• 제목/요약/키워드: Electronic Heating

Search Result 512, Processing Time 0.03 seconds

Fabrication of a polymerase chain reaction micro-reactor using infrared heating

  • Im, Ki-Sik;Eun, Duk-Soo;Kong, Seong-Ho;Shin, Jang-Kyoo;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.337-342
    • /
    • 2005
  • A silicon-based micro-reactor to amplify small amount of deoxyribonucleic acid (DNA) has been fabricated using micro-electro-mechanical systems (MEMS) technology. Polymerase chain reaction (PCR) of DNA requires a precise and rapid temperature control. A Pt sensor is integrated directly in the chamber for real-time temperature measurement and an infrared lamp is used as external heating source for non-contact and rapid heating. In addition to the real-time temperature sensing, PCR needs a rapid thermocycling for effective PCR. For a fast thermal response, the thermal mass of the reactor chamber is minimized by removal of bulk silicon volume around the reactor using double-side KOH etching. The transparent optical property of silicon in the infrared wavelength range provides an efficient absorption of thermal energy into the reacting sample without being absorbed by silicon reactor chamber. It is confirmed that the fabricated micro-reactor could be heated up in less than 30 sec to the denaturation temperature by the external infrared lamp and cooled down in 30 sec to the annealing temperature by passive cooling.

Fabrication on Microheater Flow Sensors Using Membrane Structure and Its Characteristics (맴브레인 구조를 이용한 미세발열체형 유량센서의 제작과 그 특성)

  • 정귀상;노상수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.996-1000
    • /
    • 1998
  • This paper describes the characteristics of Pt microheater using aluminum oxide films as medium layer and its application to flow sensors. Pt microheater have heating temperature of $390^{\circ}C$ at heating power of 1.2 W. Output voltages of flow sensors which were fabricated by integrating sensing-part with heating-part increase as gas flow rate and its conductivity increase. At $O_2$ flow rate of 2000 sccm, heating power of 0.8 W, output voltage of flow sensor is 101 mV under bridge-applied voltage of 5 V.

  • PDF

A Study on the Temperature-Diffusion Analysis of Induction Heating Jar (Induction Heating Jar의 온도분포 해석에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok;Lee, Bong-Seob;Lee, Young-Mee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.79-82
    • /
    • 2002
  • Induction heating is widely used in today's industry, in operations such as metal hardening, preheating for forging operations, melting or cooking. In this paper, it was presented the magneto-thermal analysis of an induction heating jar(IH-JAR) with the material value of the stainless and the aluminum for efficient design. The magnetic field intensity inside the axisymmetric shaped cooker was analyzed using three-dimensional axisymmetric finite element method(FEM) and the effectual heat source was obtained by ohmic losses from eddy currents induced in the jar. The heat was calculated using the heat source and heating equation. Also, it was represented the temperature characteristics of the IH-JAR according to time and relative permeability in stainless parts and in aluminum parts.

  • PDF

A Study on Magnetic Cure System Depending on Dominant Direction of Meridian using Heating Diagnosis Method

  • Kim, Byoung-Hwa;Lee, Hie-Soung;Lee, Woo-Cheol;Han, Gueon-Sang;Won, You-Seub;Sagong, Seok-Jin;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1776-1779
    • /
    • 2002
  • In this paper, we measured the heating time on the key measuring point of the meridian of the human body's left and right by using heating machine. Then, based on the fuzzy theory, this study diagnosed the each meridian's strength and weakness, After that, both the strengthening and weakening stimulus of magnetic field was applied to the dominant direction to find out how the degree of strength and weakness of the meridian changed. Ultimately, the magnetic therapy that can stimulate the magnetic field at the time of diagnosis and thereby balancing the interactive of a five system has been materialized. For the stimulation of magnetic field, a stimulating device which can change the direction and time on a specific part of the key measuring points has been developed and used. The therapeutic method is as follows. first, the strength and weakness of the meridian has been determined. Second, both the extremely weak meridian of Yin(Shade) and Yang(Shine), and the extremely strong meridian of Yin and Yang were adjusted by applying appropriate ascending and descending stimuli respectively.

