead free solder and appliance.

  • PDF