• Title/Summary/Keyword: Electrolytic oxidation

Search Result 222, Processing Time 0.025 seconds

Morphology of Bone-like Apatite Formation on Sr and Si-doped Hydroxyapatite Surface of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation

  • Yu, Ji-Min;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.79-79
    • /
    • 2017
  • Metallic biomaterials have been mainly used for the fabrication of medical devices for the replacement of hard tissue such as artificial hip joints, bone plates, and dental implants. Because they are very reliable on the viewpoint of mechanical performance. This trend is expected to continue. Especially, Ti and Ti alloys are bioinert. So, they do not chemically bond to the bone, whereas they physically bond with bone tissue. For their poor surface biocompatibility, the surface of Ti alloys has to be modified to improve the surface osteoinductivity. Recently, ceramic-like coatings on titanium, produced by plasma electrolytic oxidation (PEO), have been developed with calciumand phosphorus-enriched surfaces. A lso included the influences of coatings, which can accelerate healing and cell integration, as well as improve tribological properties. However, the adhesions of these coatings to the Ti surface need to be improved for clinical use. Particularly Silicon (Si) has been found to be essential for normal bone, cartilage growth and development. This hydroxyapatite, modified with the inclusion of small concentrations of silicon has been demonstrating to improve the osteoblast proliferation and the bone extracellular matrix production. Strontium-containing hydroxyapatite (Sr-HA) was designed as a filling material to improve the biocompatibility of bone cement. In vitro, the presence of strontium in the coating enhances osteoblast activity and differentiation, whereas it inhibits osteoclast production and proliferation. The objective of this work was to study Morphology of bone-like apatite formation on Sr and Si-doped hydroxyapatite surface of Ti-6Al-4V alloy after plasma electrolytic oxidation. Anodized alloys was prepared at 270V~300V voltages with various concentrations of Si and Sr ions. Bone-like apatite formation was carried out in SBF solution. The morphology of PEO, phase and composition of oxide surface of Ti-6Al-4V alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Effect of Electrolyte Composition on The Formation Behavior of Plasma Electrolytic Oxidation Films on Al1050 Alloy (Al1050 합금의 플라즈마 전해산화 피막 형성 거동에 미치는 전해질 조성의 영향)

  • Kim, Ju-Seok;Mun, Seong-Mo;O, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.98.1-98.1
    • /
    • 2017
  • 본 연구에서는 정전류 조건에서 알루미늄 합금의 PEO(Plasma Electrolytic Oxidation) 피막 형성 거동에 대한 전해질 조성의 영향을 아크 발생 양상, 전압-시간 곡선 및 형성된 표면피막의 구조를 관찰하여 연구하였다. 실험에 사용된 전해질은 NaOH 수용액에 $Na_2SiO_3$을 혼합하여 구성되었으며, NaOH와 $Na_2SiO_3$의 농도는 각각 0.01 ~ 1.0 M 와 0 ~ 2.0 M 사이로 조절되었다. 0.01 M NaOH 이하의 용액에서는 양극전압이 500 V 이상으로 상승되고 미세한 아크가 시편 표면 전체에 발생했으나, 0.02 M NaOH 이상의 농도에서는 양극전압이 300 V 이하로 감소되었고 아크발생이 관찰되지 않았다. 아크발생이 일어나지 않는 고농도의 0.5 M NaOH 용액의 경우 0.1 M 이상의 $Na_2SiO_3$를 첨가하였을 때 작은 아크의 무리가 발생되었다. 0.5 M NaOH 수용액에 0.1 M ~ 0.2 M $Na_2SiO_3$가 첨가되었을 땐 아크 무리가 발생하나 이내 일부 영역에서만 반복적으로 아크가 발생하는 로컬 버닝 현상이 일어났다. 한편 0.5 M NaOH 수용액에 0.5 M 이상의 $Na_2SiO_3$가 첨가되었을 때는 로컬 버닝이 일어나지 않고 전 표면에 걸쳐서 아크 무리가 이동하며 PEO 피막이 형성되었다. 0.01 M NaOH 수용액에서 형성된 PEO 피막의 두께는 처리 시간에 따라 증가하지 않고 $10{\mu}m$ 이하의 낮은 값을 보였다. 반면에 NaOH와 $Na_2SiO_3$ 혼합수용액에서 형성된 피막의 두께는 약 $30{\mu}m$ 이상의 높은 값을 보였다.

  • PDF

Effect of Zn Content on the Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation

  • Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.159-159
    • /
    • 2017
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements are known to play an important role in the bone formation and also affect bone mineral characteristics. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing TiO2(Zn-TiO2)coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, effect of Zn content on the corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation were studied by SEM, EDS, XRD, AC impedance, and potentiodynamic polarization test. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67 mV/s and potential range from -1500 mV to +2000 mV. Also, AC impedance was performed at frequencies ranging from 10 MHz to 100 kHz for corrosion resistance.