  • PDF

A Study on the Characteristics of Management Costs of Apartment Complexes by the Types of Heating Systems (난방방식에 따른 아파트 관리비용의 실태에 관한 연구 - 대전광역시를 대상으로 -)

  • Koh, Bong-Sung;Kim, Sang-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.607-615
    • /
    • 2012
  • The aim of the study is to estimate the management costs of apartments by the types of heating systems(individual, central, district heating system). Multiple regression analysis was adapted and the used data are derived from 128 apartment complexes in Daegeon-si. The results are as follows; first, the management cost is decreased as a size of apartment is larger, second, the costs of general maintenance, security and repairing of buildings are lower in individual heating system. however, there is no significant differences in cleaning costs by the types of heating systems.

Co-firing of Dielectric and Electrode with Conventional and Microwave Heating in Plasma Display Panel (전형적인 열처리와 마이크로웨이브 열처리에 따른 PDP용 전극과 투명 유전체의 동시 소성)

  • Hwang, Seong-Jin;Veronesi, Paolo;Leonelli, Cristina;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.463-463
    • /
    • 2008
  • The glass frit has been used in transparent dielectric, barrier rib and electrode of PDP (Plasma display panel). In PDP fabrication, the firing temperature of glass frit is normally 550~$580^{\circ}C$ with conventional heating. However, there are a problem that silver in electrode is diffused throughout the transparent dielectric. For inhibiting the Ag diffusion we considered use of the microwave heating. We investigated firing of glass frit compared between conventional and microwave heating. After firing by two types of heating, the diffusion of silver is determined using a optical microscope and UV-spectrometer. Based on the our results, the microwave heating should be a candidate to heating source for high efficacy in PDP.

  • PDF

Study on Pultrusion of FRP by Dielectric Heating (유전가열에 의한 FRP의 인발성형 연구)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.445-448
    • /
    • 2004
  • Radio frequency and microwave dielectric heating are well-known electroheating methods, used in industrial applications where non electrically conducting materials are to be heated, dried or otherwise processed. The major reason for considering this technique for any process is based on its unique ability to transfer heat into the volume of an electrically non conducting material such as insulator directly, rather than, via a surface. Conventional heating must first bring heat to the product surface and there after it depends on the physical characteristics and condition of the material as to how effectively this heat is transmitted into the mass. The product would suffer surface damage before the main body is adequately processed. Dielectric heating is applied to enhance conventional heating methods and to drastically shorten the required processing duration. Although the use of dielectric heating has been a well proven technique for several years in some industries, its application in the preheating of FRP has been limited by the insufficient experience. In this paper a method is described for uniform radio frequency heating of preheating of FRP.

  • PDF

The Electronic Laser Interferometry and Laser Heating Method for Residual Stress Determination

  • Kim, Koung-Suk;Kang, Young-June;Rho, Kyung-Wan;Ryu, Weon-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.7
    • /
    • pp.715-721
    • /
    • 2000
  • Residual stress is one of the causes which makes defects in engineering components and materials. These residual stresses can occur in many engineering structures and can sometimes lead to premature failures. There are commonly used methods by which residual stresses are currently measured. But these methods have a little damage and other problems; therefore, a new experimental technique has been devised to measure residual stress in materials with a combination of electronic laser interferometry, laser heating and finite element method. The electronic laser interferometer measures in-plane deformations while the laser heating and cooling provides for very localized stress relief. FEM is used for determining the heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heat-up and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method.

  • PDF

Microwave Sintering of Silver Thick Film on Glass Substrate (유리기판 위에 Ag 후막의 마이크로웨이브 소결)

  • Hwang, Seong-Jin;Veronesi, Paolo;Leonelli, Cristina;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.22-22
    • /
    • 2009
  • The silver thick film has been used in many industries such as display, chip, solar cell, automobile, and decoration with conventional heating. The silver thick film is fired with optimal time and temperature. However, decreasing the fabrication time is required due to high production power. Furthermore, there is a problem that silver in electrode is diffused throughout any substrates. For inhibiting the Ag diffusion and long fabrication time we considered a microwave heating. We investigated firing of silver thick film with conventional and microwave heating. The temperature of substrate was measured by thermal paper and the temperature of substrate was under $100\;^{\circ}C$ The shrinkage of electrode was measured with optical microscopy and optical profilometry. The shrinkage of electrode heat treated with microwave for 5min was similar to the that fired by the conventional heating for several hours. After firing by two types of heating, the diffusion of silver was determined using a optical microscope. The microstructure of sintered silver thick film was observed by SEM. Based on our results, the microwave heating should be a candidate heating source for the fabrication electronic devices in terms of saving the tact time and preventing the contamination of substrate.

  • PDF

A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection (분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang;Choi, Yong-Sung;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF