• Title/Summary/Keyword: Electromagnetic Transient Simulation

Search Result 75, Processing Time 0.026 seconds

Analysis on the Effect of LCR Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter (멀티레벨 인버터 구동 고압유도전동기에시 발생하는 과도과전압 저감을 위한 LCR필터의 효과분석)

  • Kim, Jae-Chul;Kwon, Young-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.45-52
    • /
    • 2006
  • In this paper, we analyze on the effect of LCR filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage that it was occurred in inverter appears transient overvoltage at the motor input terminal. the transient overvoltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of transient overvoltage appears more serious in high voltage induction motor than low voltage induction motor. We selected LCR filter for reduction of the transient overvoltage. Consequently, we demonstrated that the LCR filter connected to the invertor output terminals greatly reduces the transient voltage stress and ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear (가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석)

  • Chung, Y.H.;Lee, D.S.;Kim, J.B.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter (증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1211-1217
    • /
    • 2007
  • In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

Excitation System Stress in Synchronous Machine Connected to HVDC System (HVDC 단에 연결된 동기기의 여자시스템 스트레스)

  • Kim, Chan-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

A Study on the Parameter Optimization of Inverter for Induction Heating Cooking Appliance (유도가열 조리기기용 인버터 파라미터 최적화에 관한 연구)

  • Kang, Byung-Kwan;Lee, Se-Min;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • With the advent of power semiconductor switching devices, power electronics relating to high frequency electromagnetic eddy current based induction heating technology have become more suitable and acceptable. This paper presents high-frequency induction heating cooking appliance circuit based on the zero current switching-PWM single ended push-pull(ZCS-PWM SEPP) resonant inverter added AC-DC converter. This inverter uses pulse-width-modulation(PWM) control method with active auxiliary quasi-resonant lossless inductor snubbers and a switched capacitor. To improved the transient performance, the PI controller is applied for this system. For the systematic parameter optimization of the PI controller, the gradient-based optimization algorithm is applied. The performance of optimized parameters is evaluated using simulation and experimental test. These results show that the proposed systematic optimal tuning method improve the transient performances of this system.

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

A Study on the Induction Heating Analysis of Round bar for TR forging (TR단조를 위한 환봉의 유도가열 해석에 관한 연구)

  • Song, M.C.;Park, D.S.;Lee, M.G.;Lee, K.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.194-197
    • /
    • 2009
  • The TR forging is a kind of continuous grain flow forging. The preform of crank shaft for TR forging process was a round bar with a ring groove. In the first stage, the preform was partly heated by induction heating and then forged by vertical and horizontal force in sequence. In this study, the simulation process of induction heating was proposed to evaluate the temperature distribution of preform for TR forging. The equivalent circuit method was adopted to find coil current of the preform with a various dimensions and power levels. With these results, the coupled electromagnetic and transient thermal analysis for induction heating was performed to evaluate the temperature distribution at the preform of crank shaft during induction heating process. This FE analysis technique with equivalent circuit method was verified by comparing the analysis results with the experimental results.

  • PDF

Dynamic Characteristic Analysis of Electric Actuator for 1 kV/3.2 kA Air Circuit Breaker Based on the Three-link Structure

  • Lee, Seung-Min;Kang, Jong-Ho;Kwak, Sang-Yup;Kim, Rae-Eun;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.613-617
    • /
    • 2011
  • In the present paper, a new type of electrical actuator, an electromagnetic force driving actuator (EMFA), applicable to air circuit breaker is developed and analyzed. Transient analysis is performed to obtain the dynamic characteristics of EMFA. The distribution of static magnetic flux is obtained using the finite element method. The coupled problems of electrics and mechanics governing equations are solved using the time-difference method. According to the interception rate of each contactor, investigation of the contactor spring load condition is conducted and applied to the threelink system. Comparisons of the dynamic characteristics of the three-link simulation and experimental data are performed.

Analytical Investigation on Fundamental Electrical Characteristics of Large Air-gap Superconducting Synchronous Machine

  • Yazdanian, M.;Elhaminia, P.;Zolghadri, M.R.;Fardmanesh, M.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.260-267
    • /
    • 2013
  • In this paper a general 2-D model of a large air-gap synchronous machine either with non-magnetic or magnetic core rotor is investigated and electrical characteristics of the machine are analytically calculated. Considering the general model, analytical equations for magnetic field density in different regions of the large air-gap machine are calculated. In addition, self and mutual inductances in the proposed model of the machine have been developed, which are the most important parameters in the electromagnetic design and transient analysis of synchronous machines. Finite element simulation has also been performed to verify the obtained results from the equations. Analytical results show good agreement with FEM results.

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.