• Title/Summary/Keyword: Electronic Load

Search Result 1,285, Processing Time 0.032 seconds

A Study on the High-Voltage Measuring & Control System for a Load Switch (부하개폐기용 고전압 계측제어 장치에 관한 연구)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.757-759
    • /
    • 1998
  • This paper proposes a new high-voltage measuring system that is able to provide current enough to charge a storage battery for a motor driving a load switch, and detect each phase voltage and phase angle in three phase distribution line accurately. In order to develop the reliable voltage measuring system we had designed and manufactured condenser-type bushing having good characteristics for temperature on account of using epoxy resin as dielectric material, and investigated the variation characteristics of capacitance via variation of applied voltage. The experiment results show that the proposed condenser has good characteristics to environmental changes.

  • PDF

Heat and Flow Analysis on Cabin Room of Battle Tank (전차 포탑 승무원실의 내부 열/유동장에 관한 수치적 연구)

  • NamKoung, H.J.;Lee, K.H.;Park, B.H.;Roh, K.L.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.5-10
    • /
    • 2006
  • The heavy thermal load to battle tanks can cause electronic components' malfunction and crew to be put out of action. The thermal load is generated from Internal heat sources such as electronic devices installed in the room as well as extremely hot weather. In this study, heat and flow analysis for the cabin room of a battle tank was performed to deal with this thermal problem. This study presented the validation of simulation results in comparison with those of test, the investigation of optimal flow design for effective cooling in cabin room and finally the evaluation of thermal comforts to crew.

An Intelligent Fault Detection and Service Restoration Scheme for Ungrounded Distribution Systems

  • Yu, Fei;Kim, Tae-Wan;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Sung-Il;Lee, Sung-Woo;Ha, Bok-Nam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.331-336
    • /
    • 2008
  • Electric load components have different characteristics according to the variation of voltage and frequency. This paper presents the load modeling of an electric locomotive by the parameter identification method. The proposed method for load modeling is very simple and easy for application. The proposed load model of the electric locomotive is represented by the combination of the loads that have static and dynamic characteristics. This load modeling is applied to the KTX in Korea to verify the effectiveness of the proposed method. The results of proposed load modeling by the parameter identification follow the field measurements very exactly.

Development and Performance Evaluation of Falling-type Dried-Persimmon Weight Sorting System Utilizing Load Cell

  • Lim, Jongguk;Kim, Giyoung;Mo, Changyeun;Choi, Inchul
    • Journal of Biosystems Engineering
    • /
    • v.40 no.4
    • /
    • pp.327-334
    • /
    • 2015
  • Purpose: A falling-type weight sorter equipped with a load cell was developed to sort lightweight dried persimmons. The performance of the sorter was also evaluated. Methods: The electronic weight sorter for dried persimmon comprises a feeder part, a weight-measurement part, an indicator part, a carrier cup, a discharging part, and a driving part. The weight setting and zero-point adjustment are performed digitally for the convenience of users. For the experimental trials, 228 rubber-clay specimens (representative of dried persimmons) in the weight range of 24.73~99.56 g were manufactured for use in experiments to evaluate the performance of the sorter. Results: The average error of the weight measurements from three experimental trials was 1.655%, with a bias of -0.492 g, a root-mean-square error (RMSE) of ${\pm}0.808g$, and a coefficient of determination ($R^2$ ) of 0.997. Conclusions: The load-cell-based electronic dried-persimmon weight sorter developed in this study facilitates effective, precise, and convenient sorting of dried persimmons.

Load-Pull Measurement for High Power, High Efficiency PA Design (고출력, 고효율 PA 설계를 위한 로드-풀 측정)

  • Lim, Eun-Jae;Lee, Gyeong-Bo;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.945-952
    • /
    • 2015
  • Power amplification device which is matched to $50{\Omega}$ in order to achieve a high efficiency of a power amplifier using a GaN power amplification device, since there is a limit of application frequency bands, output power, efficiency characteristics selection, in this study based on the measurement data through the source/load-pull test, high output power and to extract quantitative input and output impedance that matches the design objectives of high output power, high efficiency, an implementation of the high efficiency power amplifier. Implemented power amplifier is shows 25watt(44dBm), PAE of 66-76% characteristics in the frequency band of 2.7-3.1 GHz.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

A study on the Maximum Power Point Tracking Control System of Wind Power Generation (풍력발전의 최대전력점 추종제어 방법에 관한 연구)

  • Ko, Seok-Cheol;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking (MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems (배전원격관리를 위한 차세대 디지털 적산전력계 개발)

  • 고윤석;윤상문;서성진;강태규
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.