  • PDF

Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation in Solutions Containing Ca, P and Zn

  • Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.120-120
    • /
    • 2016
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements, such as strontium (Sr), magnesium (Mg), zinc (Zn), sodium (Na), silicon (Si), silver (Ag), and yttrium (Y) are known to play an important role in the bone formation and also affect bone mineral characteristics, such as crystallinity, degradation behavior, and mechanical properties. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing $TiO_2(Zn-TiO_2)$coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation in solutions containing Ca, P and Zn were studied by scanning electron microscopy (SEM), AC impedance, and potentiodynamic polarization test. A series of $Zn-TiO_2$ coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to +2000mV. Also, AC impedance was performed at frequencies ranging from 10MHz to 100kHz for corrosion resistance.

  • PDF

Surface Treatment of Mg95Zn4.3Y0.7 Alloy Powder Consolidates using Plasma Electrolytic Oxidation (플라즈마 전해산화공정을 이용한 Mg95Zn4.3Y0.7 합금분말 성형체의 표면특성제어)

  • Kim, J.H.;Choi, H.S.;Kim, D.H.;Hwang, D.Y.;Kim, H.S.;Kim, T.S.
    • Journal of Powder Materials
    • /
    • v.15 no.2
    • /
    • pp.95-100
    • /
    • 2008
  • The investigation is to modify the mechanical and chemical properties of Mg alloys using a combination of rapid solidification and surface treatment. As the first approach, $Mg_{95}Zn_{4.3}Y_{0.7}$ was gas atomized and pressure sintered by spark plasma sintering process (SPS), showing much finer microstructure and higher strength than the alloys as cast. Further modification was performed by treating the surface of PM Mg specimen using Plasma electrolytic oxidation (PEO) process. During the PEO processing, MgO layer was initiated to form on the surface of Mg powder compacts, and the thickness and the density of MgO layer were varied with the reaction time. The thickening rate became low with the reaction time due to the limited diffusion rate of Mg ions. The surface morphology, corrosion behavior and wear resistance were also discussed.

Influences of Potassium Fluoride (KF) Addition on the Surface Characteristics in Plasma Electrolytic Oxidation of Marine Grade Al Alloy (해양환경용 알루미늄 합금의 플라즈마 전해 산화 시 표면 특성에 관한 불화칼륨(KF)의 영향)

  • Lee, Jung-Hyung;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.3
    • /
    • pp.280-285
    • /
    • 2016
  • In this study, we investigated the influences of potassium fluoride(KF) addition on the surface characteristics of plasma electrolytic oxidation(PEO) coating produced on Al alloy. The PEO of marine grade Al alloy(5083 grade) was conducted in KOH 1g/L solution adding different concentrations of KF(0, 1 and 2 g/L) under a galvanostatic regime. With KF addition, unusual behavior was observed on the voltage-time characteristic curves, which can be characterized by the following process: (i) initial rapid increase in voltage (ii) a short plateau after 1st breakdown (iii) gradual increase in voltage (iv) intermittent fluctuation of voltage after 2nd breakdown. The SEM observation revealed irregular surface morphology with KF addition, as compared with one formed without KF addition, which had a reticulate structure. The XRD analysis detected the formation of aluminium hydroxide fluoride hydrate($H_{4.76}Al_2F_{3.24}O_{3.76}$) on surface grown by PEO process with KF. Particularly, at very early stage of the process (~ 120 s), thin film was formed having nanoporous structure, and F element was confirmed on surface by EDS analysis. The thickness and surface roughness of the coating increased with increasing KF concentration. As a result, KF addition was found to be less beneficial influences on PEO of marine grade Al alloy, and therefore needs further research to improve its capability.

Characteristics of Coating Films on Hot-Dipped Aluminized Steel Formed by Plasma Electrolytic Oxidation Process at Different Current Densities (PEO 전류밀도 조건에 따른 알루미늄도금 강재상 산화코팅막의 특성)

  • Choi, In-Hye;Lee, Hoon-Seung;Lee, Myeong-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • Plasma electrolytic oxidation(PEO) has attracted attention as a surface treatment which has high wear resistance and corrosion resistance. PEO is generally considered as cost-effective, environmentally friendly and superior in terms of coating performance. Most of studies about the PEO processes have been applied to light metals such as Al and Mg. Because the strength of Al and Mg is weaker than that of steel, there is a limit to the application. In this study, PEO process was used to form oxide coatings on Hot dipped aluminized(HDA) steel and the characteristics of the coating film according to the PEO current density were studied. The morphology was observed by SEM and component was analyzed by using EDS. The corrosion behaviors of PEO coating films were estimated by exposing salt spray test at 5 wt.% NaCl solution and measuring polarization curves in deaerated 3 wt.% NaCl solution. With the increase of PEO process current density, the pore size of the coating surface and the thickness of coating increased. It was confirmed that no Fe component was present on the coating surface. PEO coating films obviously showed good corrosion resistance compared with HDA. It is considered that the PEO coating acts as a barrier to protect the base material from external factors causing corrosion.

