• 제목/요약/키워드: Electromagnetic Transient Simulation

검색결과 75건 처리시간 0.029초

영구자석형 전자접촉기의 동작특성 해석 (The Operating Characteristic Analysis of PM-type MAGNETIC CONTACTOR)

  • 조현길;이은웅;김길수;김일중;김성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.792-794
    • /
    • 2000
  • This paper describes the design and the analysis of electromagnetic system of Magnetic Switch using 2D parametric finite element method(EM-Pulse). Magnetic Switch is electrical equipment, which is widely used for switching on/off motors in industrial field. The transient state is simulated in order to calculate the response time of Magnetic Switch. The simulation is based upon a step-by-step integration of the electric circuit equations and the core movement. The contactor uses a permanent magnet for maintaining the closed state. The presented solution takes account of non-linear magnetic material property and spring force controlled by core position. The dynamic response of Magnetic Switch predicted by the simulation agrees closely with the required condition.

  • PDF

The Overview of a Digital Power System Simulator for Large Power System Analysis

  • Kim, Tae-Kyun;Kim, Yong-Hak;Shin, Jeong-Hoon;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.93-99
    • /
    • 2003
  • This paper deals with the development and testing of a large-scale, realtime digital power system simulator for the Korean Electric Power Corporation. The KEPS Simulation Center is located at KEPCO's research center (KEPRI) in Taejon, South Korea and has been operated since September 2001. The KEPS Simulation Center includes a wide range of off line power system simulation and analysis tools, as well as an advanced realtime digital simulator for the study of large scale AC and DC system performance. Because the application scope of the KEPS realtime simulator is broad and because the network models being considered are significantly larger and more complex than in traditional realtime simulator applications, many developments and tests have been required during the course of the project. In this paper, the authors describe some of these developments and present results from various benchmark tests that have been performed.

배전시스템에서의 파라미터에 따른 과도현상 분석 (Transients Analysis for Parameters on Electrical Distribution System)

  • 김재철;오정환;임성정
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권3호
    • /
    • pp.88-96
    • /
    • 1997
  • 본 논문은 배전시스템에서의 파라미터에 따른 과도현상을 분석하였다. 재투입에 의한 순간전압강하와 개폐서지를 분석하였으며, 이를 위해서 22.9[kV] 배전시스템의 실 데이터를 이용하여 다중접지된 모델 시스템을 구성하였다. EMTP 시뮬레이션을 통하여 주상변압기 2차측 수용가에서의 재투입 영향을 분석하였으며, 사고선로와 인근선로에서의 과도현상을 나타냈었다. 또한 사고위치, 부하크기, 부하역률, 캐패시터뱅크의 크기, 재투입 위상각에 대한 파라미터 분석을 하였고, 이들 요소와 재투입에 의한 과도 현상과의 관계를 나타내었다.

  • PDF

인터리브드 RPWM Buck 컨버터의 전도성 노이즈 감소에 대한 연구 (Reduction of Conducted Emission in Interleaved RPWM Buck Converter)

  • 이승현;이근봉;나완수
    • 한국전자파학회논문지
    • /
    • 제28권4호
    • /
    • pp.298-308
    • /
    • 2017
  • 본 논문에서는 DC-DC Converter에서의 고조파로 인한 전자기적 잡음을 줄이기 위해 Random PWM을 적용한 Interleaved Buck Converter(IBC) 시스템을 제안한다. PWM 직류전원장치에서 스위칭 방식을 사용하는 경우 스위칭 손실 및 EMI 문제가 발생하기 때문에 많은 고조파를 포함하고 있어 선간 전압의 왜곡 등을 유발한다. 따라서 이에 대한 해결방법으로 PRBS를 이용한 IBC를 최초로 제안한다. 이 방식의 회로 구조는 2개의 능동형 스위치를 가지며 180도의 위상차를 갖는 2개의 PWM 신호를 이용하여 회로를 제어한다. IBC는 1세트의 스위치를 추가하기 때문에, 비용 측면 등에서는 불리 할 수 있으나 전력분배, 출력전류 리플 감소, 빠른 회로 반응속도, 수동소자크기 감소의 이점을 가진다. 본연구의 타당성을 확인하기 위하여 PSIM 시뮬레이터를 이용하였고 Random PWM을 적용한 IBC 회로를 설계하여 기존의 PWM과 RPWM 방식만을 사용하는 Buck-converter 회로를 PSIM 시뮬레이터를 이용하여 결과를 확인하고 분석하였다.

고주파유도 급속 금형가열 과정의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of the Induction Heating Procedure of an Injection Mold)

  • 손동휘;서영수;박근
    • 소성∙가공
    • /
    • 제19권3호
    • /
    • pp.152-159
    • /
    • 2010
  • Rapid mold heating has been recent issue to enable the injection molding of thin-walled parts or micro/nano structures. High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a non-contact manner, and has been recently applied to the injection molding due to its capability of rapid heating and cooling of mold surface. The present study covers a three-dimensional finite element analysis to investigate heating efficiency and structural safety of the induction heating process of an injection mold. To simulate the induction heating process, an integrated simulation method is proposed by effectively connecting an electromagnetic field analysis, a transient heat transfer analysis and a thermal stress analysis. The estimated temperature changes are compared with experimental measurements for various types of induction coil, from which heating efficiency according to the coil shape is discussed. The resulting thermal stress distributions of the mold plate for various types of induction coils are also evaluated and discussed in terms of the structural safety.

