• 제목/요약/키워드: Electromagnetic Transient Program

검색결과 98건 처리시간 0.028초

지중 전력 선로 편단접지 시스템에서의 병행지선 및 SVL 설치방안 (Installation Methodology of Parallel Ground Conductor and SVL for Single Point Bonding System on Underground Power Cable)

  • 하체웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.119-121
    • /
    • 2008
  • In underground power cable system, the device for limiting over-voltage is needed when transient over-voltage break out between sheath and ground. For this reason, the SVL(Sheath Voltage Limiter) has been applied on weak points. But the broken SVLs which are installed on the single point bonding system on underground cable are frequently found. In this paper, EMTP(Electromagnetic Transient Program) is utilized to analyze effects on the installation methodology of the parallel ground conductor and SVL for the single point bonding system on the underground cable. The result shows that the proposed installation methodology can be applied for single point bonding system and contribute for power system stabilization.

  • PDF

가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석 (EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear)

  • 정영환;이동수;김정배;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구 (A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter)

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1211-1217
    • /
    • 2007
  • In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

HVDC 단에 연결된 동기기의 여자시스템 스트레스 (Excitation System Stress in Synchronous Machine Connected to HVDC System)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

지중 송전 케이블의 편단접지 시스템에서의 계통 보호 방안 (Application of Protecting Methods for Single Point Bonding on Underground Transmission Cable)

  • 하체웅;김정년;이인호;김종철;이광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.15-17
    • /
    • 2005
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-line which is connected with overhead line and underground cable. This paper investigates the failure of SVL(Sheath Voltage Limiter) and presents the application of protection methods for single point bonding on underground transmission cable system. EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as, underground cables, SVLs and towers.

  • PDF

초전도 한류기 투입 위치에 따른 TRV 영향 분석 (Analysis of a TRV influence according to application position of a SFCL)

  • 방승현;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.91-92
    • /
    • 2008
  • The rating of a circuit breaker depends not only on the interrupting current but also on a transient recovery voltage (TRV). To achieve a successful interruption, the circuit breaker must withstand the TRV. A superconducting fault current limiter (SFCL) is a device that limits the fault current fast and effectively without having high impedance during normal operation of the power system. Therefore, we studied the influence of the TRV according to the application of a resistive type SFCL in distribution system. This paper analyses the influence of the TRV for various application position of the resistive SFCL. The distribution system and the resistive SFCL were modeled by using EMTP-RV (Electromagnetic Transient Program - Restructured Version)

  • PDF

실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책 (The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines)

  • 하체웅;김정년;이수길;허회덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF

Electric Arc furnaces: Chaotic Load Models and Transient Analysis

  • Jang, Gil-Soo;Venkata, S.S.;Kwon, Sae-Hyuk
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.923-925
    • /
    • 1998
  • Electric arc furnaces (EAFs) are a main cause of voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this paper, a chaotic approach to such modeling is described and justified. At the same time, a DLL (Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

분로 리액터용 개폐제어 차단기의 최적 개폐시점 선정 (Determination of Optimal Controlled Switching Instants for Circuit Breaker of Shunt Reactors)

  • 이우영;박경엽;정진교;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.664-669
    • /
    • 2002
  • In this paper the method to determine tire optimal switching instants in order to reduce the transient surges during switching not relevant to the neutral treatment of shunt reactors is presented. This method consists of the following two steps. First, the instants of the voltage peaks between the contacts of each poles and the voltage magnitude as well as the moments of the current zero crosses were found out analytically. Next, the instants of the contact touches or separations were determined in consideration of the rate of decrease of dielectric strength or a circuit breaker and the variation of the its operating time. The results obtained from the EMTP(Electromagnetic Transient Program) analysis studies show that the making instants are established at the peak voltage of each three poles for any conditions of a neutral point and the possible upper limited values of inrush currents due to the variation of the mechanical operating time can be estimated.

과도현상 해석을 위한 EAFs 부하 무델의 개발 (An Electric Arc Furnaces Load Model for Transient Analysis)

  • 장길수;;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF