• 제목/요약/키워드: Electronic cooling system

검색결과 214건 처리시간 0.025초

테슬라(TESLA) 전기자동차 핵심 기술동향 (The Core Technical Trends of TESLA EV(Electric Vehicle) Motors)

  • 배진용;김용
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.414-422
    • /
    • 2017
  • This paper reviews the core technical trends of TESLA EV Motors. The TESLA EV Motors is explosively popular with a considerable recharging infrastructure, a wide 17-[inch] touch display, 417 [HP], and 378 [km] going distance. The object of this study analyzes the body appearance, motor and, battery cooling system, battery arrangement, battery management system, super charging station, power electronics, and induction motor.

I-123 핵종생산장치 시스템 설계 (Design of I-123 Nuclide Production System)

  • 정현우;유재준;김병일;이동훈
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1462-1468
    • /
    • 2014
  • 30MeV 사이클로트론의 양성자가 Xe-124 기체 표적 시스템에 조사될 때 일어나는 핵반응을 적용하여 Xe 가스를 GPM으로부터 타겟으로 전송하는 시스템을 설계하였다. 시스템 설계는 크게 4파트로 구성되며 각각의 하드웨어 부분은 솔리드웍스 3-D 캐드를 이용하여 설계하였다. 타겟 시스템 중 헬륨으로 Havor foil을 냉각시키게 설계했고, 타겟 내 Xe 가스가 양성자로 조사 시 상승하는 타겟 온도를 냉각수로 냉각시켜주도록 설계하였다. 또한, 온도센서와 압력센서를 장착하여 타겟 내의 온도와 압력을 확인할 수 있도록 구성 하였다. GPM은 Xe 가스를 타겟으로 운반, 준비하는 부분이며 Xe 가스를 저장하는 부분과 불순물을 제거하는 부분으로 구성되어 있다. HCS는 헬륨을 이용하여 각 파트를 세척하고 냉각시켜 주는 부분이며, 각각의 장치들은 PLC로 제어하여 유지보수시의 편리성을 추구하였고 PC Vue 모니터링 프로그램을 사용하여 SIEMENS PLC와 인터페이스 하여 시스템을 보다 안전하고 편리하게 감시하도록 구성하였다.

고발열 통신용 전자부품 냉각을 위한 고성능 수냉식 냉각판 개발에 관한 연구 (A Study on Development of Liquid Cooled Plate for Cooling of a Communication Electronic Device with High Heat Generation)

  • 장걸;박철민;김은필
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.26-31
    • /
    • 2007
  • 통신용 전자기기에서 대부분의 열은 증폭기에서 발생한다. 일반적으로 증폭기를 냉각하기 위하여 공랭식을 사용하여 발생하는 많은 열을 냉각하였다. 그러나 전통적인 방법은 고성능 콤팩트화 되어가는 추세에서 발열되는 열을 충분히 냉각하기는 부족하다. 본 논문은 고발열 전자부품 냉각을 위해서 수냉식 방법을 사용하였다. 열전달 효율을 높이기 위하여 냉각판에 직접 냉각수를 흐르게하여 접촉저항을 줄였다. 그리고 냉각판의 유로에 대한 배열과 유량의 비의 효과를 조사하였다. 연구를 수행한 결과, 다음과 같은 결론을 얻을 수 있었다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 냉각 성능이 10 mm일 때보다 우수한 것으로 나타났다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 발열 소자 표면 온도 분포가 더욱 안정적으로 나타났으며, 상하부에 설치된 발열 소자 표면 온도가 더 낮게 나타났다. 동일한 유로 직경의 냉각판에서, 열유속 증가에 따른 냉각수의 전열 성능 증가로 인해 전체 발열량의 증가율보다 발열 소자의 온도 증가율이 낮게 나타났다.

  • PDF

Cooling Characteristics of Sub-cooled Nitrogen Cryogenic System for 6.6kV/200A Inductive Fault Current Limiter

  • Hyoungku Kang;Bae, Duck-Kweon;Ahn, Min-Cheol;Kim, Hyung-Jin;Chang, Ho-Myung;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.57-61
    • /
    • 2003
  • In this investigation, the 6.6kV/200A Inductive Superconducting Fault Current Limiter (SFCL) was designed and fabricated. The type of DC reactor for Inductive SFCL was determined as solenoid type during the period of $1${st}$ year research. The 5 bobbins for DC reactor were fabricated and each bobbin was wound with 4 stacked High-Tc superconducting (HTS) tapes and the 5 bobbins were connected in series. The critical current and inductance of DC reactor were simulated by Finite Element method (FEM) and compared with the measured results. The characteristics of DC reactor were enhanced in sub-cooled nitrogen system rather than in liquid nitrogen system. The procedures to accomplish the sub-cooled nitrogen system and the experimental results were introduced in detail. Moreover, the design of sub-cooled nitrogen cryogenic system for next year research was introduced in brief.

