• Title/Summary/Keyword: Electrode configuration

Search Result 196, Processing Time 0.023 seconds

The Effect of Configuration and Surface Polishing in Tungsten Electrode Tip for Gas Tungsten Arc Welding on the Arc Characteristics (GTA용접용 텅스텐 전극팁의 형상과 연마 상태가 아크특성에 미치는 영향)

  • 조상명;서상균
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • The welding quality by Gas Tungsten Arc Welding shows very high level, but the welding speed is lower than that of gas metal arc welding. Also, the welding quality by automatic GTAW is variable as the arc characteristics is changed by the consumption of electrode tip. The purpose of this study is to investigate the relation between the properties of tungsten electrode tip and the various arc characteristics at high current region. In this study, the high welding current 200A was applied to the repeated arc start test and long term arcing test using the $\phi$3.2 tungsten electrodes with cone angle 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$sharp tip, and 60$^{\circ}$surface polished (S.P.) sharp tip. It was confirmed that the maximum arc pressure by the initial electrode condition was highest in 45$^{\circ}$sharp tip, and the next in 60$^{\circ}$sharp tip, the last was in 30$^{\circ}$sharp tip and 60$^{\circ}$S.P.. But, the maximum arc pressure after the repeated arc start test and long term arcing test was decreased considerably. But, the maximum arc pressure was highest also in 45$^{\circ}$ sharp tip after the tests, the next was in 30$^{\circ}$sharp tip, and the last was in 60$^{\circ}$sharp tip and 60$^{\circ}$S.P.. The arc start characteristics was the most excellent in 60$^{\circ}$S.P., By long term arcing test, the lanthania included in tungsten electrode was extinguished at tip surface preferentially, therefore the arc characteristics of electrode tip got worse.

  • PDF

Design of electrodes in the Patterned Vertical Aligned Liquid Crystal Cell for high optical performance (수직배향액정셀에서의 광학특성향상을 위한 전극설계)

  • Lee, Wa-Ryong;Kim, Kyung-Mi;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.344-348
    • /
    • 2007
  • In this paper, we propose the electrode of the Patterned Vertical Aligned (PVA) cell [1] for high transmittance. We use the 'TechWiz LCD' for calculation of the director configuration and optical characteristics to ensure the results of the proposed electrode structure. In general, the transmittance of the PVA cell depends on the shape of the electrode and cell gap. In this work the width of gate line and data line of the improved electrode design is set to be equal to that of the PVA conventional. Instead, we modified the shape of the top and bottom electrode on order to decrease the area of the defect. For verification, we compared the calculated optical transmittance of the PVA cell with the proposed electrode structure to the conventional PVA cell . As a result, we can confirm that the optical loss due to the variation of the retardation the LC cell around electrode can be definitely decreased by the proposed electrode.

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study

  • Song, Jun-Seop;Lee, Young-Seon;Hwang, Minki;Lee, Jung-Kee;Li, Changyong;Joung, Boyoung;Lee, Moon-Hyoung;Shim, Eun Bo;Pak, Hui-Nam
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.5
    • /
    • pp.507-514
    • /
    • 2016
  • Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in -silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: $11.5{\pm}0.7%$ variation, mini-cath: $7.1{\pm}1.2%$ variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: $r=0.3055{\pm}0.2194$ vs. mini-cath: $0.6074{\pm}0.0733$, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one ($38.3{\pm}4.6%$ vs. $22.3{\pm}1.4%$, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

Generation of Chemically Active Species in Hybrid Gas-Liquid Discharges (기체-액체 혼합 방전에 의한 화학적 활성종 생성 특성)

  • Chung, Jae-Woo;Locke, Bruce R.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.556-563
    • /
    • 2007
  • We carried out a laboratory scale experiment about the characteristics of chemically active species produced in hybrid gas-liquid discharges. The electrode configuration which had high voltage electrode in the gas phase and ground electrode in the liquid was utilized while high voltage electrode has been typically positioned in the liquid in other studies. Our electrode was configured in such a way as to increase the energy efficiency of chemical reactions by creating a higher electrical field strength and a narrower pulse width than the typical electrode configuration. The highest ozone concentration was obtained at 45 kV which was the medium value in operating voltages. The decrease of solution conductivity increased the resistance of liquid phase and the electric field strength through the gas phase, so ozone gene-ration rate was enhanced. The increase of voltage promoted the production rate of hydrogen peroxide by increasing the electric field strength. In a lower voltage, the increase of solution conductivity increased the degradation rate of $H_2O_2$, so the $H_2O_2$ generation rate decreased. On the other hand, the effects of UV radiation, shock waves etc. increased the $H_2O_2$ generation rate as the solution conductivity increased. A higher rate of $H_2O_2$ generation can be achieved by mixing argon to oxygen which generates a stronger and more stable discharges.

Corrosion Characteristics of Ti alloy for Removable Partial Denture (국소의치용 티타늄 합금의 부식 특성)

  • Kim, Jeong-Jae;Kim, Won-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.4
    • /
    • pp.237-242
    • /
    • 2014
  • In this study, surface characteristics and corrosion behaviors have been investigated in addition to Zr elements on the low elastic modulus Ti-30Ta alloy. Low elastic modulus Ti-30Ta-xZr(x : 3, 7 and 15 wt %) alloys were prepared by arc melting and then heat treated at $1000^{\circ}C$ for 24 hrs in an argon atmosphere. Microstructures of the alloys were examined by field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD). Electrochemical experiments were performed using a conventional three-electrode configuration with a sample working electrode, a high density carbon counter electrode and a saturated calomel reference electrode. According to the result of polarization behavior in the Ti-30Ta-xZr alloys, the current density of homogenized Ti-30Ta-15Zr in the passive region was lower than the other alloys.

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance (생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

Fabrication and Characterization of Organic Thin-Film Transistors by Using Polymer Gate Electrode (고분자 게이트 전극을 이용한 유기박막 트랜지스터의 제조 및 소자성능에 관한 연구)

  • Jang, Hyun-Seok;Song, Ki-Gook;Kim, Sung-Hyun
    • Polymer(Korea)
    • /
    • v.35 no.4
    • /
    • pp.370-374
    • /
    • 2011
  • A conductive PANI solution was successfully fabricated by doping with camphorsulfonic acid and the polymerization of aniline and the confirmation of doping were characterized by FTIR spectroscopy. In organic thin film transistors, PANI gate electrodes were spin-coated on a PES substrate and their conductivity variations were monitored by a 4-probe method with different annealing temperatures. The surface properties of PANI thin films were investigated by an AFM and an optical microscope, OTFTs with PANI gate electrode had characteristics of carrier mobility as large as 0.15 $cm^2$/Vs and on/off ratio of $2.4{\times}10^6$, Au gate OTFTs with the same configuration were fabricated to investigate the effect of polymer gate electrode for the comparison of device performances. We could obtain the comparable performances of PANI devices to those of Au gate devices, resulting in an excellent alternative as an electrode in flexible OTFTs instead of an expensive Au electrode.