• Title/Summary/Keyword: Electrode treatment

Search Result 698, Processing Time 0.033 seconds

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF

Effects of Traditional Acupuncture on Colonic Motility in the Rat with Colitis (결장염 유발 Rat의 결장운동성에 침술이 미치는 영향)

  • Kim, Hee-Young;Shim, In-Sop;Lee, Hye-Jung;Jeong, Seong-Mok;Kim, Sun-Young;Nam, Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.22-25
    • /
    • 2003
  • The aims of this study were to investigate the efficacy of acupuncture on myoelectrical activity of inflamed or normal colon in the rat, and whether the effect of acupuncture on colonic motility was related to endogenous opioids. Twenty-two male Sprague-Dawley rats were divided into three groups. Experimental groups were normal group (n = 8), colitis group (n = 6) and naloxone group (n = 8). Stainless steel bipolar electrodes were implanted on the serosal layer of the proximal colon of rats. Colitis was induced 7 days after electrode implantation using trinitrobenzene sulphonic acid (TNBS) and ethanol. Electromyograms (EMG) were recorded by using polygraph 11 days after implantation of electrodes. In normal group, normal colonic motility was recorded for 60 min, and then traditional acupuncture at GV-1 was applied for 20 min and EMG was recorded for further 60 min in untreated rats. In colitis group, after recording of basal colonic motility for 60 min, 20 min of acupuncture treatment and further EMG recording was performed for 60 min in TNBS/ethanol treated rats. In naloxone group, following subcutaneous administration of naloxone (3 mg/kg), recording of EMG and acupuncture treatment were performed in TNBS/ethanol treated rats. In the normal group, acupuncture at GV-1 did not induce significant changes in colonic motility. TNBS/ethanol treatment had no significant effect on the frequency of colonic motility. And in colitis group, GV-1 acupuncture significantly decreased colonic motility (p < 0.01). In naloxone group, after injection of naloxone, acupuncture at GV-1 did not change colonic motility in TNBS/ethanol treated rats. On the inflamed colon, naloxone blocked the effect of acupuncture. The present results suggested that endogenous opioids released by acupuncture at GV-1 decrease the motility of inflamed colon in rats, but not normal colon.

Performance of Upflow Anaerobic Bioelectrochemical Reactor Compared to the Sludge Blanket Reactor for Acidic Distillery Wastewater Treatment (상향류식 혐기성 슬러지 블랭킷 반응조에 비교한 생물전기화학 반응조의 산성 주정폐수처리성능)

  • Feng, Qing;Song, Young-Chae;Yoo, Kyuseon;Lal, Banwari;Kuppanan, Nanthakumar;Subudhi, Sanjukta
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.279-290
    • /
    • 2016
  • The performance of upflow anaerobic bioelectrochemical reactor (UABE), equipped with electrodes (anode and cathode) inside the upflow anaerobic reactor, was compared to that of upflow anaerobic sludge blanket (UASB) reactor for the treatment of acidic distillery wastewater. The UASB was stable in pH, alkalinity and VFAs until the organic loading rate (OLR) of 4.0 g COD/L.d, but it became unstable over 4.0 g COD/L.d. As a response to the abrupt doubling in OLR, the perturbation in the state variables for the UABE was smaller, compared to the UASB, and quickly recovered. The UABE stability was better than the UASB at higher OLR of 4.0-8.0 g COD/L.d, and the UABE showed better performance in specific methane production rate (2,076mL $CH_4/L.d$), methane content in biogas (66.8%), and COD removal efficiency (82.3%) at 8.0 g COD/L.d than the UASB. The maximum methane yield in UABE was about 407mL/g $COD_r$ at 4.0 g COD/L.d, which was considerably higher than about $282mL/g\;COD_r$ in UASB. The rate limiting step for the bioelectrochemical reaction in UABE was the oxidation of organic matter on the anode surface, and the electrode reactions were considerably affected by the pH at 8.0 g COD/L.d of high OLR. The maximum energy efficiency of UABE was 99.5%, at 4.0 g COD/L.d of OLR. The UABE can be an advanced high rate anaerobic process for the treatment of acidic distillery wastewater.

