• Title/Summary/Keyword: Electron Configuration

Search Result 165, Processing Time 0.039 seconds

Construction of Anaglyphic Stereo Pair Image using Adobe $Photoshop^{(R)}$ Program (어도비포토샵 프로그램을 이용한 anaglyphic 입체영상 제작법)

  • Kim, Jee-Woong;Lee, Se-Jeong;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.143-146
    • /
    • 2007
  • The objects of the nature have three dimensional (3-D) parameters. The 3-D profiles are embedded on the photographs and microscopic images. To understand 3-D configuration, stereo pair image with thick section is frequently employed. The perception of 3-D images is possible with the aid of stereoscopic glasses, although the expert can perceive 3-D images without the glasses. Anaglyphic stereo images are constructed by various softwares from commercial and freeware. Here we would like to present an easy anaglyphs construction method with Adobe $Photoshop^{(R)}$ based on tilting paired images from high voltage electron microscope. The anaglyphic stereo images constructed revealed the same 3-D perception with conventional stereoscopy. We could zoom in/out the anaglyph image digitally to investigate the detail configuration by real time. This method is expected to contribute to understanding complex structures 3 dimensionally.

EFFECTS OF VARIOUS NSAIDS ON PROSTAGLANDIN SYNTHESIS AND CELLULAR CONFIGURATION OF HUMAN PERIODONTAL LIGAMENT CELLS (다양한 NSAID가 인간 치주인대세포의 prostaglandin 합성 및 세포 형태에 미치는 효과에 대한 연구)

  • Kim, Hyeok-Soo;Shim, Hae-Young;Chae, Chang-Hoon;Chang, Young-Il;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.455-463
    • /
    • 2007
  • The present study was designed to evaluate effects of the commonly used NSAIDs(acetaminophen, aspirin, and ibuprofen) on human periodontal ligament cells. Human periodontal ligament cells were grown from a cell line provided by Kyungpook National University. Effects of NSAIDs on the proliferation of human periodontal ligament cells were assessed using MTT assays. And then $PGE_2$ concentrations were determined by ELISA and the changes of cellular configuration were found by electron micrograph. The results were as follows; 1. The MTT assay demonstrated that the commonly used NSAIDs(acetaminophen, aspirin, and ibuprofen) had not significant cytotoxic effect on human periodontal ligament cells. 2. NSAIDs inhibited the $PGE_2$ synthesis of human periodontal ligament cells compared with the control group. These inhibitory effects had no significant differences with NSAID type and concentration. 3. Electron micrographs of human periodontal ligament cells treated with NSAIDs showed more narrow and irregular shape.

A Fundamental Study on the Electron Behavior and Optimum Condition for the Formation of a Neutral Loop Discharge Plasma (Neutral Loop Discharge 플라즈마의 전자거동과 최적조건에 관한 기초적 연구)

  • Sung, Youl-Moon;Kim, Jong-Kyung;Park, Chung-Hoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.281-287
    • /
    • 2001
  • In order to obtain guidelines for design and operation of a new plasma source by a magnetic neutral loop discharge(NLD), the electron behavior was studied experimentally and numerically. Experimentally, the magnetic field gradient was changed over a wide range, and it was found that there existed an optimum value for efficient plasma production. Analyses of the electron behavior were performed using a model that included effects of a three dimensional electromagnetic field configuration considering the spatial decay of the electric field, and the limitation to the motion of electron caused by the existence of walls and thus electron loss at wall surfaces. These three dimensional factors were found to explain the existence of the optimum magnetic field gradient. It was shown that the L dependence of the plasma production efficiency was firstly decided by the finite decay length of the electric field strength, which was further modified by electron elastic collisions with neutral atoms which drove the electron to walls. The latter effect tends to reduce the optimum value of L.

  • PDF

A Two-dimensional Steady State Simulation Study on the Radio Frequency Inductively Coupled Argon Plasma

  • Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.5
    • /
    • pp.246-252
    • /
    • 2002
  • Two-dimensional steady state simulations of planar type radio frequency inductively coupled plasma (RFICP) have been performed. The characteristics of RFICP were investigated in terms of power transfer efficiency, equivalent circuit analysis, spatial distribution of plasma density and electron temperature. Plasma density and electron temperature were determined from the equations of ambipolar diffusion and energy conservation. Joule heating, ionization, excitation and elastic collision loss were included as the source terms of the electron energy equation. The electromagnetic field was calculated from the vector potential formulation of ampere's law. The peak electron temperature decreases from about 4eV to 2eV as pressure increases from 5 mTorr to 100 mTorr. The peak density increases with increasing pressure. Electron temperatures at the center of the chamber are almost independent of input power and electron densities linearly increase with power level. The results agree well with theoretical analysis and experimental results. A single turn, edge feeding antenna configuration shows better density uniformity than a four-turn antenna system at relatively low pressure conditions. The thickness of the dielectric window should be minimized to reduce power loss. The equivalent resistance of the system increases with both power and pressure, which reflects the improvement of power transfer efficiency.