Finite Control Set Model Predictive Control of AC/DC Matrix Converter for Grid-Connected Battery Energy Storage Application

  • Feng, Bo;Lin, Hua
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1006-1017
    • /
    • 2015
  • This paper presents a finite control set model predictive control (FCS-MPC) strategy for the AC/DC matrix converter used in grid-connected battery energy storage system (BESS). First, to control the grid current properly, the DC current is also included in the cost function because of input and output direct coupling. The DC current reference is generated based on the dynamic relationship of the two currents, so the grid current gains improved transient state performance. Furthermore, the steady state error is reduced by adding a closed-loop. Second, a Luenberger observer is adopted to detect the AC input voltage instead of sensors, so the cost is reduced and the reliability can be enhanced. Third, a switching state pre-selection method that only needs to evaluate half of the active switching states is presented, with the advantages of shorter calculation time, no high dv/dt at the DC terminal, and less switching loss. The robustness under grid voltage distortion and parameter sensibility are discussed as well. Simulation and experimental results confirm the good performance of the proposed scheme for battery charging and discharging control.

레이저-GMA 하이브리드 용접에서 유동에 의한 기포 및 기공 형성 해석 (Numerical Simulation of Bubble and Pore Generations by Molten Metal Flow in Laser-GMA Hybrid Welding)

  • 조원익;조정호;조민현;이종봉;나석주
    • Journal of Welding and Joining
    • /
    • 제26권6호
    • /
    • pp.67-73
    • /
    • 2008
  • Three-dimensional transient simulation of laser-GMA hybrid welding involving multiple physical phenomena is conducted neglecting the interaction effect of laser and arc heat sources. To reproduce the bubble and pore formations in welding process, a new bubble model is suggested and added to the established laser and arc welding models comprehending VOF, Gaussian laser and arc heat source, recoil pressure, arc pressure, electromagnetic force, surface tension, multiple reflection and Fresnel reflection models. Based on the models mentioned above, simulations of laser-GMA hybrid butt welding are carried out and besides the molten pool flow, top and back bead formations could be observed. In addition, the laser induced keyhole formation and bubble generation duo to keyhole collapse are investigated. The bubbles are ejected from the molten pool through its top and bottom regions. However, some of those are entrapped by solid-liquid interface and remained as pores. Those bubbles and pores are intensively generated when the absorption of laser power is largely reduced and consequently the full penetration changes to the partial penetration.

벡터 적합을 이용한 전자기 과도현상 및 고조파 시뮬레이션 (Electromagnetic Transient and Harmonic Simulation Using Vector Fitting)

  • 왕용필;안준호;박민영;김경훈;허동렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.125_126
    • /
    • 2009
  • 전력시스템 전자기 과도현상은 시간 영역에서 정확하고 효과적으로 해속되어져야 한다. 그러나 대규모 전력시스템을 상세하게 표현하기 위해서는 엄청난 계산량이 필요하다. 따라서 전력시스템 과도현상을 해석하기 위하여 전력시스템의 작은 부분은 상세하게 표현하고, 나머지 부분은 효과적으로 등가 시스템이 필요하다. 본 논문에서는 모든 주파수 영역에서 등가 시스템을 개발하기 위하여 벡터 적합을 이용하여 Z 영역 유리함수 계수를 추정하여 주파수 의존 등가 시스템을 개발하였다. 개발한 FDNE의 우수성을 입증하기 위하여 테스트 시스템에 적용하여 시스템이 고장시 전자기 과도현상 및 고조파 평가를 비교 검토하였다.

  • PDF

패턴인식형의 신경회로망 거리계전 기법 (Pattern Recognition based Neural Networks Distance Relaying Scheme)

  • 이복구;윤석무;박철원;정호성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.871-874
    • /
    • 1997
  • A new typed distance relaying scheme is proposed. Artificial neural networks are applied to the distance relaying system composed of pattern recognition based. The proposed distance relaying scheme have the two block of pattern recognition stages to estimate the fundamental frequency and to classify the fault types. The advantage of this approach is demonstrated by the random waves and the fault transient wave signals of EMTP(electromagnetic transients program) in power systems fault conditions. The proposed method is compared with the conventional method and the simulation results show the efficiency of the neural networks.

  • PDF

인버터구동 고압전동기 열화특성 분석 및 필터 설계기법 확립 (Insulation System and Filter Design for Inverter-Fed Motor)

  • 최영찬;이상동;김익모;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2000
  • Recently, the insulation breakdown accident happened at 6.6kV inverter driving motor brings out the reliability decrease to the motor driving system. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the insulation system of motor which is driven by inverter. The circuit parameters of cable are calculated by EMTP(Electromagnetic Transient Program) to simulate the system. And we use MATLAB to find the appropriate filter parameter. The simulation and the test results are compared to verify the suitability of the filter parameter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of insulation breakdown accidents. The endurance test scheme and the configuration method of insulation system are established.