• Title/Summary/Keyword: Electron beam accelerator

Search Result 161, Processing Time 0.032 seconds

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

Effects of Cooking Method and Temperature on the Lipid Oxidation of Electron-Beam Irradiated Hanwoo Steak. (가열방법 및 온도가 전자선 조사한 한우 steak의 지질산화에 미치는 영향)

  • Park T. S.;Shin T. S.;Lee J. I.;Park G. B.
    • Journal of Life Science
    • /
    • v.15 no.5 s.72
    • /
    • pp.840-846
    • /
    • 2005
  • This study was carried out to investigate the effect of electron beam irradiation and cooking temperature on physico-chemical characteristics and lipid oxidation of beef. A total of six beef carcasses ($280\∼300 kg$) that were quality grade $1^{+}$(marbling score No.7, meat color No.4, maturity No.1, texture No.1) was purchased at the commercial slaughter house. The carcasses were transported and washed using high pressure water, and pasteulized with $ 50\% $ ethyl alcohol in the laboratory. After the carcasses were deboned and trimmed, loin and round were taken out to make steak (1.5cm thickness) or ground beef respectively. Samples were wrap or vacuum packaged and irradiated with 0, 3, 4.5, 6 and 7.5 kGy using electron-beam accelerator at Samsung Heavy Industries Ltd. Co. (in Taejun). Irradiated samples were cooked with different methods(electronic pan and gas oven) and temperatures ($ 60^{\circ}C, 70^{\circ}C and 80^{\circ}C$) and used to measure fatty acid composition, TBARS, cholesterol oxide products and panel test scores. The content of saturated fatty acids increased by increasing heating temperature in oven boiling steak (OBS) and pan boiling steak (PBS), and there was no difference by electron-beam irradiation. Both irradiated and non-irradiated treatment were high as the heating temperature increased in TBARS by heating temperature in PBS (p < 0.05) and the amount of Malonaldehyde (MA), standard of fat deterioration, was increased in OBS (p < 0.05). Non-irradiated and 3, 6 kGy treatment produced about 2 fold amount of MA at $ 60^{\circ}C $ compared with $ 80^{\circ}C $. In comparison with PBS, OBS produced much amount of MA and a bit different from non-irradiated treatment but did not show no tendency. As irradiation levels and heating temperature increased, the amount of cholesterol oxides products was increased and also pan-heating method, direct heating method, significantly increased the degree of oxidation compared with oven-heating method, indirect heating method (p < 0.05).

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Analytical Characteristics of Electron Spin Resonance for Identifying Irradiated Ramen Soup with Radiation Sources (방사선 조사된 라면수프의 조사선원에 따른 전자스핀공명 분석특성)

  • Ahn, Jae-Jun;Lee, Ju-Woon;Chung, Hyung-Wook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.131-135
    • /
    • 2009
  • The identification characteristics of irradiated commercial Ramen soup were investigated depending on radiation sources and doses by electron spin resonance (ESR) spectroscopy. Two commercial powder soups (RS-1, RS-2) were irradiated at 0 to 20 kGy under ambient conditions by both a Co-60 gamma irradiator and an electron beam (EB) accelerator, respectively. Crystalline sugar-induced multi-component signals with g-values of 2.010/2.011, 2.006, 2.002 and 1.999 were detected in the irradiated Ramen soup (RS-1, RS-2), whereas $Mn^{2+}$ signals were observed in non-irradiated samples, thereby distinguishing each other. Under the same analytical conditions, the intensity of ESR signals was higher in EB-irradiated samples than the gamma-irradiated ones. Determination coefficients ($R^2$) between irradiation doses and corresponding ESR responses were above 0.9665 in all the samples, and the magnetic field of specified g-value remained constant. The predominant ESR signals of $g_2$ (2.010-2.011) and $g_3$ (2.002) increased with corresponding doses of irradiation ($R^2$= 0.9750-0.9981).