Analyses on the Degree of Learning Achievement by Students and on Differences of Explaining in High School Chemistry-II Textbooks for the Atomic Models and Electron Configurations (원자모형과 전자배치 단원에 대한 고등학교 학생들의 학습 성취도 및 화학 II 교과서의 설명방식의 차이점에 대한 분석)

  • Chang Kon Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.3
    • /
    • pp.273-282
    • /
    • 2003
  • A questionnaire on "atomic models and electron configuration" was performed on 34 of 11th grade and 38 of 12th grade students who took the Chemistry-II course in order to examine the degree of learning achievement. Also eight Chemistry-II textbooks published in the 6th curriculum were analyzed for the similarities and differences in dealing with this topic and possible improvements were discussed in conjunction with the questionnaire. The results of this questionnaire showed that the degree of learning achievement on the topics between two different classes were not much different in general, although a little difference was found. This indicates that the topics have been taught in early 11th grade but subsequent supplemental teaching has not been performed. To study on the topics of "atomic models and electron configuration" effectively and systematically, knowledge on the basic spectroscopy and quantum mechanics should be preceeded. However this could be practically difficult under the current high school curriculum. Therefore It would be necessary to describe the basic concepts for the quantum mechanics and spectroscopy schematically in the "Reference Materials" section of the textbook, even if it is not very long. On the other hand, the Chemistry-II textbooks analyzed in this work reveal, in general, to have the similar organization and explanation modes. However it has been analyzed that a connection between the Bohr and electron-cloud atomic models might be insufficient or position of electrons might be possible to be misunderstood by students in some textbooks.

Study of the Valence and Rydberg States of a Lithium Dimer by the Multi-reference Configuration-interaction Method

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1422-1432
    • /
    • 2014
  • Convergent all-electron multi-reference configuration-interaction (MRCI) calculations are performed for a lithium dimer with Kaufmann's Rydberg basis functions. A comparison of the results of these calculations with those of the effective core potential/core polarization potential (ECP/CPP) method and experimental data reveals the deficiency of the all-electron ab initio method. The deficiency is related to the mere 51.9% attainment of electron correlation for the ground state. The percent attainment of electron correlation for the first excited state is slightly better than that for the ground state, preventing us from obtaining better agreements with experimental data by means of increasing the size of basis sets. The Kaufmann basis functions are then used with the ECP/CPP method to obtain the accurate convergent potential energy curves for the $^1\prod_u$ states correlated to Li(2p) + Li(2p) and Li(2s) + Li(n = 2, 3, 4). Quantum defect curves (QDCs) calculated for both the $X^2\sum_g$ and 1 $^2\prod_u$ states of the $Li{_2}^+$ ion and the Lu-Fano plot reveal a strong series-series interaction between the two $2snp{\pi}$ and $2pnp{\pi}$ Rydberg series. The QDCs are then used to resolve assignment problems in the literature. The reassignments, performed by Jedrzejewski-Szemek et al., of the dissociation product of the D $^1\prod$ state from (2s+3d) to (2s+3p) and that of the 6 $^1\prod_u$ from (2s+4d) to (2s+4p) are found to be incorrect. It may be more natural to assign their $2snp{\pi}$ Rydberg series as a $2snd{\pi}$ series. The state, assigned as 5p $^1\prod_u$ by Ross et al. and 4d $^1\prod$ by Jedrzejewski-Szemek et al., is assigned as the 7 $^1\prod_u$ state, correlated to the Li(2s) + Li(4f) limit.

Role of Magnetic Field Configuration in a Performance of Extended Magnetron Sputtering System with a Cylindrical Cathode

  • Chun, Hui-Gon;Sochugov, Nikolay S.;You, Yong-Zoo;Soloviv, Andrew A.;Zakharov, Alexander N,
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.3
    • /
    • pp.19-23
    • /
    • 2003
  • Extended unbalanced magnetron sputtering system based on the cylindrical magnetron with a rotating cathode was developed. The unbalanced configuration of magnetic field was realized by means of additional lines of permanent magnets, placed along both sides of a 89 mm outer diameter and 600 mm long cylindrical cathode. The performance of the unbalanced magnetron was assessed in terms of the ion current density and the ion-to-atom ratio incident at the substrate. Furthermore, the paper presents the comparison of the internal plasma parameters, such as the electron temperature, electron density, plasma and floating potentials, measured by a Langmuir probe in various positions from the cathode, for conventional and unbalanced constructions of the cylindrical magnetron. The plasma density and ion current density are about 3-5 times higher than those of conventional one, in the unbalanced magnetron in a 0.24 Pa Ar atmosphere with a DC cathode power of 3 kW.

  • PDF

A Study on the Optimum Design of the Condenser Lens of a Compact Electrostatic-Type SEM (전기장형 소형 주사전자현미경의 집속렌즈의 최적 설계에 대한 연구)

  • Kim, Ki-Hwan;Jang, Dong-Young;Park, Man-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.270-277
    • /
    • 2015
  • In this paper, we describe the production of a specific electrostatic-type scanning electron microscope based on miniaturization for application in other types of vacuum equipment. The initial configuration of the SEM starts with a minimal configuration that allows people to view sample images. After improving the stability of the SEM operation and resolution, we conducted experiments on identifying the characteristics and development of an einzel-type condenser lens with reference to the demagnification lens system of an SEM. The experiments were conducted at an acceleration voltage of 5 kV and we found the shape of the lens to be more reliable than a conventional lens. The lens was then added to improve the resolution in the nanometer region. The current measured on the sample was approximately 40 pA and its magnification was 4,000 times.