• 제목/요약/키워드: Electromagnetic pressure

검색결과 208건 처리시간 0.026초

유도결합형 플라즈마에서 압력에 따른 Ar Gas의 특성분석 (Ar Gas properties of Inductively Coupled Plasma for Input Power)

  • 조주웅;이영환;허인성;김광수;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1704-1706
    • /
    • 2003
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56 [MHz] have been measured over a wide range of power at gas pressure ranging from $1{\sim}70$ [mTorr].

  • PDF

Magnetic Hardening of Nano-thick $Sm_2Fe_{17}N_x$ Films Grown by Pulsed Laser Deposition

  • Yang, Choong Jin;Wu, Jianmin
    • Journal of Magnetics
    • /
    • 제5권4호
    • /
    • pp.124-129
    • /
    • 2000
  • $Sm_2Fe_{17}N_x$ film magnets were prepared using a $Sm_2Fe_{17}$ target in a $N_2$ gas atmosphere using a Nd-YAG pulsed laser ablation technique. The effect of nitrogen pressure, deposition temperature, pulse time and film thickness on the structure and magnetic properties of $Sm_2Fe_{17}N_x$ film were studied. Increasing the nitrogen pressure up to 5 atm led to the formation of complete $Sm_2Fe_{17}N_x$ compound. Optimized magnetic properties with the nitrogenation temperature in the range 500-53$0^{\circ}C$ could be obtained by extending the nitrogenation time up to 4 hours. Relatively low coercivities of 400~600 Oe were found in $Sm_2Fe_{17}N_x$films 50~100 m thick, while a $4\piM_s$ of 10$\sim$12 kG could be achieved. In-plane anisotropy, which was the basic goal in this study, was achieved by controlling the nitrogenation parameters.

  • PDF

4차 산업기술을 활용한 원전설비 진동감시기반 예측정비 방안 (Predictive Maintenance Plan based on Vibration Monitoring of Nuclear Power Plants using Industry 4.0)

  • 고도영
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.6-10
    • /
    • 2023
  • Only about 10% of selected equipment in nuclear power plants are monitored by wiring to address failures or problems caused by vibration. The purpose is primarily for preventive maintenance, not for predictive maintenance. This paper shows that vibration monitoring and diagnosis using Industrial 4.0 enables the complete predictive maintenance for all vibrating equipments in nuclear power plants with the convergence of internet of things; wireless technology, big data through periodic collection and artificial intelligence. Predictive maintenance using wireless technology is possible in all areas of nuclear power plants and in all systems, but it should satisfy regulatory guides on electromagnetic interference and cyber security.

EMP 차폐를 위한 도파관 형상과 SE에 따른 유동 특성 평가 (Evaluation of Air Flow Characteristics in accordance with Types of Waveguide-Below-Cutoff (WBC) Arrays and Their Shielding Effectiveness of Electromagnetic Pulse (EMP))

  • 방승기;안혜린;육종관
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.1-8
    • /
    • 2016
  • In this study, we evaluated the flow characteristics of various types of waveguide-below-cutoff (WBC) arrays and their shielding effectiveness (SE) of electromagnetic pulses (EMP) based on computational fluid dynamics (CFD). Three types of waveguides were selected for analysis: (1) grid type, (2) honeycomb type, and (3) multi-layer types (2-ply, 4-ply, 6-ply, and 8-ply). To analyze the air flow characteristics, the flow velocities in the longitudinal center of the WBC and the differential pressures between the WBC array inlet and outlet were evaluated. Consequently, we derive the following conclusions: (1) despite an increase in the inlet velocity, the pressure drop of the 6-ply multi-layer type did not significantly increase as compared to that of other types of waveguides (waveguide thickness of 0.1 mm, SE of 100 dB); (2) the grid and honeycomb type had the fastest flow rate of 17.5 m/s, which is approximately 2.5 m/s faster than that at the inlet (waveguide thickness of 1 mm, module size of 30 mm); and (3) the average pressure drop of the grid type waveguide is the lowest in the overall model, whereas that of the 8-ply is the highest (waveguide thickness of 1 mm, module size of 30 mm, and SE of 80, 100 dB).

