• 제목/요약/키워드: Electronic Speckle Pattern Interferometry(ESPI)

검색결과 114건 처리시간 0.025초

진동해석을 위한 전자전단간섭계의 개발 (Development of electronic shearography for vibration analysis)

  • 강영준;권용기
    • 대한기계학회논문집A
    • /
    • 제21권12호
    • /
    • pp.2047-2054
    • /
    • 1997
  • This paper describes a measuring method of vibration mode shapes by the Electronic Shearography. This method called the speckle interferometer has many merits in practical use, such as low sensitivity to environmental noise, low limit of coherent-length and simple optical configuration. In this study, we developed Michelson-type shearing interferometer provided with a phase stepping mirror and with a bias modulation mirror to quantify the vibration gradient fields. Results of application to a simple cantilever plate show that the vibration amplitude fields obtained are in good agreement with those of the electronic speckle pattern interferometry (ESPI).

전자처리스페클패턴 간섭법을 이용한 평판 용접시험편의 잔류응력 측정 (Residual Stress Measurement of Flat Welded Specimen by Electronic Speckle Pattern Interferometry)

  • 장호섭;김동수;정현철;김경석
    • 비파괴검사학회지
    • /
    • 제32권2호
    • /
    • pp.149-154
    • /
    • 2012
  • 용접구조물에는 외력이 부가되기 이전에 잔류응력이 걸려 있으므로 용접잔류응력 크기 및 분포 상태는 취성파괴, 피로강도, 응력부식균열, 좌굴, 시효변형과 같은 다양한 형태의 손상에 직접적으로 영향을 끼쳐 잔류응력을 정량적으로 해석하기 위한 지속적인 연구가 필요한 실정이다. 본 논문은 비파괴적인 기법 중 레이저를 이용한 전자처리스페클패턴 간섭법을 이용하여 평판 용접시험편의 외부하중에 따른 전체 거동에 잔류응력의 측정 기법을 제시하고자 한다. 용접시험편에 인장 하중을 가하였을 때, 이를 전자처리패턴스페클 기법을 이용하여 측정하였다. 측정된 결과로부터 용접시험편의 모재부와 용접부의 변형률을 측정하고, 이를 이용하여 탄성계수를 측정하였다. 본 논문은 전자처리스페클패턴 간섭법으로 용접시험편의 용접부와 모재부의 변형률의 차이를 이용하여 잔류응력 값을 산출하는 식을 제시하였고, 이를 수치적으로 계산하여 잔류응력 값을 산출하였으며 측정 결과, 모재부에 비해 용접부의 탄성계수가 약 3.7배 높은 약 8.46 MPa로 측정되었다.

레이저스펙클 간섭법과 4단계 위상이동법에 의한 외팔보점용접부의 면외 변위측정 (Measurement of Out-of-plane Displacement in a Spot Welded Canti-levered Plate using Laser Speckle Interferometry with 4-step Phase Shifting Technique)

  • 백태현;김명수;차병석;조성호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.226-230
    • /
    • 2001
  • Electronic Speckle Pattern Interferometry (ESPI) has been recently developed and widely used because it has advantage to be able to measure surface deformations of engineering components and materials in industrial areas with non-contact. The spekle patterns to be formed with interference phenomena of scattering phenomena measure the out-of-plane deformations, together with the use of digital image equipment to process the informations included in the speckle patterns and the display consequent interferogram on a computer monitor. In this study, the experimental results of a canti-levered plate using ESPI were compared with those obtained from the simple beam theory. The ESPI results of the canti-levered plate analyzed by 4-step phase shifting method are close to the theoretical expectation. Also, out-0of-plane displacements of a spot welded canti-levered plate were measured by ESPI with 4-step phase shifting technique. The phase map of the spot welded canti-levered plate is quite different from that of the canti-levered plate without spot welding.

  • PDF

모듈레이팅 레이저를 이용한 ESPI 시스템 개발 (Development of ESPI System Using a Modulating LASER)

  • 이근영;강영준;박낙규;이동환
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.93-100
    • /
    • 2008
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and ability to measure a broad area in real-time all at once. In conventional LASER interferometry, for example Out-of-plane ESPI(Electronic Speckle Pattern Interferometry), In plane ESPI, Shearography and Holography, it uses PZT or other components as a phase shift instrumentation to extract 3D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of LASER interferometry using a laser diode is proposed. Using LASER Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the LASER Diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD Modulating interferometry that involves four-buckets phase shift method. This study proposes a four-bucket phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Four-bucket phase mapping algorithm is then introduced.