Interface Control to get Higher Efficiency in a-Si:H Solar Cell

  • Han, Seung-Hee;Kim, En-Kyeom;Park, Won-Woong;Moon, Sun-Woo;Kim, Kyung-Hun;Kim, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.193-193
    • /
    • 2012
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is the most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. Single-chamber PECVD system for a-Si:H solar cell manufacturing has the advantage of lower initial investment and maintenance cost for the equipment. However, in single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of single-chamber PECVD system. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. In order to remove the deposited B inside of the plasma chamber during p-layer deposition, a high RF power was applied right after p-layer deposition with SiH4 gas off, which is then followed by i-layer, n-layer, and Ag top-electrode deposition without vacuum break. In addition to the p-i interface control, various interface control techniques such as FTO-glass pre-annealing in O2 environment to further reduce sheet resistance of FTO-glass, thin layer of TiO2 deposition to prevent H2 plasma reduction of FTO layer, and hydrogen plasma treatment prior to n-layer deposition, etc. were developed. The best initial solar cell efficiency using single-chamber PECVD system of 10.5% for test cell area of 0.2 $cm^2$ could be achieved by adopting various interface control methods.

  • PDF

Sensitivity Measurement of the Piezoelectric Paint Sensor according to the Poling Electric Field (분극 전계에 따른 압전 페인트 센서 감도 측정)

  • Han, Dae-Hyun;Park, Seung-Bok;Kang, Lae-Hyong
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.146-151
    • /
    • 2014
  • In this study, the experimental study has been performed by varying the polarization of the electric field and impact force to check the piezoelectric characteristics of piezoelectric paint sensor. Piezoelectric paint sensor used in this study is composed of epoxy resin with a hardener and PNN-PZT powder in 1:1 weight ratio. The dimensions of the paint sensor specimen are $40{\times}40{\times}1mm^3$ and regular specimens were made using a mold. The voids are removed from the specimen in the vacuum desiccator. Both upper side and bottom side of the paint sensor were coated with silver paste for making an electrode and then dried at room temperature for a day. The poling treatment has been carried out under controlled conditions of the electric field in order to check the effect of piezoelectric sensitivities, while the poling temperature was fixed at room temperature and the poling time was set to 30 min. The piezoelectric sensitivities have been measured by comparing output voltage from paint sensor with output force from impact hammer when the impact hammer hits the paint sensor. In result, the effect of the electric field has been evaluated for the sensitivity and describe the result.

Oxygen Reduction of PAFC Gas Diffusion Electrode with Various Pt Impregnation Methods (인산형 연료전지용 기체확산전극의 백금촉매 담지방법에 따른 산소환원 특성)

  • Yoo, Duck-Young;Eun, Yeong-Chan;Shim, Joong-Pyo;Lee, Ju-Seong
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.999-1005
    • /
    • 1996
  • Pt catalyst on carbon black was prepared by colloidal method, ion exchanging method and methanol reducing method. The colloidal method has been used generally. At ion exchanging method, $H^+$ of functional group on carbon surface made by oxidation treatment was exchanged with Pt ion. At methanol reducing method, Pt was impregnated on carbon to reduce by methanol contained with surfactants. With TEM and XRD, Pt particle size impregnated on carbon by various methods was $30{\sim}50{\AA}$. Loading yield was about 100%, loading yield of ion exchanging method was 99.92% by DCP analysis and 99.87% by combustion method. Within 60 hour, current density of oxygen reduction was $460mA/cm^2$ at 0.7V(vs. RHE) at colloidal method. It was the better performance than catalyst prepared by ion exchanging, methanol reducing method. But, it was shown some decrease of performance for long operation time(after 100hour), catalyst prepared by methanol reducing method was shown stable performance.

