• 제목/요약/키워드: Electromagnetic pulse

검색결과 423건 처리시간 0.019초

두부하위$(-6^{\circ})$로의 체위변동이 말초혈류에 미치는 영향 (Effects of Head-down Tilt $(-6^{\circ})$ on Peripheral Blood Flow in Dogs)

  • 채의업;양선영;배재훈;송대규
    • The Korean Journal of Physiology
    • /
    • 제24권1호
    • /
    • pp.51-65
    • /
    • 1990
  • The purpose of the present study was to examine the hemodynamic responses, especially in arterial and skin blood flows, in conjunction with the changes of plasma catecholamine levels as an indirect marker of adrenergic tone during the early stage of head-down tilt (HDT), and to evaluate the early physiological regulatory mechanism in simulated weightlessness. Ten mongrel dogs, weighing8\;{\sim}\;14\;kg, were intravenously anesthetized with nembutal, and postural changes were performed by using the tilting table. The postural changes were performed in the following order: supine, prone, HDT $(-6^{\circ}C)$ and lastly recovery prone position. The duration of each position was 30 minutes. The measurements were made before, during and after each postural change. The arterial blood flow $({\.{Q}})$ at the left common carotid and right brachial arteries was measured by the electromagnetic flowmeter. Blood pressure (BP) was directly measured by pressure transducer in the left brachial artery. To evaluate the peripheral blood flow, skin blood flow $({\.{Q}})$ was calculated by the percent changes of photoelectric pulse amplitude on the forepaw, and skin temperature was recorded. The peripheral vascular resistance (PR) was calculated by dividing respective mean BP values by ${\.{Q}}$ of both sides of common carotid and brachial arteries. Heart rate (HR), respiratory rate (f) and PH, $Po_{2},\;Pco_{2}$ and hematocrit of arterial and venous blood were also measured. The concentration of plasma epinephrine and norepinephrine was measured by radioenzymatic method. The results are summarized as follows: Tilting to head-down position from prone position, HR was initially increased (p<0.05) and BP was not significantly changed. While ${\.{Q}}$ of the common carotid artery was decreased (p<0.05) and PR through the head was increased, ${\.{Q}}$ of the brachial artery was increased (p<0.05) and PR through forelimbs was decreased. ${\.{Q}}$ of the forepaw was initially increased (p<0.05) and then slightly decreased, on the whole revealing an increasing trend. Plasma norepinephrine was slightly decreased and the epinephrine was slightly increased. f was increased and arterial pH was increased (p<0.05). In conclusion, the central blood pooling during HDT shows an increased HR via Bainbridge reflex and an increased ${\.{Q}}$ of the forepaw and brachial ${\.{Q}}$, due to decreased PR which may be originated from the depressor reflex of cardiopulmonary baroreceptors. It is suggested that the blood flow to the brain was adequately regulated throughout HDT $(-6^{\circ}C)$ in spite of central blood pooling. And it is apparent that the changes of plasma norepinephrine level are inversely proportional to those of ${\.{Q}}$ of the forepaw, and the changes of epinephrine level are paralleled with those of the brachial ${\.{Q}}$.

  • PDF

배관결함 검출을 위한 EMAT 시스템 개발 (Development of an EMAT System for Detecting flaws in Pipeline)

  • 안봉영;김영주;김영길;이승석
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.15-21
    • /
    • 2004
  • EMAT(electromagnetic-acoustic transducer)는 비접촉식 초음파 탐촉자이므로 초음파의 송수신을 위하여 접촉매질이 필요하지 않기 때문에 탐촉자를 시험 대상체의 표면을 따라 움직이면서 결함 검출이 가능하며, 코일의 설계와 배열에 따라 표면파와 판파 등 원하는 모드의 유도초음파를 손쉽게 송수신할 수 있기 때문에 두께가 얇은 배관의 탐상에 알맞는 초음파 탐촉자이다. 본 논문에서는 표면초음파 발생을 위한 EMAT와 $A_1$ 모드의 판파, $S_1$ 모드의 판파를 선택적으로 발생시키기 위한 EMAT를 설계 제작하였다. 1.5MHz의 표면초음파는 분산이 없어서 신호 왜곡 없이 높은 신호 대 잡음비로 배관을 진햄함을 보였다. 반면에 800kHz의 $S_1$ 모드의 판파와 940 KHz의 A1 모드의 판파는 분산 특성이 있어서 배관을 따라 진행하면서 신호 왜곡이 생김을 확인할 수 있었으며, EMAT에 공급하는 펄스의 폭을 넓히면 판파의 모드 선택성이 향상되었다. 내경 256mm, 두께 5.5mm인 강관에 가공된 인공결함에 대한 각 모드의 결함 검출능을 서로 비교하였다.

국방 EMP 방호능력의 효율적 개선을 위한 방안 연구 (A Study for the Efficient Improvement Measures of Military EMP Protection Ability)

  • 정승훈;안재춘;황영규;정현주;신용태
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제7권1호
    • /
    • pp.219-227
    • /
    • 2017
  • 현재 군 지휘정보체계는 반도체칩이 장착된 전자기기의 활용도가 높으며, 최신 정보통신기술 발전에 따라 그 비중은 더욱 증가할 것으로 예상된다. 전기를 사용하는 전자기기의 경우 고출력 전기신호에 대한 일정한 내성을 보유하고 있다. 이러한 전자기기 내성을 기준화 한 것이 EMC 규격이다. 한편 원자력 연구원에서는 서울 상공 100km지점에서 10kt급의 핵폭발이 발생할 경우 반경 170km 지역까지 고출력전자기파가 발생하여 해당지역 대부분 전자장비에 피해가 예상된다는 시뮬레이션 결과를 발표한 바 있다. 이러한 경우 발생하는 영향을 방호하기 위한 기준은 EMP 방호 규격으로 정의된다. 대부분의 상용 전자기기의 경우 EMC 기준은 충족하지만 EMP 기준을 충족하는지의 여부를 확인할 수가 없다. EMP 방호기준 충족여부를 확인하기 위한 장비와 절차가 쉽지 않고 비용적인 측면이 있기 때문이다. 보통 부득이한 경우를 제외하고는 EMP 방호기준 충족여부에 대해서는 검증하지 않는 실정이다. 이점을 고려하여 본 연구에서는 EMC-EMP 상관관계 분석을 통하여 일반 전자기기의 EMP 방호능력에 대해서 확인하고 이를 바탕으로 EMP 방호능력 향상방안을 확인하였다.