X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube (X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구)

  • Lee Sang-Joon;Kim Seok;Paik Bu-Geun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

Study on the high precision output of full-bride high-voltage inverter (Full-bridge 고전압 인버터의 출력전압 정밀제어에 관한연구)

  • Son, Y.G.;Kwon, S.J.;Jang, S.D.;Suh, J.H.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.214-216
    • /
    • 2005
  • The PAL (Pohang Accelerator Laboratory) is persuading to construct a SASE-XFEL facility (PAL XFEL) that supplies coherent X-rays. The bright and stable electron beam is essential for the PAL XEL. The electron beams has to have an emittance of 1.0 mm-mrad, a peak current of 3 kA, and a low energy spread of 1.0 MeV. In order to provide reasonably stable SASE output, the RF stability of 0.02% rms is required for both RF phase and amplitude. This is a technologically challenging issue for PAL XFEL. An inverter technology is to be applied to charge the PFN of a new modulator. Therefore, a new inverter system should provide very stable charging performances. This paper presents the development of an ultra stable klystron-modulator with an inverter power supply.

  • PDF

Chemical Mechanisms and Process Parameters of Flue Gas Cleaning by Electron beam (전자빔에 의한 배연가스 정화기술의 화학반응 메카니즘에 대하여)

  • Choe, Gap-Seok;Choe, Yeon-Seok;Kim, Han-Seok
    • 연구논문집
    • /
    • s.23
    • /
    • pp.93-107
    • /
    • 1993
  • The chemistry and performance characteristics of the EBDS process have been introduced, in which experimental results from laboratory, test plant, and pilot plant studies agree very well and can be understood from detailed kinetic models. The parametric dependencies of the NOx and $SO_2$, removal yields on the input conditions have been discussed and formulated quantitatively. The process is best suited for flue gas with high $SO_2$, loadings. The operation conditions, such as dose, ammonia, and water additions, can be adjusted fast upon load changes. The process works waste water free and the major product is a mixture of ammonium nitrate and sulfate that can be used as fertilizer. The up-date results show that the EBDS technology is safe and competitive with other already well-established technologies. Due to these interesting features, the electron beam process has gained much international recognition. Demonstration units of 100MW have been proposed in the United States and Japan. Further pilot plants are under construction in Poland and China, countries that make abundant use of highsulfur coal. Additional research activities are under way to further improve the energy efficiency of process, and accelerator prices have been decreasing during the past 10 years. So the EBDS process has a good chance to start a new generation of emission-control technology.

  • PDF

AN EXPERIMENTAL STUDY OF THE EFFECTS OF ION BEAM HIKING ON CERAMO-METAL BONDING (이온선 혼합법이 도재와 금속의 결합에 미치는 영향에 관한 실험적 연구)

  • Hong, Joon-Pow;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.245-265
    • /
    • 1991
  • The purpose of this study was to observe the changes of the elemental transmission and bond strength between the metal and porcelain according to various kinds of ion beam mixing method. ion beam mixing of $meta1/SiO_2$ (silica), $meta1/Al_2O_3$(alumina) interfaces causes reactions when the $Ar^+$ was implanted into bilayer thin films using a 100KeV accelerator which was designed and constructed for this study. A vacuum evaporator used in the $10^{-5}-10^{-6}$ Torr vacuum states for the evaporation. For this study, three kinds of porcelain metal selected, -precious, semiprecious, and non-precious. Silica and alumina were deposited to the metal by the vacuum evaporator, separately. One group was treated by two kinds of dose of the ion beam mixing $(1\times10^{16}ions/cm^2,\;5\times10^{15}ions/cm^2)$, and the other group was not mixed, and analyzed the effects of ion beam mixing. The analyses of bond strength, elemental transmissions were performed by the electron spectroscopy of chemical analysis (ESCA), light and scanning electron microscope, scratch test, and micro Vickers hardness tests. The finding led to the following conclusions. 1. In the scanning electron and light microscopic views, ion beam mixed specimens showed the ion beam mixed indentation. 2. In the micro Vickers hardness and scratch tests, ion beam mixed specimens showed higher strength than that of non mixed specimens, however, nonprecious metal showed a little change in the bond strength between mixed and non mixed specimens. 3. In the scratch test, ion beam mixed specimens showed higher shear strength than that of non treated specimens at the precious and semiprecious groups. 4. In the ESCA analysis, Au-O and Au-Si compounds were formed and transmission of the Au peak was found ion beam mixed $SiO_2/Au$ specimen, simultaneously, in the higher and lower bonded areas, and ion beam mixed $SiO_2/Ni-Cr$ specimen, oxygen, that was transmitted from $SiO_2\;to\;SiO_2/Ni-Cr$ interface combined with 12% of Ni at the interface.

