• Title/Summary/Keyword: Electronic Transformers

Search Result 216, Processing Time 0.029 seconds

Reliability Upgrading Technologies of Distribution Transformers (주상 변압기 신뢰성 향상기술)

  • Song, I.K.;Lee, B.S.;Jung, J.W.;Kim, D.M.;Kim, J.Y.;Lee, J.B.;Kwon, T.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.212-215
    • /
    • 2003
  • In this paper, a model pole transformer was designed to improve the reliability of pole transformers and its short circuit withstand strength was tested. The failure causes of the pole transformers which had been operated in the field were analyzed and several patterns of the causes were determined. A novel countermeasure was devised to prevent the failures of the pole transformers in advance. A model pole transformer was designed and made in accordance with the given specifications to strengthen the short circuit withstand capability and its characteristic was tested. As a result, the advanced performance of the model pole transformer was confirmed and novel techniques in manufacturing process was suggested. It is considered that all the methods employed in the developing process will be helpful to design and manufacture the pole transformers thus the reliability of pole transformers in distribution lines will be improved.

  • PDF

Electrical Properties of Rosen Type piezoelectric transformers using Low Temperature Sintering PMN-PNN-PZT ceramics (저온소결 PMN-PNN-PZT계 세라믹스를 이용한 Rosen형 압전변압기의 전기적 특성)

  • Lee, Sang-Ho;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.53-53
    • /
    • 2008
  • Piezoelectric transformers have been widely used such as DC-DC convertor, invertor, Ballast, etc. Because, the y have some merits compared with electro-magnetic transformers such as step-up ratio, high efficiency, small size and lg hit weight, etc. Piezoelectric transformer require high electromechanical coupling factor kp in order to induce a large out put power in proportional to applied electric field. And also, high mechanical quality factor Qm is required to prevent mechanical loss and heat generation. In general, PZT system ceramics should be sintered at high temperatures between 1200 and $1300^{\circ}C$ in order to obtain complete densification. Accordingly, environmental pollution due to its PbO evaporation. Hence, to reduce its sintering temperature, various kinds of material processing methods such as hot pressing, high energy mill, liquid phase sintering, and using ultra fine powder have been performed. Among these methods, liquid phase sintering is basically an effective method for aiding densification at low temperature. In this study, In order to comparis on low temperature sintering and solid state sintering piezoelectric transformers, rosen type transformers were fabricated u sing two PZT ceramics compositions and their electrical properties were investigated.

  • PDF

Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission (무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작)

  • Kim, Sung-Tae;Cha, Doo-Yeol;Kang, Min-Suck;Cho, Se-Jun;Jang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

Design and FEM Analysis of Unipoled Disk-type Piezoelectric Transformer (Unipoled Disk-type 압전변압기의 설계 및 유한요소 해석)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.183-186
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed 2~7 times higher voltage step-up ratio than a experiment result.

  • PDF

Diagnostic techniques of aging deterioration of power transformer by insulating paper (절연지에 의한 전력용변압기 열화진단 기술)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yoon, Yeo-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.449-452
    • /
    • 2004
  • The life of power transformer is basically dependent on the aging deterioration of insulating paper. Analysis of insulating paper for its DP value or tensile strength requires removal of a few strips of paper but direct measurement of this properties is not practical for in-service transformers. For this reason furfural analysis by HPLC has gained increasing favor as a means of estimating degradation of insulating papers in power transformers and this paper reports on the analysis of data on the concentration of furfural in oil samples from about 50 power transformers and the case study. The data showed that furfural content can estimate more accurately aging characteristics compared to concentration of CO, $CO_2$. We expect that these results can be useful to predict the aging characteristics and life diagnosis of power transformers and further the study must be continued.

  • PDF

Design and ANSYS Analysis of Disk-type Piezoelectric Transformer (디스크형 압전변압기의 설계 및 유한요소 해석)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.813-816
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed $2\sim7$ times higher voltage step-up ratio than a experiment result.

  • PDF

A Study on the New Evaluation Method on Insulation of Electronic Components (전자부품의 새로운 절연평가기법 연구)

  • Kil, Gyung-Suk;Snog, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

Transformation Characteristics of Multi layed Ring-dot type Piezo Transformer (적층형 Ring-dot type 압전변압기의 변압특성)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.671-674
    • /
    • 2004
  • This paper presents design and analysis of multi-layered ring-dot type piezoelectric transformer. These transformers are useful for step up and step down. The transformers consist of disk type multi-layered piezoelectric ceramic plates. The finite element method(FEM) was used for analysis transformer. Vibration mode, electric field and equivalent elastic strain of piezoelectric transformer were simulated by changing frequency. As results, the strain was distributed in isolation part entirely. We can get the operated in step up transformer when the inner side electrode using by input parts. Also we can get the step down transformers using by input Part as outer side electrode. The step up ratio and step down ratio was increased by decreasing inner side electrode. The resonance frequency was increased by increasing inner side electrode when the transformer was operated in step down transformer. But the step up one was decreased. From these results, we can expect to multi-layered ring-dot type piezo transformers as step up and step down transformers.

  • PDF

Investigation of facto~ in square-type piezoelectric transformer using ATILA simulation (ATILA 시뮬레이션을 이용한 스퀘어타입 압전변압기의 펙터연구)

  • Vo, Vietthang;Kim, In-Sung;Joo, Hyeon-Kyu;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.327-327
    • /
    • 2010
  • In this paper, an investigation of factors affecting piezoelectric transformers is presented by ATILA software. These transformers are multi-layer piezoelectric transformers in square shape $28\;{\times}\;28\;mm$ and operate in first vibration mode for step-down function. The piezoelectric transformers were modeled in 3D-dimension and analyzed using finite element method in ATILA software, a popular software in piezoelectric analysis. Modal and harmonic modules were used in this process. Effective factors to the properties of piezoelectric transformers including different input electrode patterns, directions of polarization, sizes of connective comer, number of layers were examined on the simulated model using input voltage of 20 V and load resistance of $100\;{\Omega}$. Moreover, thermal analysis was also obtained with conditions of input voltage of 5 V and no-load.

  • PDF

Fabrication of the Micromachined Transformer using High Permeability NiFe Core (투자율이 높은 NiFe 코어를 이용한 마이크로 트랜스포머 제작)

  • Cho, Se-Jun;Cha, Doo-Yeol;Lee, Jai-Hyuk;Lee, Soo-Jin;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.194-198
    • /
    • 2010
  • Recently as the electronic devices are getting to be more and more smaller, transformers are needed to be micro fabricated using MEMS technology. In this paper transformers have been fabricated and measured by depositing insulation layer to reduce the loss of eddy current and in the middle core a high permeability permalloy was designed based on the turns ratio between primary coil and secondary coil which are 1:1 transformers. (the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7). The size of the transformers including ground shield are $1mm{\times}1.5mm$, $1mm{\times}1.95mm$, $1mm{\times}2.35mm$ respectively. The line width, pitch and the height of post are 50um. Based on the measured data from the micro fabricated transformers, the 3/3 turns in the primary coil and secondary coil showed the lowest insertion loss with 1.5 dB at 480 MHz and the 7/7 turns in the primary coil and secondary coil showed the highest insertion loss with 2.5 dB at 280 MHz. Also confirmed that the bandwidth goes up as the number of turns goes down. There was some difference between the actual measured data and the HFSS simulation result. It looks as if it is an error of the difference between oxidation of copper or the permeability of SU-8.