• 제목/요약/키워드: Electronic waves

검색결과 296건 처리시간 0.035초

초박막 산화막 MOS 캐패시터에서 전자파 간섭의 극성 효과 (The polarity effect of electronic waves interference in the ultra thin oxide MOS capacitor)

  • 강정진
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.601-605
    • /
    • 1995
  • This study was concerned, after the oxide films(50 [.angs.]) were grown in a furnace and the MOS capacitor fabricated, with experimental comparison and verification about the Interference Effect of Electronic Waves in the ultra thin oxide/silicon interface. The average error was about 0.8404[%] in n'gate/p-sub and about 0.2991[%] in p$^{+}$gate/p-sub. Therefore, it was predicted that the Interference Effect of Electronic Waves can overcome somewhat according to the gate polarity.

  • PDF

복합 전도성 물질을 적용한 전자파 저감에 관한 연구 (Research about electromagnetic waves decrease that apply composition conductibility material)

  • 유희옥;윤정필;강병복;이정일;차인수;김민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.175-178
    • /
    • 2001
  • This treatise is treatise about interception effect of electromagnetic waves that is becoming social problem 21th century. Analyzed incidental and value comparison after used a widely spread computer mouse and electricity floor covered with laminated paper by materials for experiments, and apply composition conductibility electromagnetic waves cover material to this products, and limp an experiment in everyday life in this treatise.

  • PDF

제주지역 전자파 실태조사 및 영향평가 (Actual Condition Investigation and Effect Assessment of Electromagnetic Waves in Jeju Area)

  • 오성보;이개명;김세호;김영환;장시호;최병천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.130-132
    • /
    • 2005
  • In recent years, We have had many civil application about electromagnetic waves according to increasing of construction of electric power facilities. This paper describes human body effect by regulation management and the guidelines of human body protection of electromagnetic waves. We try to evaluate the effect of electromagnetic waves by actual measurement at wind power generation complexes in Hang-won, Jeju.

  • PDF

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

PZT압전 세라믹스의 종$\cdot$횡파 동시 발생 기구의 해석 (Analysis of Simultaneous Generation Mechanism of P/S Waves with the PZT Piezoelectric Ceramics)

  • 김연보;노용래;남효덕
    • 한국음향학회지
    • /
    • 제14권2호
    • /
    • pp.73-79
    • /
    • 1995
  • 현재 사용중인 초음파 트랜스듀서는 종피 또는 횡피 중 하나를 발생하도록 구성되어 있다. 본 연구는 단일 PZT소자로서 종파와 횡파를 동시에 발생 할 수 있는 2 중 모우드 트랜스듀서 의 초음파 발생 메커니즘을 조사하였다. 분극처리한 압전 세라믹 PZT의 결정구조는 상온에서 hexagonal (6mm) 이다. 트랜스듀서가 종. 횡액를 동시에 큰 강도로 발생하는 최적 절단면을 결정하기 위하여 PZT 소자의 효율을 회전각의 함수로 조사하였다 그리고 선택된 절단면에 대하여 소자의 임피던스 변화를 유한요소법으로 분석하고, pulse-echo 시뮬레이션으로 파형을 관찰하였다. 이론적 결과를 실험을 통해 확인하였다.

  • PDF

개인인증을 위한 뇌파의 재현성에 대한 분석 (Analysis of EEG Reproducibility for Personal Authentication)

  • 정유라;장윤석
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.527-532
    • /
    • 2020
  • 본 논문에서는 개인인증 시 활용 가능한 EEG 신호의 주파수 대역을 확인하기 위하여 뇌파 측정을 통해 분석한 결과를 제시하였다. 시각 과제의 유무에 따라 개안 상태와 폐안 상태로 구분하여 뇌파를 측정하였으며, 이를 델타파, 세타파, 알파파, SMR파, 중간베타파, 베타파 및 감마파의 7종류의 주파수 대역으로 나누어 시간에 따른 파워의 변동이 가장 작은 주파수 대역을 관찰하였다. 본 논문의 결과에서는 개안 상태와 폐안 상태에서는 유의한 차이가 나타나지 않았으나, 인간의 집중과 관련한 SMR파 및 중간베타파가 시간에 따른 파워의 변동이 가장 작게 관찰되었기에 재현성이 높은 주파수 대역인 것으로 나타났다.

시각자극 과제에 의한 집중 시의 뇌파분석 (Analysis of EEG Generated from Concentration by Visual Stimulus Task)

  • 장윤석;한재웅
    • 한국전자통신학회논문지
    • /
    • 제9권5호
    • /
    • pp.589-594
    • /
    • 2014
  • 인간은 집중할 때 유발되는 특정한 뇌파가 있는 것으로 알려져 있다. 본 논문에서는 인간의 집중과 관련된 뇌파를 분석하는 것을 목표로 하여, 집중을 유발할 수 있는 도구로 시각자극을 설정하였다. 즉 시각자극으로 구성된 과제를 제시하여 피험자가 집중할 수 있도록 하였다. 피험자로부터 유발되는 뇌파는 전극의 위치에 따른 채널별로 계측하였고, 계측한 뇌파는 주파수대역별로 나누어 분석하였다. 그 중에서도 특히 SMR, Mid-beta, Theta파에 해당되는 주파수대역의 파워 스펙트럼으로 분석하였고, 그 특성을 분석한 결과를 제시하였다.

동맥계 다채널 용적맥파 특징 파라미터 분석에 관한 연구 (Analysis of multi-channel photoplethysmograph parameter by the changes of arterial characteries)

  • 한순천;김형조;김형태;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2745-2748
    • /
    • 2003
  • In this paper, we implement the photoplethysmo-graphy system that have three channel pulse wave detects and one channel ECG amplifier. In order to detect the artery state, we measured the pulse waves at different positions, simultaneously. In general, arterial vascular system suffers the decrease of compliance, increase of resistance, and decrease of distensibility through aging. Therefore, we compared and analyzed variation of tile Pulse waves parameter both in time and frequency domains that is concerned with the changes of arterial characteries. And then evaluated the correlation coefficients between the parameters variation and the age group. As the result of experiment, we found that the Parameters have a significant correlation about aging.

  • PDF

Study of EMC Optimization of Automotive Electronic Components using ECAE

  • Kim, Tae-Ho;Kim, Mi-Ro;Jung, Sang-Yong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.248-251
    • /
    • 2014
  • As more vehicles become equipped with advanced electronic control systems, more consideration is needed with regards to automotive safety issues related to the effects of electromagnetic waves. Unwanted electromagnetic waves from the antenna, electricity and other electronic devices cause the performance and safety problem of automotive components. In general, Power Integrity and Signal Integrity analysis have been widely used, but these analyses have stayed PCB level. PCB base analysis is different from radiated emission TEST condition so its results are used just for reference. This paper proposes EMC optimization technology using module level 3-dimensional radiation simulation process closed to fundamental test conditions. If module level EMC analysis, which is proposed in this study, is applied to all automotive electronics systems, unexpected EMC noise will be prevented.