Nanocrystalline Si formation inside SiNx nanostructures usingionized N2 gas bombardment (이온화 N2 가스 입사를 이용한 SiNx 나노구조 내부의 Si 나노결정 형성)

  • Jung, Min-Cherl;Park, Young-Ju;Shin, Hyun-Joon;Byun, Jun-Seok;Yoon, Jae-Jin;Park, Yong-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.474-478
    • /
    • 2007
  • Nanostructures of $SiN_x$ were made by bombardment of ionized $N_2$ on Si surface and subsequent annealing. Atomic force micrograph showed the density of $SiN_x$ nanostructures was $3\times10^{10}/cm^2$. Their lateral size and height were 40$\sim$60 nm and 15 nm, respectively. The chemical state of the nanostructure was measured using X-ray photoelectron spectroscopy, which changed from $SiN_x$ to $Si_3N_4\;+\;SiN_x$ as the bombarding ionized gas current increases. Upon annealing, transmission electron micrograph showed a clear evidence for crystalline Si phase formation inside the $SiN_x$ nanostructures. Photoluminescence peak observed at around 400nm was thought to be originated from the interface states between the nanocrystalline Si and surrounding $SiN_x$ nanostructures.

Synthesis of ion Exchange Fiber Containing Amidoxime and Phosphoric Acid Groups and Its Uranium Adsorption Properties (아미드옥심기와 인산기가 함유된 이온 교환 섬유의 합성 및 우라늄 흡착 특성)

  • 황택성;박진원
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.242-248
    • /
    • 2003
  • PP-g-(AN/Sty) was synthesized by grafting with acrylonitrile (AN) and styrene (Sty) onto PP staple fiber using an electron beam accelerator and followed by amidoximination and phosphorylation. Mole fraction of AN in the graft chain increased with the increase of the AN content in the monomer mixture. The highest AN grafting yield of 45% was obtained at a monomer ratio of 40 vol% AN/60 vol% Sty. Mole fraction of AN in the graft chain decreased with the increase of methanol amount used its solvent. As reaction temperature increased, the grafting yield of copolymer increased and reached equilibrium at 50$^{\circ}C$. Amount of amidoxime group in fibrous ion exchanger was increased as increasing amount of hydroxylamine, and the maximum content of amidoxime group was observed at 5.8 mmol/g with the 9 wt% hydroxylamine concentration. Content of phosphorous group in fibrous ion exchanger increased up to 0.5 N phosphoric acid concentration, and then leveled off. The adsorption ability of the copolymer for uranyl ion by the chelating adsorbents was in the following order : bifunctional PP-g-(AN/sty) > amidoximated PP-g-(AN/Sty) > phosphorylated PP-g-(AN/Sty).

임플란트용 $TiO_2$ 나노튜브의 전자빔 조사효과

  • Yun, Seong-Uk;O, Seung-Han;Sim, In-Bo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.239.2-239.2
    • /
    • 2011
  • 치과재료의 개발은 치과 치료 기술에 있어서 가장 중요한 요소이며, 현재 일반화되고 있는 치과 치료 기술 중 하나가 임플란트 시술이다. 임플란트의 기술 개발은 주로 임플란트 나사의 표면개질을 통한 기능개선에 초점을 ��추어 진행되어지고 있다. 본 연구에서는 Ti 임플란트 표면상에 양극산화법을 적용하여 다양한 지름 및 기공 크기를 갖는 $TiO_2$ 나노튜브를 제조하여 전자빔 조사를 통한 표면개질시 그 특성에 관한 연구를 수행하였다. 특히 전자빔 조사가 Ti/$TiO_2$ 나노튜브 표면상에 존재 가능한 조골세포의 성장 특성에 미치는 영향을 연구하였다. 양극산화법을 이용한 Ti/$TiO_2$ 나노튜브는 전해질로서 HF와 $NH_4F$를 사용하였으며, 20-80 V의 인가 전압하에서 내경 약 80 nm, 외경 약 124 nm 및 길이 약 280 nm-14 ${\mu}m$의 비교적 균질한 지름 및 분포를 갖는 Ti/$TiO_2$ 나노튜브를 제조하였다. 전자빔 조사는 EB-Tech (대전, 한국)의 electron-beam accelerator(Model ELV-4)를 이용하였으며, 1.0 MeV의 빔 에너지로 총 흡수선량이 50 kGy, 500 kGy 및 5,000 kGy로 조사하였다. 전자빔을 조사하기 전 후 Ti/$TiO_2$ 나노튜브 표면상에 조골세포주(Osteoblast cell)의 배양시간의 변화에 따른 효과를 연구한 결과 배양 전 후 전자빔 조사선량의 증가에 따라 조골세포의 흡착률이 증가함을 확인할 수 있었다. 특히 HF전해질을 이용한 $TiO_2$ 나노튜브의 경우 5,000 kGy 조사선량의 전자빔을 조사한 후 조골세포 흡착률이 약 160% 증가하는 결과를 얻을 수 있었다. 전자빔 조사 전 후 조골세포 흡착률의 변화원인은 전자빔 조사 유무에 따른 $Ti^{3+}$$Ti^{4+}$의 변화에 기인함을 규명하였다. 이러한 결과는 향후 임플란트용 Ti/$TiO_2$ 나노튜브의 표면 개질시 전자빔의 유용성을 제시한다고 할 수 있다.

