• 제목/요약/키워드: Electrode configuration

검색결과 196건 처리시간 0.023초

라미네이팅 필름의 코로나 처리 효과와 주사 전자현미경을 이용한 해석 (The Effect of Corona Treated on Laminating Film and Its Analytical Study by SEM)

  • 김종규;김양평
    • 한국인쇄학회지
    • /
    • 제26권2호
    • /
    • pp.15-30
    • /
    • 2008
  • Studies were carried out the phenomenal observation on the effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of experiments. These are as follow: 1) In order to verify the treatment reducing value of dynes and dynes durability with the lapse of time, it was checked dynes of a pair of 4 bar discharge electrode with 9 one for 144 hr., and it show results that 9 bar discharge electrode has higher initial dynes as well as keep up 48 dynes durability long than 4 one. 2) Drawn an inference from 3 actions -Chemical-Physical-Mechanical, on laminating film in terms of SEM's observation that are the adhesive status in boundary of corona treated base film, extrusion coating hotmelt layer, and configuration of hotmelt surface after corona treated. In tandem system, EVA layers adhesion keep its stability without corona discharge treatment.

  • PDF

XPS Study of MoO3 Interlayer Between Aluminum Electrode and Inkjet-Printed Zinc Tin Oxide for Thin-Film Transistor

  • Choi, Woon-Seop
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.267-270
    • /
    • 2011
  • In the process of inkjet-printed zinc tin oxide thin-film transistor, the effect of metallic interlayer underneath of source and drain electrode was investigated. The reason for the improved electrical properties with thin molybdenum oxide ($MoO_3$) layer was due to the chemically intermixed state of metallic interlayer, aluminum source and drain, and oxide semiconductor together. The atomic configuration of three Mo $3d_3$ and $3d_5$ doublets, three different Al 2p core levels, two Sn $3d_5$, and four different types of oxygen O 1s in the interfaces among those layers was confirmed by X-ray photospectroscopy.

반구형 실험모델을 이용한 대지표면 전위상승의 분석 (Analysis of the Ground Surface Potential Rise using a Hemisphere-Shaped Test Model)

  • 유재덕;조용승;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.208-213
    • /
    • 2010
  • This paper deal with an analysis of the ground surface potential profiles using a hemispherical scaled-model. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the ground surface potential profile around the grounding electrodes according to the configuration of grounding electrodes. In this work, a hemispherical vessel with a diameter of 1,100 [mm] was employed to simulate uniform soil and CDEGS program was employed to compare the measured and simulated results. As a result, the ground surface potential around the grounding electrode was significantly raised and the ground surface potential at the just upper point of ground electrode particularly was higher than other points. The ground surface potential of counterpoise was higher than other grounding electrodes such as mesh and grounding rods and the ground surface potential strongly depends on the frequency responses of grounding electrodes. Also the results measured with the small-sized model were in reasonably agreement with the data obtained from simulation.

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure)

  • 박광서;신호영;최병주;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.49-55
    • /
    • 2003
  • 본 논문에서는 고온 초전도체의 냉매로서 주목받고 있는 액체질소 중에서 고체절연물 표면의 연면 방전과 트래킹 현상에 관하여 연구하였다 액체질소중 연면 방전에 많은 영향을 주는 기포 효과를 연구하기 위해 Knife형태의 전극과 평판형태의 전극을 사용하여 A-mod, B-mode, C-mode의 전극배치형태를 각각 구성하였다. 본 실험의 결과는 향후 연구되고 개발될 초전도·극저온 전력설비의 절연설계의 기초 데이터를 제공할수 있다고 판단된다.

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

$Al_{2}O_{3}$ Crystal Capacitor를 이용한 유전손실 측정 (Dielectric Loss Tangent Measurement Using the $Al_{2}O_{3}$ Crystal Capacitor)

  • 김광수;허인성;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.109-122
    • /
    • 2002
  • The standard capacitor must have not only precise value of the capacitance but also the basic properties of low dielectric loss tangent. In the reforming process of capacitors, the dielectric loss tangent must be also reformed. In this paper, the development of standard capacitors of 10 and 100pF for the dielectric loss tangent standard using $Al_{2}O_{3}$ Crystal and the measurement of dielectric loss tangent are discussed. The dielectric loss tangent depends upon the surface between electrode and dielectric in capacitor. With using the Electric Field Simulator, precise design values of electrode are simulated. For the purpose of measuring capacitance effect just in the dielectric, 3-Terminal and 4-Terminal Pair configuration are applied respectively at the electrode and the connector for the measuring equipment. As stated above method, the standard capacitors of 10 and l00pF for the establishment of the dielectric loss tangent standard using the $Al_{2}O_{3}$ Crystal are made with low dielectric loss tangent less than 10-4.

  • PDF

AZO Anode 전극을 적용한 OLED 소자의 제작과 전기적.광학적 특성 분석 (Analysis on the Electrical.optical Properties and fabrication of OLED with AZO Anode Electrode)

  • 진은미;신은철;김태완;박춘배
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.357-362
    • /
    • 2007
  • AZO(Aluminum-doped Zinc Oxide) films are attractive materials as transparent conductive electrode because they are inexpensive, nontoxic and abundant element compared with ITO(Indium Tin Oxide). AZO films have been deposited on glass (corning 1737) substrates by RF magnetron sputtering. The AZO film was post-annealed at $600^{\circ}C$ for 2 hr with $N_2$ atmosphere. The AZO films were used as an anode contact to fabricate OLEDs(Organic Light Emitting Diodes). OLEDs with $AZO/TPD/Alq_3/Al$ configuration were fabricated by thermal evaporation. We investigated that the electric, structural and optical properties of AZO thin films, which measured using the methods of XRD, SEM, Hall measurement and Spectrophotometer. The current density-voltage and luminescence-voltage properties of devices were studied and compared with ITO devices fabricated under the same conditions.

웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구 (A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements)

  • 이강휘;이성수;김상민;이혁재;민경진;강현규;이주현;곽휘권;고윤수;이정환
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

Electra-Optic Effect of Nonchiral Smectic C Liquid Crystal Mode with Negative Dielectric Anisotropy

  • Yu, Chang-Jae;Jang, Eun-Je;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.467-470
    • /
    • 2002
  • We report on an analog electro-optic effect in a nonchiral smectic C (NSC) liquid crystal (LC) mode with negative dielectric anisotropy in a transverse electrode configuration. Two-dimensional numerical simulations are executed to evaluate the display performances. The analog gray scales in the NSC LC mode are obtained in a dielectrically driving scheme.

  • PDF

와이어.이온.플라즈마원의 방전 특성 (Discharge Characteristics of Wire Ion Plasma Source)

  • 고광철;굴전영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1776-1778
    • /
    • 1997
  • WIPS is a plasma device which has a wire anode, a coaxially-set cylindrical cathode, and aperture electrodes located in both ends of the cylinder. This electrode configuration forces the potential between the anode and the cathode to change logarithmically with radial direction. Since electrons are confined this logarithmic potential, the high-density plasma is produced even at a rather low anode voltage. In this paper we investigate characteristics of dc and pulse discharges, in which

  • PDF