• 제목/요약/키워드: Electrolysis Reactor

검색결과 54건 처리시간 0.027초

알루미늄부식을 조합한 간헐폭기법에 의한 합성폐수 중의 인 및 질소 제거 (Phosphorus and Nitrogen Removal from Synthetic Wastewater by Intermittently Activated Sludge combined with Aluminium Corrosion)

  • 정경훈;정오진;최형일
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.99-106
    • /
    • 2001
  • A laboratory experiment was performed to investigate phosphorus and nitrogen removal from synthetic wastewater by intermittently activated sludge process packed with aluminium plate. Three continuous experimental systems, I. e. an intermittently activated sludge process(Run A), an intermittently activated sludge process with an aluminium plate packed into the reactor(Run B), and a reactor post stage(Run C) were compared. In the batch experiments, the phosphorus removal time in the reactor packed with copper and aluminium plate simultaneously was faster than that of the reactor packed with only an aluminium plates. However, the reactor packed with only an aluminium plate could be used for phosphorus removal. Move phosphorus was removed with an increase of surface area of aluminium plate and electrolysis(NaCl) concentration. The efficiency of COD and nitrogen removal was not affected in Run B. However, the phosphrus removal efficiency decreased because of reaction products and activated sludge which gradually covered gradually the surface of the aluminium plate. The efficiency of phosphorus removal in Run C was 86.3% at the HRT of 3.2 hours. Especially, the efficiency of phosphorus removal in Run C was higher than that in Run B.

  • PDF

Design and construction of fluid-to-fluid scaled-down small modular reactor platform: As a testbed for the nuclear-based hydrogen production

  • Ji Yong Kim;Seung Chang Yoo;Joo Hyung Seo;Ji Hyun Kim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1037-1051
    • /
    • 2024
  • This paper presents the construction results and design of the UNIST Reactor Innovation platform for small modular reactors as a versatile testbed for exploring innovative technologies. The platform uses simulant fluids to simulate the thermal-hydraulic behavior of a reference small modular reactor design, allowing for cost-effective design modifications. Scaling analysis results for single and two-phase natural circulation flows are outlined based on the three-level scaling methodology. The platform's capability to simulate natural circulation behavior was validated through performance calculations using the 1-D system thermal-hydraulic code-based calculation. The strategies for evaluating cutting-edge technologies, such as the integration of a solid oxide electrolysis cell for hydrogen production into a small modular reactor, are presented. To overcome experimental limitations, the hardware-in-the-loop technique is proposed as an alternative, enabling real-time simulation of physical phenomena that cannot be implemented within the experimental facility's hardware. Overall, the proposed versatile innovation platform is expected to provide valuable insights for advancing research in the field of small modular reactors and nuclear-based hydrogen production.

철 석출장치가 결합된 무산소.호기공정에 의한 인 제거 특성 (Phosphorus Removal (Characteristics by Anoxic Oxic Process) by Anoxic and Oxic Processed Combined with Iron Electrolysis)

  • 김민호;김영규;김수복
    • 한국환경보건학회지
    • /
    • 제36권6호
    • /
    • pp.502-509
    • /
    • 2010
  • In this study, the (phosphorous removal) the characteristics of phosphorous removal due to (the iron compound precipitated) iron compound precipitation by iron electrolysis in (the anoxic. oxic process) anoxic and oxic processes (equipped with the) in an iron precipitation device were analyzed. During the device operation period, the average concentration of BOD, T-N, and T-P were 219.9 mg/l, 54.6 mg/l and 6.71 mg/l, respectively. The BOD/$COD_{Cr}$ ratio was 0.74, and the BOD/T-N and BOD/T-P ratios were 4.0 and 32.8, respectively. The removal rate of (the organic matters) organic matter (BOD and $COD_{Cr}$) was very high at 91.6% or higher, and that of nitrogen was 80.5%. The phosphorous concentration (of the final) in the treated water was 0.43 mg/l (0.05-0.74 mg/l) on average, and the removal efficiency was high at 90.8%. The soluble T-P concentrations in (an) the anoxic reactor, oxic reactor (II) and final treated water were 1.99 mg/l, 0.79 mg/l and 0.43 mg/l, respectively, which indicated that the phosphorous concentration in the treated water was very low. Regardless of the changes in the concentrations of (organic matters) organic matter, nitrogen and phosphorous in the influent, the quality of the treated water was relatively stable and high. The removal rate of T-P somewhat increased with the increase in the F/M ratio in the influent, and it also linearly increased in proportion to the T-P loading rate in the influent. In the treatment process used in this study, phosphorous was removed (using) by the precipitated iron oxide. Therefore, the consumption of organic (matters) matter for biological phosphorus removal was minimized and (most of the organic matters were) was mostly used as the organic carbon source for the denitrification in the anoxic reactor. This (can be an economic) treatment process (without the need for the supply of additional organic matters) is economic and does not require the supply of additional organic matter.