Composite PEO-Coatings as Defence Against Corrosion and Wear: A Review

  • Gnedenkov, S.V.;Sinebryukhov, S.L.;Sergienko, V.I.;Gnedenkov, A.S.
    • Corrosion Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.212-219
    • /
    • 2019
  • This paper reviews recent approaches to develop composite polymer-containing coatings by plasma electrolytic oxidation (PEO) using various low-molecular fractions of superdispersed polytetrafluoroethylene (SPTFE). The features of the unique approaches to form the composite polymer-containing coating on the surface of MA8 magnesium alloy were summarized. Improvement in the corrosion and tribological behavior of the polymer-containing coating can be attributed to the morphology and insulating properties of the surface layers and solid lubrication effect of the SPTFE particles. Such multifunctional coatings have high corrosion resistance ($R_p=3.0{\times}10^7{\Omega}cm^2$) and low friction coefficient (0.13) under dry wear conditions. The effect of dispersity and ${\xi}$-potential of the nanoscale materials ($ZrO_2$ and $SiO_2$) used as electrolyte components for the plasma electrolytic oxidation on the composition and properties of the coatings was investigated. Improvement in the protective properties of the coatings with the incorporated nanoparticles was explained by the greater thickness of the protective layer, relatively low porosity, and the presence of narrow non-through pores. The impedance modulus measured at low frequency for the zirconia-containing layer (${\mid}Z{\mid}_{f=0.01Hz}=1.8{\times}10^6{\Omega}{\cdot}cm^2$) was more than one order of magnitude higher than that of the PEO-coating formed in the nanoparticles-free electrolyte (${\mid}Z{\mid}_{f=0.01Hz}=5.4{\times}10^4{\Omega}{\cdot}cm^2$).

Process Parameter Selection for Plasma Electrolytic Oxidation to Improve Heat Dissipation Performance of Aluminum Alloy Heat Sink for Shipboard LED Luminaries (선박용 LED 등기구의 알루미늄 합금 방열판의 방열성능 향상을 위한 플라즈마 전해 산화의 공정변수 선정에 관한 연구)

  • Lee, Jung-Hyung;Jeong, In-Kyo;Han, Min-Su
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.6
    • /
    • pp.415-420
    • /
    • 2018
  • The possibility of an improvement in heat dissipation performance of aluminum alloy heat sink for shipboard LED luminaries through plasma electrolytic oxidation (PEO) was investigated. Four different PEO coatings were produced on aluminum alloy 5052 in silicate based alkaline solution by varying current density ($50{\sim}200mA/cm^2$). On voltage-time response curves, three stages were clearly distinguished at all current densities, namely an initial linear increase, slowdown of increase rate, and steady state(constant voltage). It was found that the increase in current density caused the breakdown voltage to increase. Two different surface morphologies - coralline porous structure and pancake structure - were confirmed by SEM examination. The coralline porous structure was predominant in the coatings produced at lower current densities (50 and $100mA/cm^2$) while under high current densities(150 and $200mA/cm^2$) the pancake structure became dominant. The coating thickness was measured and found to be in a range between about $13{\mu}m$ and $44{\mu}m$, showing increasing thickness with increasing current density. As a result, $100mA/cm^2$ was proposed as an effective process parameter to improve the heat dissipation performance of aluminum alloy heat sink, which could lower the LED operating temperature by about 30%.

Effective Electrolytic Water Generation Characteristics by Overlapped Multi-layer Electrode (중첩형 다단전극에 의한 효율적인 전해 이온수 발생 특성)

  • Shin, Dong-Hwa;Hwang, Deok-Hyun;Jung, Jae-Seung;Kim, Hyung-Pyo;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.59-64
    • /
    • 2016
  • Applications of electrolytic ion water generated by the oxidation-reduction have gradually been expanded due to their strong sterilizing power and a surface active force. We demonstrate the effect of the multi-layer type electrode for effective ion water generation. The multi-layer type electrode has ability to generate stronger acid and alkali water by increase of the electrode reactive area. Also power consumption efficiency enhances because the electrodes disposed in middle position of the reactive cell raise the usage rate by overlapped effect as an electrolysis electrode.