  • PDF

Determination of Initial Beam Parameters of Varian 2100 CD Linac for Various Therapeutic Electrons Using PRIMO

  • Maskani, Reza;Tahmasebibirgani, Mohammad Javad;Hoseini-Ghahfarokhi, Mojtaba;Fatahiasl, Jafar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7795-7801
    • /
    • 2015
  • The aim of the present research was to establish primary characteristics of electron beams for a Varian 2100C/D linear accelerator with recently developed PRIMO Monte Carlo software and to verify relations between electron energy and dose distribution. To maintain conformity of simulated and measured dose curves within 1%/1mm, mean energy, Full Width at Half Maximum (FWHM) of energy and focal spot FWHM of initial beam were changed iteratively. Mean and most probable energies were extracted from validated phase spaces and compared with related empirical equation results. To explain the importance of correct estimation of primary energy on a clinical case, computed tomography images of a thorax phantom were imported in PRIMO. Dose distributions and dose volume histogram (DVH) curves were compared between validated and artificial cases with overestimated energy. Initial mean energies were obtained of 6.68, 9.73, 13.2 and 16.4 MeV for 6, 9, 12 and 15 nominal energies, respectively. Energy FWHM reduced with increase in energy. Three mm focal spot FWHM for 9 MeV and 4 mm for other energies made proper matches of simulated and measured profiles. In addition, the maximum difference of calculated mean electrons energy at the phantom surface with empirical equation was 2.2 percent. Finally, clear differences in DVH curves of validated and artificial energy were observed as heterogeneity indexes were 0.15 for 7.21 MeV and 0.25 for 6.68 MeV. The Monte Carlo model presented in PRIMO for Varian 2100 CD was precisely validated. IAEA polynomial equations estimated mean energy more accurately than a known linear one. Small displacement of R50 changed DVH curves and homogeneity indexes. PRIMO is a user-friendly software which has suitable capabilities to calculate dose distribution in water phantoms or computerized tomographic volumes accurately.

Comparative Study of Sterilization by Gamma-ray and Electron-Beam (감마선, 전자선에 의한 멸균 비교분석)

  • Jeong, Kyeonghwan;Park, Changhee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.537-543
    • /
    • 2020
  • The elderly population in the modern society is growing rapidly due to advance medical technology and minimally invasive surgery. Therefore, as the tendency to use medical device is increasing, pathogenic infection is a concern. Therefore, the first aim of modern medicine is infection prevention in medical place. Recently, patient implants are increasing using 3D printing. Hydroxyapatite is used as a representative material. And, there haven't had currently absorbed dose standard for sterilization of hydroxyapatite discs. Escherichia coli and Streptococcus mutans contaminated on the surface of hydroxyapatite discs were irradiated at each absorbed dose of 0, 0.5, 1.0, 3.0, 5.0 kGy using Gamma-ray of cobalt and Electron-beam of linear accelerator. Then, the number of bacteria was measured in the sample by the decimal dilution method. After sterilization, a non-parametric testing method was performed to compare the survival of Escherichia coli and Streptococcus mutans. As a result, Escherichia coli was sterilized at 1 kGy or more and Streptococcus mutans at 3 kGy or more on absorbed dose. It is considered possible to perform sterilization at a lower value than the recommended absorbed dose of radiation sterilization.