철 석출장치에 의한 폐수 중의 인 제거 특성 (Characterization of Phosphorus Removal in Wastewater Using Iron Precipitation Reactor)

  • 조일형;조경덕;안상우;장순웅;김영규
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.89-95
    • /
    • 2006
  • This study was conducted to improve an effect of phosphorus removal using FNR(Ferrous Nutrient Removal) process which had iron precipitation reactor and to analyze the iron corrosion. For simultaneous removal of phosphorus, iron electrolysis was combined with oxic tank. In this study, The removal efficiency of phosphorus increased with an increase voltage in iron precipitation reactor. The distance of 15mm between the two iron bed in each tests influence the concentration of remaining phosphorus most. The extensive surface area of iron bed is the more removes the phosphorus. In this test the $400\;cm^2$ of surface area was proved to be the most removal efficient.

수중 플라즈마 공정을 이용한 Rhodamine B 염료의 제거 (Removal of Rhodamine B Dye Using a Water Plasma Process)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제37권3호
    • /
    • pp.218-225
    • /
    • 2011
  • Objectives: In this paper, a dielectric barrier discharge (DBD) plasma reactor was investigated for degrading the dye Rhodamine B (RhB) in aqueous solutions. Methods: The DBD plasma reactor system in this study consisted of a plasma component [titanium discharge (inner), ground (outer) electrode and quartz dielectric tube], power source, and gas supply. The effects of various parameters such as first voltage (input power), gas flow rate, second voltage (output power), conductivity and pH were investigated. Results: Experimental results showed that a 99% aqueous solution of 20 mg/l Rhodamine B is decolorized following an eleven minute plasma treatment. When comparing the performance of electrolysis and plasma treatment, the RhB degradation of the plasma process was higher that of the electrolysis. The optimum first voltage and air flow rate were 160 V (voltage of trans is 15 kV) and 3 l/min, respectively. With increased second voltage (4 kV to 15 kV), RhB degradation was increased. The higher the pH and the lower conductivity, the more Rhodamine B degradation was observed. Conclusions: OH radical generation of dielectric plasma process was identified by degradation of N, N-dimethyl-4-nitrosoaniline (RNO, indicator of OH radical generation). It was observed that the effect of UV light, which was generated as streamer discharge, on Rhodamine B degradation was not high. Rhodamine B removal was influenced by real second voltage regardless of initial first and second voltage. The effects of pH and conductivity were not high on the Rhodamine B degradation.

Electro-Fenton 반응을 이용한 유독성 유기화합물 처리 (Removal of Toxic Organic Compound using Electro-Fenton Reaction)

  • 박상원
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.551-560
    • /
    • 2004
  • The feasibility and efficiency of the hydrogen peroxide produced by an electrolysis cell reactor was investigated, From regulating voltages for the given reaction time, the concentration of the hydrogen peroxide was gradually increased with increasing voltages. Optimal voltage range was found to be 10~15 V. The concentration of hydrogen peroxide was much higher with oxygen gas than without oxygen gas in the cathodic chamber. But there was a little difference in the generating rate of hydrogen peroxide regardless of the presence of nitrogen gas. Under given conditions, the maximum value of ICE(Instantaneous Current Efficiency) was about 38%, and then current density was 74 $mA/\textrm{cm}^2.$ The specific energy consumption was $0.694[kWh/kg-H_2O_2].$ Since Esp (Specific Energy Consumption)was very little value, It did not demand high energy in this system. Using the hydrogen peroxide gained in the experiment, Fenton's reaction was conducted and the removal of nitrobenzene, 3-chlorophenol and dye wastewater was studied. This results were very similar to the Fenton's reaction by using commercial hydrogen peroxide.