  • PDF

Comparison analysis of superconducting solenoid magnet systems for ECR ion source based on the evolution strategy optimization

  • Wei, Shaoqing;Lee, Sangjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • Electron cyclotron resonance (ECR) ion source is an essential component of heavy-ion accelerator. For a given design, the intensities of the highly charged ion beams extracted from the source can be increased by enlarging the physical volume of ECR zone [1]. Several models for ECR ion source were and will be constructed depending on their operating conditions [2-4]. In this paper three simulation models with 3, 4 and 6 solenoid system were built, but it's not considered anything else except the number of coils. Two groups of optimization analysis are presented, and the evolution strategy (ES) is adopted as an optimization tool which is a technique based on the ideas of mutation, adaptation and annealing [5]. In this research, the volume of ECR zone was calculated approximately, and optimized designs for ECR solenoid magnet system were presented. Firstly it is better to make the volume of ECR zone large to increase the intensity of ion beam under the specific confinement field conditions. At the same time the total volume of superconducting solenoids must be decreased to save material. By considering the volume of ECR zone and the total length of solenoids in each model with different number of coils, the 6 solenoid system represented the highest coil performance. By the way, a certain case, ECR zone volume itself can be essential than the cost. So the maximum ECR zone volume for each solenoid magnet system was calculated respectively with the same size of the plasma chamber and the total magnet space. By comparing the volume of ECR zone, the 6 solenoid system can be also made with the maximum ECR zone volume.

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

Dosimetric characterization and commissioning of a superficial electronic brachytherapy device for skin cancer treatment

  • Park, Han Beom;Kim, Hyun Nam;Lee, Ju Hyuk;Lee, Ik Jae;Choi, Jinhyun;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.937-943
    • /
    • 2018
  • Background: This work presents the performance of a novel electronic brachytherapy (EBT) device and radiotherapy (RT) experiments on both skin cancer cells and animals using the device. Methods and materials: The performance of the EBT device was evaluated by measuring and analyzing the dosimetric characteristics of X-rays generated from the device. The apoptosis of skin cancer cells was analyzed using B16F10 melanoma cancer cells. Animal experiments were performed using C57BL/6 mice. Results: The X-ray characteristics of the EBT device satisfied the accepted tolerance level for RT. The results of the RT experiments on the skin cancer cells show that a significant apoptosis induction occurred after irradiation with 50 kVp X-rays generated from the EBT device. Furthermore, the results of the animal RT experiments demonstrate that the superficial X-rays significantly delay the tumor growth and that the tumor growth delay induced by irradiation with low-energy X-rays was almost the same as that induced by irradiation with a high-energy electron beam. Conclusions: The developed new EBT device has almost the same therapeutic effect on the skin cancer with a conventional linear accelerator. Consequently, the EBT device can be practically used for human skin cancer treatment in the near future.