Characterization of Epoxy Resin Containing Nano Clay Prepared by Electron Beam (전자선에 의해 제조된 나노 clay 함유 에폭시 수지의 특성)

  • Park, Jong-Seok;Lee, Seung-Jun;Lim, Youn-Mook;Jeong, Sung-In;Gwon, Hui-Jeong;Shin, Young-Min;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • Epoxy resin is widely used as aerospace, automobile, construction and electronics due to their good mechanical and electrical properties and environmental advantages. However, the inherent flammability of epoxy resin has limited its application in some field where good flame retardancy is required. Nano clay can enhance the properties of polymers such as flames retardancy and thermal stability. In this study, we have investigated the nanoclay filled epoxy composite, which has good flame retardancy while maintaining high mechanical properties. The cured epoxy resins were obtained using an electron beam curing process. The nano clays were dispersed in epoxy acrylate solution and mechanically stirred. The prepared mixtures were irradiated using an electron beam accelerator. The composites were characterized by gel content and thermal/mechanical properties. Moreover, the flammability of the composite was evaluated by limited oxygen index (LOI). The flame retardancy of nano clay filled epoxy composite was evidently improved.

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET) (전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정)

  • Hwang, Ui-Jung;Rah, Jeong-Eun;Jeong, Ho-Jin;Ahn, Sung-Hwan;Kim, Dong-Wook;Lee, Sang-Yeob;Lim, Young-Gyung;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Park, Sung-Young;Pyo, Hong-Ryull;Chung, Weon-Kuu
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.60-69
    • /
    • 2010
  • For treatment of Total Skin Electron beam Therapy (TSET), measurement of dose at various conditions is need on the contrary to usual radiotherapy. When treating TSET with modified Stanford technique based on linear accelerator, the energy of treatment electron beam, the spatial dose distribution and the actual doses deposited on the surface of the patient were measured by using EBT2. The measured energy of the electron beam was agreed with the value that measured by ionization chamber, and the spatial dose distribution at the patient position and the doses at several point on the patient's skin could be easily measured by EBT2 film. The dose on the patient that was measured by EBT2 film showed good agreement with the data measured simultaneously by TLD. With the results of this study, it was proven that the EBT2 film can be one of the useful dosimeter for TSET.

Effects of Electron-Beam Irradiation on the Physico-chemical Properties of Hanwoo Meat (전자선 조사가 포장방법을 달리한 한우육의 이화학적 특성에 미치는 영향)

  • Park, Tae-Seon;Park, Gu-Bu;Oh, Seong-Hyeon;Lee, Jeong-Il;Sin, Taek-Sun
    • Journal of Life Science
    • /
    • v.17 no.2 s.82
    • /
    • pp.260-265
    • /
    • 2007
  • This study was carried out to investigate the effect of Electron Beam irradiation on physico-chemical characteristics of Hanwoo meat. A total of sir beef carcasses $(280{\sim}300\;kg)$ that were quality grade $1^+$(marbling score No. 7, meat color No. 4, maturity No. 1, texture No. 1) was purchased at the commercial slaughter house. The carcasses were transported and washed using high pressure water, and pasteurized with 50% ethyl alcohol in the laboratory. After the carcasses were deboned and trimmed, loin and round were taken out to make steak (1.5 cm thickness) or patty respectively. Samples were wrap or vacuum packaged and irradiated with 0, 3, 4.5, 6 and 7.5 kGy using electron-beam accelerator. Irradiated samples were used to measure pH, moisture, crude protein, crude fat, and meat color. There was no significant (p>0.05) difference in pH between vacuum packaged (VP) and wrap packaged (WP) treatment, and the pH was not changed by electron-beam irradiation levels. Both control and irradiated treatments of steak showed higher tendency in moisture content. In crude protein content, control was higher than irradiated treatment in steak, but there were no difference in patty. Lightness ($L^{\ast}$) of meat color has no difference between irradiated and non-irradiated treatment (p>0.05). The value of redness and Yellowness of meat was dropped by increasing irradiation (p<0.05), but there was no difference between control and 3 kGy treatment (p<0.05).