• Title/Summary/Keyword: Electronic waves

Search Result 295, Processing Time 0.102 seconds

The polarity effect of electronic waves interference in the ultra thin oxide MOS capacitor (초박막 산화막 MOS 캐패시터에서 전자파 간섭의 극성 효과)

  • 강정진
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.601-605
    • /
    • 1995
  • This study was concerned, after the oxide films(50 [.angs.]) were grown in a furnace and the MOS capacitor fabricated, with experimental comparison and verification about the Interference Effect of Electronic Waves in the ultra thin oxide/silicon interface. The average error was about 0.8404[%] in n'gate/p-sub and about 0.2991[%] in p$^{+}$gate/p-sub. Therefore, it was predicted that the Interference Effect of Electronic Waves can overcome somewhat according to the gate polarity.

  • PDF

Research about electromagnetic waves decrease that apply composition conductibility material (복합 전도성 물질을 적용한 전자파 저감에 관한 연구)

  • Yoo Hee-Ok;Yoon Jeong-Phil;Gang Byung-Bok;Lee Jeong-il;Cha In-Su;Kim Min
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.175-178
    • /
    • 2001
  • This treatise is treatise about interception effect of electromagnetic waves that is becoming social problem 21th century. Analyzed incidental and value comparison after used a widely spread computer mouse and electricity floor covered with laminated paper by materials for experiments, and apply composition conductibility electromagnetic waves cover material to this products, and limp an experiment in everyday life in this treatise.

  • PDF

Actual Condition Investigation and Effect Assessment of Electromagnetic Waves in Jeju Area (제주지역 전자파 실태조사 및 영향평가)

  • Oh, Seong-Bo;Lee, Kae-Myoung;Kim, Se-Ho;Kim, Young-Hwan;Jang, Si-Ho;Choi, Byung-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.130-132
    • /
    • 2005
  • In recent years, We have had many civil application about electromagnetic waves according to increasing of construction of electric power facilities. This paper describes human body effect by regulation management and the guidelines of human body protection of electromagnetic waves. We try to evaluate the effect of electromagnetic waves by actual measurement at wind power generation complexes in Hang-won, Jeju.

  • PDF

A Study on Thermo-Bed Design Development of HPT System (HPT 방식의 온열침대 디자인 개발에 관한 연구)

  • Lee, Bong-Kyu
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Analysis of Simultaneous Generation Mechanism of P/S Waves with the PZT Piezoelectric Ceramics (PZT압전 세라믹스의 종$\cdot$횡파 동시 발생 기구의 해석)

  • Kim, Yeon-Bo;Roh, Yong-Rae;Nam, Hyo-Duk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. A piezoelectric ceramic PZT has the hexagonal 6mm crystal symmetry, after poling. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and checking the wave form by pulse-echo test simulation. Validity of the theoretical calculation is verified through experiments.

  • PDF

Analysis of EEG Reproducibility for Personal Authentication (개인인증을 위한 뇌파의 재현성에 대한 분석)

  • Jung, Yu-Ra;Jang, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.527-532
    • /
    • 2020
  • In this paper, we presented the results of analysis through EEG measurement for the purpose of checking the frequency band of EEG signals that can be used for personal authentication. The measurement status was divided into the open-eye state and the closed-eye state depending on the presence or absence of an optical task. The data measured in the EEG experiments was divided into seven frequency bands : delta waves, theta waves, alpha waves, SMR waves, mid-beta waves, beta waves and gamma waves to identify the frequency band with the smallest power fluctuation over time. In our results, there was no significant difference between the open-eye state and the closed-eye state, and the SMR waves and mid-beta waves related to human concentration had the smallest fluctuation in power over time, and were a highly reproducible frequency band.

Analysis of EEG Generated from Concentration by Visual Stimulus Task (시각자극 과제에 의한 집중 시의 뇌파분석)

  • Jang, Yun-Seok;Han, Jae-Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.589-594
    • /
    • 2014
  • It has been known that the particular brain waves are induced when a human concentrates. In our study, we aimed to analysis the brain waves related to human concentration using visual stimulus to induce the concentration. The visual stimulus tasks were presented to subjects for concentration. We measured EEG signals with several channels and analyzed the signals into several frequency bands. In the measured EEG signals, we analyzed to focus on theta waves, SMR waves and mid-beta waves. Therefore we presented the results to investigate characteristics of the EEG signals related to the human concentration.

Analysis of multi-channel photoplethysmograph parameter by the changes of arterial characteries (동맥계 다채널 용적맥파 특징 파라미터 분석에 관한 연구)

  • Han, Soon-Chen;Kim, Hyoung-Jo;Kim, Hyoung-Tae;Kim, Jung-Kuk;Huh, Woong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2745-2748
    • /
    • 2003
  • In this paper, we implement the photoplethysmo-graphy system that have three channel pulse wave detects and one channel ECG amplifier. In order to detect the artery state, we measured the pulse waves at different positions, simultaneously. In general, arterial vascular system suffers the decrease of compliance, increase of resistance, and decrease of distensibility through aging. Therefore, we compared and analyzed variation of tile Pulse waves parameter both in time and frequency domains that is concerned with the changes of arterial characteries. And then evaluated the correlation coefficients between the parameters variation and the age group. As the result of experiment, we found that the Parameters have a significant correlation about aging.

  • PDF

Study of EMC Optimization of Automotive Electronic Components using ECAE

  • Kim, Tae-Ho;Kim, Mi-Ro;Jung, Sang-Yong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.248-251
    • /
    • 2014
  • As more vehicles become equipped with advanced electronic control systems, more consideration is needed with regards to automotive safety issues related to the effects of electromagnetic waves. Unwanted electromagnetic waves from the antenna, electricity and other electronic devices cause the performance and safety problem of automotive components. In general, Power Integrity and Signal Integrity analysis have been widely used, but these analyses have stayed PCB level. PCB base analysis is different from radiated emission TEST condition so its results are used just for reference. This paper proposes EMC optimization technology using module level 3-dimensional radiation simulation process closed to fundamental test conditions. If module level EMC analysis, which is proposed in this study, is applied to all automotive electronics systems, unexpected EMC noise will be prevented.