전기분해수 살균효과 및 소독부산물 생성 특성 평가 (Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water)

  • 조영만
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

선박평형수 처리를 위한 전기화학 반응에서 음극의 영향 (Effect of Cathode in Electrochemical Reaction for Treating Ballast Water)

  • 김동석;박혜진;윤종문;박용석;박영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1175-1182
    • /
    • 2014
  • In this study, we examined the effect of cathode from electrolysis reactor for treating ballast water. We are going to select a suitable cathode for seawater electrolysis after considering the effect on the generation of the oxidant of cathode and the electrode deposition materials adhering to the surface of cathode. Anode is Ru-Ti-Pd electrode and cathode are Ti, Pt, JP520 (Ni-Pt-Ce) electrodes. Using the cathode of the three types, experiments were conducted to examine the effects of TRO (total residual oxidants) generation concentration and RNO (N, N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation concentration (in 1, 35 psu), ohmic drop, FESEM(field emission scanning electron microscope) observation of cathode surface and EDX (energy dispersive X-ray spectroscopy) measurements of attached fouling material. The results showed that TRO generation concentration and RNO degradation concentration in according to each type of cathode are not different. The attached fouling materials were observed on the surface of Ti and the JP520 electrode by the observation of SEM after electrolysis for two hours, but it was not observed on the surface of Pt electrode. When considering the surface ohmic drop of cathode and the attached fouling materials, Pt electrode was judged as the excellent cathode.

전기분해에 의한 하수슬러지 가용 효과 연구 (Study on solubilization of sewage sludge using electrolysis techniques)

  • 이지선;장인성;이철구;정선용
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.979-984
    • /
    • 2011
  • 지속적인 하수처리장 증설에 따른 하수 슬러지 발생량이 증가하고 있으나, 런던협약 발효에 의해 2012년부터 해양투기가 금지되어서 효과적인 슬러지 감량화 및 처분에 대한 기술 수요가 꾸준히 제기되고 있다. 따라서 본 연구에서는 슬러지 처분법의 대안으로 전기분해를 활용한 슬러지 가용화 연구를 수행하였다. 전극은 티타늄 (Titanium)에 이리듐 (Iridium)을 코팅한 불용성 전극을 사용하여 직류전원 공급장치 (DC power supply)를 이용하였다. 전압은 20V로 고정하여 폐슬러지 가용화 실험을 수행하였다. 전기분해에 의해 처리된 슬러지의 여액을 분석한 결과 Soluble COD, TN, TP가 각각 151%, 22%, 6% 가량 증가하였다. 또한, 슬러지의 플록 크기가 전기분해 후에 0.1 ~ 1.0 ${\mu}m$ 영역에 있는 입자들이 다량 증가하였다. 이상의 결과는 전기분해에 의하여 미생물 세포가 파괴되어 세포 내 유기물질이 세포 밖으로 용출됨으로써 미생물이 이용 가능한 상태로 전환되었음을 의미한다. 이는 고도처리 공정에서 슬러지발생 저감과 함께 전기분해에 의해 가용화된 슬러지를 반송시킴으로써 외부 탄소원으로 활용할 수 있는 장점이 있다.

조류제거를 위한 구리이온 발생 반응기의 특성 연구 (A Study on the Characteristics of Copper Ion Generator for the Removal of Algae)

  • 이선영;김혜연;주재백
    • 전기화학회지
    • /
    • 제15권1호
    • /
    • pp.41-47
    • /
    • 2012
  • 조류제거를 위한 구리이온을 생성하기 위한 환형 흐름 구리 전기분해 반응기 시스템을 구성하고 그 가동특성에 대하여 고찰하였다. 또한 구리이온이 조류에 미치는 영향도 살펴보았다. 인가전류를 증가하면 균등조로부터 배출되는 구리 이온 농도가 비례적으로 증가함을 알 수 있었다. 전류 밀도를 조절하여 원하는 구리농도를 얻을 수 있음을 알았으며 패러데이 효율은 90% 이상임을 알 수 있었다. 유량을 증가시키면 구리이온농도는 감소하였으며 이는 전극에서의 반응속도와는 상관없이 물의 증가량에 따른 희석 때문임을 알 수 있었으며 농도 과전위 영향은 미미하였다. pH가 증가할수록 생성되는 구리이온 농도는 이에 반비례하여 감소하였고 전기전도도의 변화는 배출되는 구리이온 농도에 별 영향을 미치지 않았다. 구리이온 농도가 증가시킬 경우 Chlorophyll-a 농도가 크게 감소함을 볼 수 있으며, 구리 이온 농도가 0.2 ppm 이상일 때 조류가 효과적으로 제거됨을 알 수 있다. 황산구리를 용해시킨 구리이온이나 전기분해를 통해 얻은 구리이온을 투여한 경우 별차이가 없었으며 5일 후 조류 제거효율은 0.4 ppm이상의 농도에서는 90%이상이었다.