Implementation and Performance Analysis of the Single Channel Monopulse System (단일채널 모노펄스시스템의 구현 및 성능 검증)

  • Kang, Byoung-Wook;Kwon, Hyuk-Ja;Lee, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.900-908
    • /
    • 2016
  • In this paper, we have studied the tracking system with a single channel monopulse receiver that has a comparative advantage of costs, size, weight, and power consumption over the general 3-channel monopulse receivers. After the single channel monopulse system was composed of an antenna, a monopulse receiver, a servo unit, a RF signal processor unit and a power supply unit, we analyzed the basic tracking performance of the tracking error angle and the pointing loss. And we proved the tracking performance to a moving target in the outdoor environment. On the Analysis of the tracking test results, the single channel monopulse system shows a equal or higher performance over the general 3-channel monopulse system and also has advantages of the system implementation. Also, it is concluded that this study is useful to apply a single channel monopulse receiver with benefits of production price and miniaturization when the monopulse tracking systems will be developed in the future.

A 900 MHz ZigBee CMOS RF Transceiver Using Switchless Matching Network (무스위치 정합 네트워크를 이용한 900 MHz ZigBee CMOS RF 송수신기)

  • Jang, Won Il;Eo, Yun Seong;Park, Hyung Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.610-618
    • /
    • 2017
  • This paper presents a 868/915 MHz CMOS RF transceiver for the ZigBee application. Using a switchless matching network, the off chip switch is removed to achieve the low cost RF transceiver, and by the elimination of the switch's insertion loss we can achieve the benefits for the RF receiver's noise figure and transmitter's power efficiency at the given output power. The receiver is composed of low-noise amplifier, mixer, and baseband analog(BBA) circuit. The transmitter is composed of BBA, mixer, and driver amplifier. And, the integer N type frequency synthesizer is designed. The proposed ZigBee RF full transceiver is implemented on the $0.18{\mu}m$ CMOS technology. Measurement results show that the maximum gain and the noise figure of the receiver are 97.6 dB and 6.8 dB, respectively. The receiver consumes 32 mA in the receiver mode and the transmitter 33 mA in the transmission mode.

A High-Efficiency 2 GHz Balanced Pulse Generator for Ground Penetrating Radar System (평형구조를 이용한 지표투과레이다용 2 GHz 대역 고효율 펄스발생기)

  • Jeong, Heechang;Seo, Munkyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.928-931
    • /
    • 2017
  • This paper presents a 2 GHz pulse generator in balanced configuration for ground penetrating radar(GPR). In order to improve the input and output matching, the pulse generator is designed in balanced configuration with $90^{\circ}$ hybrid couplers. The designed pulse generator was fabricated using PCB process. The fabricated pulse generator draws 1 mA current from a 5 V power supply with 27.6 % efficiency. The measured output voltage swing is $3.7V_{pp}$ at 100 MHz pulse repetition frequency(PRF). The pulse width is 2 ns and the input and output return loss is more than 10 dB at the operating frequency of 1.7~2.6 GHz.

A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

Study on Leading-phase Operation Capability of a 770 MW Jumbo Hydro-generator based on Stability Analysis and End-Region Heat Analysis

  • Fan, Zhen-nan;Zhou, Zhi-ting;Li, Jian-fu;Wen, Kun;Wang, Jun;Sun, Zhang;Wang, Tao;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1317-1325
    • /
    • 2018
  • A generator-grid coupling calculation model is established to study the leading-phase operational capability of a 770 MW jumbo hydro-generator in a Chinese ultra-mega hydropower station. The static and dynamic stability of the generator are analyzed and calculated to obtain stability limits under leading-phase operating conditions. Three-dimensional (3D) time-varying nonlinear moving electromagnetic and temperature field models of the generator end-region are also established and used to determine the magnetic field, loss, and temperature of the end-region under the leading-phase operating condition. The simulation results agree with data measured from the actual 770 MW hydro-generator. This paper provides reliable reference data for the leading-phase operation of a jumbo hydro-generator, which will help to improve in the design and manufacture of future hydro-generators.

Stacked Slot Patch Antenna for Wireless Sensors Embedded in Concrete (콘크리트 매립 센서를 위한 이중 슬롯 패치 안테나)

  • Lee, Jae-Hyuk;Lee, Sung-Ho;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.915-923
    • /
    • 2018
  • A concrete embedded antenna design is proposed for probing the durability of a building at an industrial scientific medical band of 902~908 MHz. The proposed antenna is designed with a stacked slot patch structure for lower impedance variation to a dielectric constant of concrete, as a dielectric constant difference is derived from the moisture content. The proposed structure has a wider bandwidth when a parasitic patch structure is used, which reduces antenna performance degradation resulting from the moisture content of concrete. The measured voltage standing wave ratio of the proposed structure is less than 2 and the beam width is approximately $80^{\circ}$, whereas the gain is greater than 7 dBi. The proposed antenna is fabricated with a rectangle-type concrete block, which is simulated and measured for return loss and antenna gain.