  • PDF

Effect of Sojukgunbihwan granule on Gastric Motility in Rats (소적건비환과립(消積健脾丸顆粒)이 흰쥐의 위운동성(胃運動性)에 미치는 영향)

  • Hong, Jong-Hee;Kim, Jin-Sung;Ryu, Bong-Ha;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.1
    • /
    • pp.276-287
    • /
    • 2006
  • Background & Objective : The herbal medicine Sojukgunbihwan granule has been used for the treatment of functional dyspepsia, generally categorized as a gastric dysmotility disease. However, its mechanisms are not yet well known. Therefore, the effects of Sojukgunbihwan granules on gastric motility in rats was investigated. Methods : The myoelectrical activity of the gastric smooth muscle was recorded by a bipolar electrode placed at the gastric antrum of rats. The contractile waves were measured for 30 minutes before and after intragastric administration of each solution(normal saline, Pyungwisan 40mg/kg, Sojukgunbihwan granules 60mg/kg) and expressed as the motility index. Gastric emptying was measured by the number of glass beads expelled from the stomach(containing one hundred 1mm glass beads) within an hour after glass beads and test drugs(normal saline, Pyungwisan 40mg/kg, Pyungwisan 120mg/kg, Sojukgunbihwan granules 60mg/kg, Sojukgunbihwan granules 180mg/kg) were administered. In another series of experiments to evaluate the mechanisms of Sojukgunbihwan granules under delayed conditions, the rats were treated with atropine sulfate(1 mg/kg, s.c.), cisplatin(10mg/kg, i.p.), and NAME($N^G$-nitro-L-arginine methyl ester, 75mg/kg, s.c.) respectively. Results : Intragastric administration of Sojukgunbihwan granules increased the myoelectrical activity significantly, gastric motility index rose 25%, and gastric emptying of glass beads was significantly enhanced over a period of 60minutes. Under the delayed gastric emptying induced by atropine sulfate, cisplatin, and NAME, Sojukgunbihwan granules aggravated gastric emptying in the atropine sulfate($5.71{\pm}3.45\;vs\;3.71{\pm}4.42$) and cisplatin($13.86{\pm}3.53\;vs\;5.14{\pm}5.05$, p<0.01) treated groups, but enhanced gastric emptying in the NAME treated group($5.00{\pm}3.21\;vs\;11.71{\pm}5.65$, p<0.05). Conclusions : Results suggest that Sojukgunbihwan granules stimulate gastric motility through cholinergic and 5-hydroxytryptamine 3 receptors. Results are indicative of Sojukgunbihwan as an especially effective remedy in dysmotility-like functional dyspepsia with impaired reservoir functions such as gastric adaptive relaxation.

  • PDF

Synthesis of Mg2Ni by mechanical alloying and its electrochemical characteristics for Ni-MH secondary battery (Ni-MH 2차 전지용 Mg2Ni의 기계적 합금화법에 의한 제조 및 전기화학적 특성)

  • Moon, Hong-Gi;Choi, Seung-Jun;Kim, Dae-Hwan;Park, Choong-Nyeon
    • Journal of Hydrogen and New Energy
    • /
    • v.10 no.4
    • /
    • pp.225-232
    • /
    • 1999
  • The $Mg_2Ni$ hydrogen storage alloys which have much higher theoretical discharge capacity than $AB_5$ and $AB_2$ type alloys were synthesized by mechanical alloying with some additives and subjected to the electrochemical measurements. Two different processes were employed to the synthesis of $Mg_2Ni$ alloys with using the high energy ball mill SPEX 8000. One was only ball milling, 12 hrs, the Mg and Ni powders for 12 hrs with additives such as $AB_5$, Ni, Co and Cu powders. In the other process the Mg and Ni powders were ball milled for 1 hr first and then heat treated at $300{\sim}400^{\circ}C$ for 1 hr to get $Mg_2Ni$ alloy, and finally the $Mg_2Ni$ alloy powders were ball milled with the additives for 12 hrs. The alloy powders prepared were compacted at room temperature under $7.64tons/cm^2$ into disk type electrodes for the electrochemical measurements. The experimntal results showed that the electrodes prepared with the heat treated alloy powders had a higher discharge capacities than those without heat treatment. The addition of Ni caused an increase of the discharge capacity and the addition of Co improved the cycling characteristics. The electrode prepared by ball milling of $Mg_2Ni$ and 10wt% Ni powders has showed the highest discharge capacity, 546mAh/g.alloy, which was 55% of the theoretical capacity.