EV 상용차용 히트펌프 시스템 냉방 운전 특성에 관한 연구 (A Study on Performance Characteristics of Heat Pump System on Cooling Mode for Light-duty Commercial Electric Vehicles)

  • 전한별;김정일;원헌주;이호성
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.69-75
    • /
    • 2019
  • 본 연구의 목적은 EV 경상용차에 적용되는 히트펌프 시스템에 대한 냉방 성능 특성을 실험적으로 분석하는 것이다. EV 경상용차가 운전되는 냉방 운전조건인 외기온도 35 ℃, 내기온도 25 ℃ 상황에서, 히트펌프 시스템의 냉방 특성을 분석하고자, 냉각수의 온도조건, 전동식 압축기 회전수 조건 변화에 대해서, 실험을 진행하였고, 그 결과를 분석하였다. 전동식 압축기 회전수가 증가할수록 냉방 성능이 평균 8.0 %가 증가하였고, 전동식 압축기 소비전력은 27 %가 증가하여서, 시스템 효율은 16.4 %가 감소하는 결과를 보여주고 있다. 전자장비 냉각을 위한 냉각수의 폐열을 활용하기 위하여서, 냉매랑 냉각수가 열교환 하는 칠러를 본 시스템에 적용하였다. 칠러에 적용되는 냉각수의 온도를 35 ℃에서 55℃로 변화시켰을 때, 응축 열원의 증가로 인하여서, 시스템 효율이 평균적으로 18.2 %가 떨어지는 결과를 보여주고 있다. 냉각수 유량 변화 측면에서, 운전 조건을 변화시켰지만, 냉방 성능에는 큰 변화를 보이고 있지 않았다. 향후, 냉각수 폐열을 사용하여서, 히트펌프 시스템에 대한 난방 성능 향상을 위한 연구가 필요한 상황에서, 관련 연구에 추가 할 예정이다.

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF

플라스틱 연료탱크 생산 설비에서의 소비 전력 저감을 위한 공조 시스템 설계 및 경제성 평가 (Design and Economics of HVAC System for Reduction of Power Consumption in Blow Mold Machine)

  • 이영재;최석천
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.84-93
    • /
    • 2017
  • This study was carried out to improve the electric power consumption of HVAC in the blow mold machine(BMM) and work environment. The experiment was conducted with the simulated HVAC system of 1/15 of the actual BMM. The temperature of main facility and two preheaters was fixed at 200 and $60^{\circ}C$ respectively in all test conditions. The measured points of temperature were chosen as critical locations considering the work environment. The tendency of temperature distributions decreases as the duct was closed to the main facility. The reduction rate of power consumption of HVAC increases up to 32.3% when both duct and cooling systems are operated. Also the efficiency of HVAC is improved about 9% through the modified design of duct system. It notes that the electric power consumption of HVAC can be reduced by the optimum design and operating condition of duct and cooling system.

운전조건 변화에 따른 이산화탄소 냉방시스템들의 성능 비교 (Comparisons of Performance in CO2 Systems with Operating Conditions)

  • 배경진;신은성;조홍현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1484-1490
    • /
    • 2009
  • Since the cooling performance of a $CO_2$ cooling cycle is varied significantly with a variation of refrigerant charge amount and outdoor temperature, the reliability of $CO_2$ system is down. In this study, the performance characteristics of three kinds of $CO_2$ systems were measured and analyzed by varying refrigerant charge amount and outdoor temperature so as to study the characteristics of variation with cycle option. The applied system options are the single-stage compression(1C-1E) system, two-stage compression with 1-EEV(2C-1E) system, and two-stage compression with 2-EEV(2C-2E) system. The performances of two-stage compression with 2-EEV system were less sensitive than those of other systems and the system operated safely and steadily for wide charge amount. The performance of the two-stage compression with 1-EEV(2C-1E) system was the most sensitive to the charge amount, and that of the single-stage compression(1C-1E) system varied a lot with outdoor temperature.

  • PDF

적분형 최적 레귤레이터 적용 시스템 히트펌프 제어 시뮬레이션 연구 (Numerical Simulation of a System Heat Pump Adopting an Integral Optimum Regulating Controller)

  • 김용찬;최종민
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.398-405
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system that utilizes package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance, along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only an easy distribution control, allowing free combination of indoor units with different models and different capacities, but also wide applications to intelligent air conditioning. However, the control algorithms of the system heat pump are limited in the open literature, due to complicated operating conditions. In this paper, an inverter-driven system heat pump having two indoor units with electronic expansion valves (EEV) was simulated in the cooling mode. An integral optimum regulating controller employing the state space control method was also simulated, and applied to the system-heat pump system, to obtain efficient control of the MIMO (multi input multi output) system. The simulation model for the controller yielded satisfactory prediction results. The new control model can be successfully utilized as a basic tool in controller design.