• 제목/요약/키워드: Electromagnetic vibration

검색결과 405건 처리시간 0.028초

전자기력을 이용한 2 자유도 스캐닝 미러 설계 (Design of 2-DoF Scanning Mirror using Electromagnetic force)

  • 신부현;김영진;오동호;이정우;최현호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2014
  • This work proposes a two-dimensional (2-D) laser scanning mirror actuator with a simple structure composed of one magnet and four coils. The mirror-actuating device generates 2-D scanning motions about two orthogonal axes by combining electromagnetic actuators of the conventional moving-magnet types. The magnet is attached to back side of the mirror placed inside of the moving frame. The four coils is placed on the base frame in a cross shape. We implement a finite element analysis to calculate magnetic flux in the electromagnetic system with the overall size of $20mm(W){\times}20mm(D){\times}13mm(H)$ for the mirror size of $8mm{\times}8mm$. The each moving-magnet type electromagnetic actuator has the motor constant 3.41 mNm/A and the restoring constant 1.75 mNm/rad and the resonance frequency of 58 Hz and the bandwidth of 80 Hz. The proposed compact and simple 2-D scanning mirror predicted advantages of large 2-D angular deflections, wide frequency bandwidth and low manufacturing cost.

  • PDF

변환행렬법을 이용한 케이블 권선형 배전용 변압기 귄선의 진동모드 해석 (A Vibration Mode Analysis of Cable-type Winding for Distribution Power Transformer by using Transfer Matrix Method)

  • 신판석;정현구;윤구영
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.85-91
    • /
    • 2009
  • 본 논문에서는 배전계통에 사용되는 케이블 권선형 변압기에 전력계통에서 발생되는 서지나 고장전류에 의해서 변압기의 고압측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하고, 기계진동방정식을 이용하여 케이블형 권선의 고유진동주파수를 분석하였다. 변압기모델로서 1(MVA), 22,900/220([V]) 단상 외철형 Cable형을 선정하여, 권선의 각방향의 전자력을 분석하고, 고유진동 mode를 Transfer Matrix Method를 이용하여 계산하고 상용 프로그램(ANSYS)을 이용하여 분석한 결과와 비교하였다. 진동모드의 분석한 결과 제시한 수치해석 방법은 공학적인 오차범위 안에서 충분히 수용할 정도의 정확도를 보여주었다. 변압기 권선의 전자력과 진동모드 분석결과는 변압기의 절연설계 및 단락기계력에 의한 절연 구조 설계를 위한 유용한 자료로 활용될 수 있다.

탄성지지된 가동코일형 능동마운트의 성능 분석 (A Performance Analysis of Active Mount with Moving-Coil type Electromagnetic Actuator Installed on the Elastic Foundation)

  • 정우진;배수룡;전재진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.227-231
    • /
    • 2014
  • Underwater radiated noise is one of the vital factors in underwater weapon systems like submarine. A passive elastic mount is an effective reduction method for the vibration from a ship-board machinery transmitted to the hull which is radiated as noise outside the hull. A passive elastic mount shows the limitation on the vibration reduction and needs multi stage mounting system including double stage one to meet the required underwater radiated noise criteria. It is necessary for the multi stage mounting system to consider the large displacement in the underwater shock explosion. So it is difficult to apply the multi stage mounting system in submarine because of space limitation. Also recent navy sonar system are trying to have the capability to detect the ship-borne acoustic signals in the low frequency range. An alternative to the passive mount is an active mount with moving-coil type electromagnetic actuator based on a conventional rubber mount in the low frequency range. In the previous paper, 4 active mounts with moving-coil type electromagnetic actuator based on the rubber mount were installed on the hard floor of the facility, which means no consideration on the elastic foundation effect for the control of the active mounts was taken into account. In this study, an experimental performance analysis on the active mount was carried out using 4 active mounts installed on the cylindrical structure to investigate the elastic foundation effect.

  • PDF