격납건물 라이너 플레이트 감육 검사를 위한 전자기 초음파 트랜스듀서의 설계 및 성능 평가 (Design and Test of ElectroMagnetic Acoustic Transducer applicable to Wall-Thinning Inspection of Containment Liner Plates)

  • 한순우;조승현;강토;문성인
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.46-52
    • /
    • 2019
  • This work proposes a noncontact ultrasonic transducer for detecting wall-thinning of containment liner plates of nuclear power plants by measuring their thickness without physical contact. Because the containment liner plate is designed to prevent atmospheric leakage of radioactive substances under severe nuclear accident, its wall-thinning inspection is important for safety of nuclear power plants. Wall-thinning investigation of containment liner plates have been carried out by measuring their thickness with contact-type ultrasonic thickness gauge by inspectors and needs a lot of time and cost. As an alternative, an electromagnetic acoustic transducer measuring precisely thickness of containment liner plates without any physical contact or couplant was suggested in this research. A transducer generating and measuring shear ultrasonic waves in thickness direction was designed and wave field produced by the transducer was analyzed to verify the design. The working performance of the suggested transducer was tested with carbon steel plate specimens with various thicknesses. The test result shows that the proposed transducer can measure thickness of the specimens precisely without any couplant and implies that swift scanning of wall-thinning of containment liner plates will be possible with the proposed transducer.

Improving Sensitivity of SAW-based Pressure Sensor with Metal Ground Shielding over Cavity

  • Lee, Kee-Keun;Hwang, Jeang-Su;Wang, Wen;Kim, Geun-Young;Yang, Sang-Sik
    • 마이크로전자및패키징학회지
    • /
    • 제12권3호
    • /
    • pp.267-274
    • /
    • 2005
  • This paper presents the fabrication of surface acoustic wave (SAW)-based pressure sensor for long-term stable mechanical compression force measurement. SAW pressure sensor has many attractive features for practical pressure measurement: no battery requirement, wireless pressure detection especially at hazardous environments, and easy other functionality integrations such as temperature, humidity, and RFID. A $41^{\circ}$ YX $LiNbO_3$ piezoelectric substrate was used because of its high SAW propagation velocity and large values of electromechanical coupling factors $K^2$. A silicon substrate with $\~200{\mu}m$ deep cavity was bonded to the diaphragm with epoxy, in which gold was covered all over the inner cavity in order to confine electromagnetic energy inside the sensor, and provide good isolation of the device from its environment. The reflection coefficient $S_{11}$ was measured using network analyzer. High S/N ratio, sharp reflected peaks, and clear separation between the peaks were observed. As a mechanical compression force was applied to the diaphragm from top with extremely sharp object, the diaphragm was bended, resulting in the phase shifts of the reflected peaks. The phase shifts were modulated depending on the amount of applied mechanical compression force. The measured $S_{11}$ results showed a good agreement with simulated results obtained from equivalent admittance circuit modeling.

  • PDF

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

Ar 가스압력과 RF 전력변화 (13.56MHz)에 따른 유도결합형 플라즈마 E-H 모드 변환의 광학적 특성 (Optical Properties of Inductively Coupled Plasma with Ar Gas Pressure and RF Power (13.56MHz))

  • 허인성;조주웅;이영환;김광수;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this paper, the emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma. To transmit the electromagnetic energy into the chamber, a RF power of 13.56MHz was applied to the antenna and considering the Ar gas pressure and the RF electric power change, the emission spectrum, Ar- I line, luminance were investigated. At this time the input parameter for ICP RF plama, Ar gas pressure and RF power were applied in the range of $10{\sim}60m$ Torr, $10{\sim}300W$ respectively.

  • PDF

유도결합형 플라즈마에서 압력에 따른 Ar Gas의 전기적 특성분석 (Analysis of Electrical Properties of Ar Gas According to Input Pressure for Inductively Coupled Plasma)

  • 조주웅;이영환;허인성;김광수;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1176-1179
    • /
    • 2003
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56 [MHz] have been measured over a wide range of power at gas pressure ranging from $1{\sim}70$ [mTorr].

  • PDF

표면 및 몸체 미세 가공 기술로 제작된 대기압에서 동작하는 전자력 검출형 각속도계의 연구 (A Surface-Bulk Micromachined Electromagnetic Gyroscope Operating at Atmospheric Pressure)

  • 김성혁;김용권;송진우;이장규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2230-2232
    • /
    • 2000
  • This paper reports an electrostatically driven and electromagnetically sensed planar vibratory gyroscope based on a surface-bulk combined micromachining. The fabricated structure has comb electrodes which are 400${\mu}m$ thick, 18${\mu}m$ wide, 600${\mu}m$ long and separated by 7${\mu}m$ so that the height-gap ratio is about 57. It also has electroplated gold springs which are 15${\mu}m$ wide, 14${\mu}m$ thick and 500${\mu}m$ long on both sides of the seismic mass. The open-loop characteristics of fabricated gyroscope at atmospheric pressure are measured on a rate table. The fabricated gyroscope has a sensitivity of 30mV/deg/sec, and a resolution of 0.1deg/sec at atmospheric pressure. It is expected that non linearity of full scale output is less than 0.8% with. the dynamic range of $\pm$500deg/sec.

  • PDF