• Title/Summary/Keyword: Electromagnetic field analyses

Search Result 45, Processing Time 0.027 seconds

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

Analysis of the Electromagnetic Phenomena in Vacuum Interrupter with Axial Magnetic Field Type (축자계형 진공인터럽터의 전자계 현상 해석)

  • 하성철;서상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.952-957
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation. The current distribution and magnetic field in simple models are analyzed to verify its efficiency and accuracy. In addition the validity of FEM is confirmed by performing the analyses of distribution in current density and magnetic flux density.

Analysis of the electromagnetic phenomena in vacuum interrupter with axial magnetic field type for Safety break (안전차단을 위한 축자계형 진공인터럽터의 전자계 현상 해석)

  • 서상현
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.4
    • /
    • pp.87-95
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena for the possess of Safety break. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation.

Electromagnetic Analysis of Slotless Brushless Permanent Magnet Machines According to Magnetization Patterns (슬롯리스 브러시리스 영구자석기기의 자화 패턴에 따른 전자기적 특성해석)

  • Jang Seok-Myeong;Choi Jang-Young;Cho Han-Wook;Park Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.576-585
    • /
    • 2005
  • This paper deals with the electromagnetic field analysis of slotless brushless permanent magnet machines with three different magnetization patterns such as Halbach, parallel and radial magnetization. The magnetization modeling of Halbach, parallel and radial magnetization is performed analytically. And then, analytical solutions for open-circuit field distributions, armature reaction field distributions, flux linkages due to PMs and stator windings, torque, back-emf and inductance are derived in terms of magnetic vector potential and two-dimensional (2-d) polar coordinate systems. The analytical results are validated extensively by finite element (FE) analyses. The magnet volume required in order to produce identical flux density is compared with each magnetization. Finally, analytical solutions and derivation procedures of those presented in this paper can be applied to slotless and slotted brushless permanent magnet AC and DC machines.

Movement Characteristics Analysis of Single Phase Transformer Winding Using Finite Element Method (유한요소법을 이용한 단상변압기권선의 운동특성해석)

  • Choi, Myoung-Jun;Kim, Hyung-Seok;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.104-106
    • /
    • 1996
  • In this paper, the dynamic motion driven by electromagnetic force of transformer windings is modeled and its characteristics are numerically analyzed. The electromagnetic field is obtained using the 2D finite element method taking account of anisotropic property of iron core, and the electromagnetic force on the transformer winding is calculated from Lorenz's force formula using the field distribution result. The system motion equation driven by electromagnetic force and gravitational force is numerically analyzed using the 4-order Runge-Kutta algorithm. Above analyses procedure is applied to a single-phase core-type transformer to validate its algorithm.

  • PDF

Electromagnetic-thermal two-way coupling analysis and application on helium-cooled solid blanket

  • Kefan Zhang;Shuai Wang;Hongli Chen
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.927-938
    • /
    • 2023
  • The blanket plays an important role in fusion reactor and stands extremely high thermal and electromagnetic loads during operation situation and plasma disruption event, brings the need for precise thermal and electromagnetic analysis. Since the thermal field and EM field interact with each other nonlinearly, we develop a method of electromagnetic-thermal two-way coupling by using finite element software COMSOL. The coupling analyses of blanket under steady state and MD event are implemented and the results are analyzed. For steady state, the influences of coupling effects are relatively small but still recommended to be considered for a high precision analysis. The influence of thermal field on EM field can't be ignored under MD events. The variation of force density could cause a significant change in stress in certain parts of blanket. The influence of Joule heat during MD event is negligible, yet the potential temperature rise caused by induced current after MD event still needs to be researched.

Design of an Electromagnetically-driven Micromirror Through the Coupled Physics Analyses (복합장 해석에 의한 전자력 구동방식의 마이크로미러 설계)

  • Han, Seung-Oh;Kim, Byoung-Min;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.380-384
    • /
    • 2010
  • A micromirror for a laser display system actuated by the electromagnetic force induced by the surface coil and the permanent magnet was designed and analyzed through the coupled physics analyses incorporating the electromagnetics, mechanics, and electrothermal analysis because the mechanical rotation of the micromirror is driven by the electromagnetic driving force. The proposed micromirror has two torsion beams to sustain the mirror plate which has surface coils on the top and the two permanent magnets exists on both sides of the micromirror for an external magnetic field source. The designed micromirror has the resonant frequency of 3.82kHz. When the magnetic field of the permanent magnet is 0.4T, the coil has 4 turns, and the current density of coil is 3.6A/$mm^2$, the estimated z axis displacement of the mirror plate edge is 0.23mm which corresponds to the rotation angle of $14.2^{\circ}$. When considering the joule heating in the current-carrying coil, the maximum temperature of the mirror plate is obtained as 300.045K, which induces the negligible changes in the rotation angle and the resistance of the coil.

A Study on the Electromagnetic Characteristics of a High Voltage Switchgear According to the Arrangements of Bus Bars to Improve Electrical Stabilities (고압배전반의 전기적 안정성 향상을 위한 버스바의 배치기법에 따른 전자기 특성에 관한 연구)

  • Nam, Seokho;Heo, Jeong Il;Hong, Jonggi;Kang, Hyoungku
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.216-220
    • /
    • 2013
  • The rated voltage has been rising in order to minimize the losses in power transmission. The high voltage electric machines should be minimized due to the constraints of space. Therefore, the temperature of high voltage electric apparatuses easily exceeds the temperature limits. In this paper, it is investigated that how to minimize the internal temperature rising of a high voltage switchgear by adjusting the arrangement of bus bars. High voltage switchgears consist of a circuit breaker, a CT, a PT, a earthing switches, bus bars, and so on. It is very difficult to estimate the electromagnetic properties of a high voltage switchgear due to these various environments and structures. In this paper, analyses are focused on the electromagnetic characteristics of bus bars according to the arrangement method and the enclosures to simplify the electromagnetic characteristics of a switchgear. It is found that the characteristics of electric field intensity and electromagnetic losses in bus bars are influenced by the arrangement method of bus bars. However, it is confirmed that the electromagnetic characteristics of enclosures are not affected by the arrangement of bus bars. In this paper, the arrangement methods of bus bars to minimize the electric field intensity and electromagnetic losses are suggested. It is expected that the research results are helpful to design and develop an electrically reliable high voltage switchgear.

Electromagnetic Field Analyses of Electrodeless Fluorescent Lamp (무전극 전구형 형광램프의 전자계 해석)

  • Kim, Kwang-Soo;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dea-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.67-70
    • /
    • 2002
  • The electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux, B, H, by changing the input current.

  • PDF

Electromagnetic field and initial stress on a porothermoelastic medium

  • Abd-Elaziz, Elsayed M.
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • In this study, the porothermoelastic problem with the effect of the magnetic field and initial stress was investigated. We applied normal mode analysis to solve the resulting non-dimensional coupled equations. Numerical results for the displacements, temperature distribution, pore pressure, stresses, induced electric field and induced magnetic field distributions are presented graphically and discussed. The medium deformed because of thermal shock and due to the application of the magnetic field, there result an induced magnetic and an induced electric field in the medium. Numerical analyses are given graphically on the square (2D) and cubic (3D) domains to illustrate the effects of the porosity parameter, magnetic field and initial stress parameter on the physical variables.