• Title/Summary/Keyword: Electromagnetic Transient Program

Search Result 98, Processing Time 0.037 seconds

Reduction of Conducted Emission in Interleaved RPWM Buck Converter (인터리브드 RPWM Buck 컨버터의 전도성 노이즈 감소에 대한 연구)

  • Lee, Seunghyun;Lee, Keunbong;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.298-308
    • /
    • 2017
  • This paper presents a Interleaved Buck Converter(IBC) system with Random PWM to reduce electromagnetic noise by harmonics. Swithced mode power supply generally controlled by high switching frequency have a electromagnetic interference(EMI) issue due to the high-voltage/high-current switching to regulate the voltage in buck converter. To solve the problem. we present a novel IBC system with PRBS. IBC system has two active switches with 180 phase difference that controll the cicuit with two PWM signal. IBC system may be disadventageous for the cost due to the addtion of one set of switch, but it has adventages of power distribution, current ripple cancellation, fast transient response, and passive component size reduction. To verify the validity of study, simulation program has been bulit using PSIM and the experimental results of IBC system using RPWM was compared with the conventinal PWM and randomized PWM.

Prediction and Measurement of Induction Phenomena in the 765 kV Double Circuit Transmission Line operated with two voltage grades (765 kV 송전선로에서의 이종 전압등급 병행 운전시의 유도현상 예측 및 실측 결과)

  • Kwak, J.S.;Kang, Y.W.;Shim, E.B.;Jeon, M.R.;Woo, J.W.;Bang, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.208-211
    • /
    • 2003
  • The western route of KEPCO's 765 kV transmission line has been tentatively operating as 345 kV voltage before commercial operation. KEPCO decided to operate the 765 kV line for commercial operation after completing the test operation of 765 kV substation in 2002. In the process of energizing the line as 765 kV voltage, double circuit transmission line will be operated with two voltage grades of 765 kV and 345 kV. As the earthing switches are installed on both ends of the line, electrostatic induction voltage and electromagnetic induction current were calculated prior to the line energizing in order to confirm the ratings. The induced voltage and current are important for the maintenance of the parallel circuit. This paper presents the simulation results of electrical phenomena such as electrostatic induction voltage and electromagnetic induction current from the parallel line. The transmission line was modeled by EMTP (Electro-Magnetic Transient Program). The simulation results were compared with the measured results at the field.

  • PDF

Analysis of Power Quality by Transformer Inrush Current (변압기 여자돌입에 의한 전력품질 분석)

  • Seo, Hun-Chul;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Young-Sik;Cho, Burm-Sup
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.932-937
    • /
    • 2008
  • The transformer inrush current can cause a voltage drop by source impedance. This current can impact sensitive loads by the voltage drop. Therefore, it is necessary to take measures to limit this inrush current. This study, described in this paper, analyzes the power quality affected by transformer inrush current using the X power system in Korea. The Electromagnetic Transients Program(EMTP) is used to analyze the transient phenomenon. We discuss a method to model the hysteresis curve of the transformer in EMTP. We carried out various simulations to analyze the power quality during transformer energization. The analysis results of voltage drop by the inrush current occurrence when certain requirements are met are presented.

Travelling Wave Technique for Close-Up Fault Protection (진행파를 이용한 근접사고 거리계전 방식)

  • Kim, Gon-Wook;Kang, Sang-Hee;Park, Jong-Keun;Kim, Il-Dong;Yun, Man-Cheol;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.202-205
    • /
    • 1990
  • In this paper the development of new technique based on the travelling-wave information contained in the post fault voltage and current signals has been presented. To develop fault location methods which can cope with close-up fault and zero-inception angle problems, magnitude of the backward wave has been used. The technique developed can be incorporated in a generalized algorithm for application as a high speed distance scheme. In this way some of the problems and limitations associated with travelling wave schemes are avoided. Verification of the relay operating principles is presented through digital computer numerical simulation using an electromagnetic transient program(EMTP) in conjunction with simulation of the proposed algorithms.

  • PDF

Classification of High-Impedance Faults based on the Chaotic Attractor Patterns (카오스 어트랙터 패턴에 의한 고저항 지락사고의 분류)

  • Shin, Seung-Yeon;Kong, Seong-Gon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1486-1491
    • /
    • 1999
  • This paper presents a method of recognizing high impedance fault(HIF) of electrical power systems and classifying fault patterns based on chaos attractors. Two dimensional chaos attractors are reconstructed from neutral point current waveforms. Reliable features for HIF pattern classification are obtained from the chaos attractors. Radial basis function network, trained with two types of HIF data generated by the electromagnetic transient program and measured form actual faults. The RBFN successfully classifies normal and the three types of fault patterns according to the features generated from the chaos attractors.

  • PDF

The Modeling of EV Fast Charging System using EMTP (EMTP를 이용한 전기자동차용 급속 충전시스템 모델링)

  • Ju, Seong-Chul;Shim, Hyong-Wook;Lee, Jae-Won;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.203-204
    • /
    • 2011
  • There is a growing interest on Electric Vehicles due to global warming and greenhouse gas emission issue. Recently, new technologies of EV fast charging are continually being developed and power supply infrastructure technologies are being developed widely. In general, the fast charging system consists of AC-DC converter, DC-DC converter, and filters. This paper performs modeling of Electric Vehicle fast charging system using EMTP(Electromagnetic transient program).

  • PDF

A Decision Scheme for Optimal Insertion Resistance in Superconducting Fault Current Limiter for Reduction of the Transformer Inrush Current (여자돌입전류 제한용 초전도한류기의 최적투입저항 결점)

  • Seo, H.C.;Rhee, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.37-39
    • /
    • 2008
  • This paper suggests a decision scheme for optimal insertion resistance in an Superconducting Fault Current Limiter (SFCL) application to reduce the transformer inrush current. This scheme and the SFCL model are implemented using Electromagnetic Transient Program (EMTP). We determine the optimal SFCL resistance by EMTP simulation, and this value is applied to model the SFCL by EMTP. The simulation results show the validity and effectiveness of the suggested scheme and the ability of a SFCL to reduce the inrush current.

  • PDF

Analysis of closing surge in static condenser bank using EMTP (EMTP를 이용한 스타콘뱅크의 투입써-지 해석)

  • Won, Young-Jin;Seo, Soon-Gyo;Jung, Tay-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.673-675
    • /
    • 1992
  • The operation of condenser-bank is now increasing around Kyoungin area. The operation of condenser-bank is used for the improvement of under voltage and expand of power demand. But the operation has the problem in itself as the switching over voltage. This report deals with the static-condenser fault caused by abnormal operation of circuit breaker which has occurred last summer. We have analyzed this fault using EMTP(electromagnetic transient program).

  • PDF

Development of new reclosing scheme considering the superconducting fault current limiter (초전도 한류기를 고려한 재폐로 차단기 동작 scheme 개발)

  • Ko, Yun-Tae;Seo, Hun-Chul;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.135_136
    • /
    • 2009
  • This paper proposes the new reclosing scheme considering the recovery time of SFCL in distribution systems which is based on variable dead time control. The main idea is that it uses the carrier signal to distinguish whether the fault is instantaneous or permanent following initial recloser opening. The system and SFCL is modeled by using Electromagnetic Transient Program(EMTP) and the validity of the reclosing scheme represented in this paper is analyzed according to the value of the fault resistance and the time of the fault removal.

  • PDF

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.