An Experimental Study on Construction Efficiency of High-Frequency Arc Metal Spray Machine (고주파 아크 금속용사 장치의 시공성능 평가에 관한 실험적 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.481-488
    • /
    • 2020
  • The arc thermal metal spraying method (ATMSM) has been used in Korea to improve the electromagnetic pulse (EMP) shielding effect of building and infrastructure by three machines of MS, KMS and HMS (Metal Spray, Korea Metal Spray, High-frequency Meta Spray). The adhesion ability of sprayed metal was found to be 58.32, 64.66 and 87.62% for MS, KMS and HMS, respectively. The metal sprayed area per hour of MS, KMS and HMS was calculated and found to be 14.3, 19.25 and 22.16㎡/h, respectively. The HMS showed the highest metal spray area attributed to the diameter of metal wire i.e. 1.6mm which sprayed 80 mm with 18 m/min. There was minimum loss of metal and the highest efficiency by HMS compared to others. Therefore, it is suggested to use HMS for metal spraying by ATMSM to enhance the EMP shielding effect.

Lower Characteristic Impedance Based Compact f λ0/4 Short-Circuited Stub UWB Bandpass Filter with WLAN Stopband (저특성 임피던스의 λ0/4 단락 스터브 기술을 이용한 WLAN 저지 대역을 가지는 UWB BPF)

  • Hoa, Duong Thai;Joo, Hyo-Suk;Kim, Ihn-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.4
    • /
    • pp.323-332
    • /
    • 2009
  • In this paper, we introduce a modified short-circuited stub bandpass filter suitable for ultra-wideband(UWB) applications utilizing low temperature co-fired ceramic(LTCC) technology. By modifying the conventional short-circuited stub bandpass filter structure with stubs and connecting lines of lower characteristic impedances, the number of stubs has been reduced from 5 to 2 on a high dielectric constant substrate($\varepsilon_r$ = 40). A wireless local area network (WLAN) stopband in the frequency range of 5.15 to 5.825 GHz has been inserted into the filter characteristic using three short-circuited coupled lines. The filter has been measured with an insertion loss less than 1.0 dB and return loss better than 10 dB in the pass bands. A bandwidth ratio of 109.49 % has been achieved. Measurement results agree well with simulation results. The dimensions of the filter are $4{\times}8{\times}0.57\;mm^3$.

H-Plane 8-Way Rectangular Waveguide Power Divider Using Y-Junction (Y-Junction을 이용한 H-평면 8-Way 구형 도파관 전력 분배기)

  • Lee, Sang-Heun;Yoon, Ji-Hwan;Yoon, Young-Joong;Kim, Jun-Yeon;Lee, Woo-Sang;Park, Seul-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.151-158
    • /
    • 2012
  • This paper proposes a H-plane 8-way rectangular waveguide power divider using Y-junction. A general N-way power divider can be composed of multi-stage T-junctions. However, if the distances of output ports are close, the matching characteristic is not improved by using only T-junctions because of space limitation. In this case, since other types of 3-port junctions should be used to final output stage, Y-junctions are used with T-junctions in this paper. The proposed Y-junction uses the tapered-line impedance transformer and inductive irises to improve impedance matching characteristic. The 8-way power divider using Y-junction is fabricated and measured. The measured return loss and insertion loss from input port to output port are -30.8 dB and -9.3 dB at operating frequency, respectively. The measured maximum phase difference is about $1^{\circ}$. Therefore, the proposed power divider will be useful to apply to various microwave systems, which need to divide the input power equally, such as feed networks for array antennas.

Highly Linear Wideband LNA Design Using Inductive Shunt Feedback (Inductive Shunt 피드백을 이용한 고선형성 광대역 저잡음 증폭기)

  • Jeonng, Nam Hwi;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1055-1063
    • /
    • 2013
  • Low noise amplifiers(LNAs) are an integral component of RF receivers and are frequently required to operate at wide frequency bands for various wireless systems. For wideband operation, important performance metrics such as voltage gain, return loss, noise figures and linearity have been carefully investigated and characterized for the proposed LNA. An inductive shunt feedback configuration is successfully employed in the input stage of the proposed LNA which incorporates cascaded networks with a peaking inductor in the buffer stage. Design equations for obtaining low and high input matching frequencies are easily derived, leading to a relatively simple method for circuit implementation. Careful theoretical analysis explains that poles and zeros are characterized and utilized for realizing the wideband response. Linearity is significantly improved because the inductor between gate and drain decreases the third-order harmonics at the output. Fabricated in $0.18{\mu}m$ CMOS process, the chip area of this LNA is $0.202mm^2$, including pads. Measurement results illustrate that input return loss shows less than -7 dB, voltage gain greater than 8 dB, and a little high noise figure around 7~8 dB over 1.5~13 GHz. In addition, good linearity(IIP3) of 2.5 dBm is achieved at 8 GHz and 14 mA of current is consumed from a 1.8 V supply.