  • PDF

Selective Oxidation of 2,6-di-tert-butylphenol by Oxygen Adducted Pentadentate Schiff Base Cobalt (Ⅱ) Activated Catalysts and Electrochemical Properties of Cobalt (Ⅱ) Catalysts in Aprotic Solvents (비수용매에서 산소첨가된 다섯자리 Schiff Base Cobalt (Ⅱ) 활성촉매들에 의한 2,6-di-tert-butylphenol의 선택산화와 전기화학적 성질)

  • Chjo, Ki-Hyung;Choi, Yong-Kook;Kim, Sang-Bock;Lee, Song-Ju;Kim, Jong-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.689-698
    • /
    • 1991
  • Activated oxidation catalysts are generated by the treatment of pentadentate Schiff base cobalt(Ⅱ) complexes with the oxygen saturated DMF solution. Oxidation of 2,6-di-tert-butylphenol by homogeneous oxidation catalysts of superoxo type pentadentate schiff base cobalt(Ⅲ) complexes yields 2,6-di-tert-butylbenzoquinone(BQ) as a major product. And $O_2$/Co mole ratio of homogeneous oxidative catalysts such as [Co(Ⅲ)(sal-DET)]$O_2$ and [Co(Ⅲ)(sal-DPT)]$O_2$by PVT method of the oxygen absorption in DMSO and pyridine solution was 1:1, 1:1.52 in DMF solution and ${\mu}$-peroxo type cobalt(Ⅲ) complexes formed at solid state. The redox reaction processes of superoxo type cobalt(Ⅲ) complexes as homogeneous oxidation catalysts were investigated by cyclic voltammetry and DPP method at a glassy carbon electrode. As a result of electrochemical measurements the reduction processes of oxygen adducted superoxo type cobalt(Ⅲ) complexes occurred to four steps including prewave of $O_2$-in 0.1M TEAP-DMSO and 0.1 M TEAP-Pyridine as supporting electrolyte solution.

  • PDF

Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator (이온수기 필터(pH)의 안정화 성능평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. And there are various types of water. Ionic water generator is a system with special function, and can be classified as a medical device and should be manufactured after approval from the Food and Drug Administration. Basically ionized water is different from the packaged and stored water. When the tap water or ground water passes through the various filters of ionic water generator, it turns to the purified water of pH7 ~ 7.5 and we can electrolyze that water into anion and cation by diaphragm. And in negative electrode side, we can get alkaline water with calcium ($Ca^+$), potassium ($K^+$), magnesium ($Mg^+$), sodium ($Na^+$) for body. In general, we can change pH value from 5 to 9 of ionizer by controlling the level of electrolysis voltage in the ionizer. In general, 1stage (pH8), 2stage (pH8.5), 3stage (pH9), 4stage (pH9.5) are used as the alkaline ionized water, -1Stage (pH6.0), -2 stage (pH5.0) are used as the acidic water. But in early stage, the water that passed through filter was weakly alkaline water and that was problem. Therefore, when filter condition is stable, the pH and ORP value of water is different with the early one. the initial setting pH value of the ionizer was confirmed that changes significantly. In order to resolve this problem we need to wash filter for some period time and neutralize by acidification treatment of the filter.