TA-ESPI에 의한 외팔보의 탄성계수 측정 (Evaluation of Young's Modulus of a Cantilever Beam by TA-ESPI)

  • 이항서;김경석;강기수;정현철;양승필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1115-1119
    • /
    • 2005
  • The paper proposes the elastic modulus evaluation technique of a cantilever beam by vibration analysis based on time-average electronic speckle pattern interferometry (TA-ESPI) with non-contact and nondestructive and Euler-Bernoulli equation. General approaches for the measurement of elastic modulus of thin film are Nano indentation test, Bulge test and Micro-tensile test and so on. They each have strength and weakness in the preparation of test specimen and the analysis of experimental result. ESPI has been developed as a common measurement method for vibration mode visualization and surface displacement. Whole-field vibration mode shape (surface displacement distribution) at a resonance frequency can be visualized by ESPI. And the maximum surface displacement distribution from ESPI is a clue to find the resonance frequency at each vibration mode shape. And the elastic modules of test material can be easily estimated from the measured resonance frequency and Euler-Bernoulli equation. The TA-ESPI vibration analysis technique is able to give the elastic modulus of materials through the simple processing of preparation and analysis.

  • PDF

마이크로 ESPI기법을 이용한 동 박막의 인장 특성 측정 (Measurement of Tensile Properties of Copper Foil using Micro-ESPI Technique)

  • 김동일;허용학;기창두
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.89-96
    • /
    • 2004
  • Micro-tensile testing system, consisting of a micro tensile loading system and micro-ESPI(Electronic Speckle Pattern Interferometry) system, has been developed for measurement of micro-tensile properties of thin micro-materials. Micro-tensile loading system had a load cell with the maximum capacity of 50N and micro actuator with resolution of 4.5nm in stroke. The system was used to apply a tensile load to the micro-sized specimen. During tensile loading, the micro-ESPI system acquired interferornetric speckle patterns in the deformed specimen and measured the in-plane tensile strain. The ESPI system consisted of a CCD-camera with a lens and the window-based program developed for this experiment. Using this system, stress-strain curves for 4 kinds of electrolytic copper foil 18$\square$m thick were obtained. From these curves, tensile properties, including the elastic modulus. yielding strength and tensile strength, were determined and also values of the plastic exponent and coefficient based on Ramberg-Osgood relationship were evaluated.

전자처리 스페클 패턴 간섭법(ESPI)을 이용한 3-유닛 고정성 국소의치의 변형특성 분석 (Deformation Characteristics Analysis of 3-Unit Fixed Partial Dentures by Using Electronic Speckle Pattern Interferometry)

  • 강후원;이철민;양승필;김희진
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.49-56
    • /
    • 2013
  • Purpose: The deformation characteristics induced by non-destructive stresses using piezoelectric transducer(PZT) were analyzed for 3-unit fixed partial dentures manufactured PFM, Everest(CAD/CAM) and Zirkonzahn(copy milling, MAD/MAM) by electron speckle pattern interferometery(ESPI). Methods: The ESPI analysis after loading the restoration with PZT by applying electric voltage of 900mV at the points of 10 mm above the base of the prostheses. Results: PFM and All-Ceramic Everest prostheses showed about 0.1 ${\mu}m$ while that of All- Ceramic Zirkonzahn prostheses showed 0.085 ${\mu}m$, demonstrating that Zirkonzahn displaced less. For PFM and All-Ceramic Zirkonzahn prostheses, the displacements were large at just below the loading point, while generalize displacement was shown over the loading point and weak connector areas for All-Ceramic Everest prostheses. Conclusion: We could find that the deformation characteristics induced by non-destructive stresses using PZT analyzed by ESPI were similar to the fracture strengths evaluated using universal testing machine.

ESPI에 의한 원공판의 2차원 면내변위 측정에 관한 연구 (A study on the measurement of two-dimensional in-plane displacements of the plate with a circular hole by ESPI method)

  • 김경석;최형철;양승필;김형수;홍명석;정운관
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.161-170
    • /
    • 1994
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interfermetry(ESPI) method, in measuring two-dimensional in- plane displacement. The analysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversial point, measurement error. This error is discussed to be affected not by ESPI method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. Further development of advanced first-order interpolation method is being undertaken for the more precise in-plane strain measurement.

  • PDF

ESPI와 음향공진법을 이용한 Foil 재료의 동적탄성계수 측정 (Measurement of Dynamic Elastic Modulus of Foil Material by ESPI and Sonic Resonance Testing)

  • 이항서;김경석;강기수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.914-917
    • /
    • 2005
  • The paper proposes a new sonic resonance test for a dynamic elastic constant measurement which is based on time-average electronic speckle pattern interferometry(TA-ESPI)and Euler-Bernoulli equation. Previous measurement technique of dynamic elastic constant has the limitation of application for thin film or polymer material because contact to specimen affects the result. TA-ESPI has been developed as a non-contact optical measurement technique which can visualize resonance vibration mode shapes with whole-field. The maximum vibration amplitude at each vibration mode shape is a clue to find the resonance frequencies. The dynamic elastic constant of test material can be easily estimated from Euler-Bernoulli equation using the measured resonance frequencies. The TA-ESPI dynamic elastic constant measurement technique is able to give high accurate elastic modulus of materials through a simple experiment and analysis.

  • PDF