• Title/Summary/Keyword: Electrode Model

Search Result 522, Processing Time 0.029 seconds

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

Numerical Simulation of Normal Logging Measurements in the Proximity of Earth Surface (지표 부근에서의 노멀전기검층 수치 모델링)

  • Nam, Myung-Jin;Hwang, Se-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.3
    • /
    • pp.259-267
    • /
    • 2010
  • Resistivity logging instruments were designed to measure electrical resistivity of formation, which can be directly interpreted to provide water-saturation profile. Short and long normal logging measurements are made under groundwater level. In some investigation sites, groundwater level reaches to a depth of a few meters. It has come to attention that the proximity of groundwater level might distort short and long normal logging readings, when the measurements are made near groundwater level, owing to the proximity of an insulating air. This study investigates the effects of the proximity of groundwater level (and also the proximity of earth surface) on the normal by simulating normal logging measurements near groundwater level. In the simulation, we consider all the details of real logging situation, i.e., the presence of wellbore, the tool mandrel with current and potential electrodes, and currentreturn and reference-potential electrodes. We also model the air to include the earth’'s surface in the simulation rather than the customary choice of imposing a boundary condition. To obtain apparent resistivity, we compute the voltage, i.e., potential difference between monitoring and reference electrodes. For the simulation, we use a twodimensional, goal-oriented and high-order self-adaptive hp finite element refinement strategy (h denotes the element size and p the polynomial order of approximation within each element) to obtain accurate simulation results. Numerical results indicate that distortion on the normal logging is greater when the reference potential electrode is closer to the borehole and distortions on long normal logging are larger than those on short normal logging.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

Subsurtace Geological Structure of the Downstream Area of the Jangsung Lake (장성호 하류지역의 지하지질구조)

  • 김성균;김용준;오진용;김민선;서구원
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.101-112
    • /
    • 1997
  • Gravity and electrical resistivity surveys were carried out across the Kwangju fault in the downstream area of the Jangsung Lake, to investigate the location and geometrical feature of the fault. In the resistivity survey, dipole - dipole array method was adopted for 3 survey lines of which length and electrode spacing are 500m and 25m, respectively. Resistivity data are interpreted with aid of computer program "RESIS" which is widely used in resistivity data analysis and two dimensional resistivity profiles are obtained for 3 survey lines. Two large fracture zones relevant to the Kwangju fault are identified in the resistivity profiles. The total of 80 gravity data are observed with the mean spacing of 40 m and the exact leveling is accompanied to obtain more precise gravity anomalies. The subterranean density discontinuities calculated from the inverse method are appeared at the depths of 650rn and 120m. It is considered that the deep discontinuity indicates boundary between Jurassic granites and oveflying Cretaceous tuff formation. while, the shallow discontinuity is interpreted to be a boundary between alluvial deposits and basements. The subsurface geological structure to satisfy the observed Bouguer anomaly is determined from the iterative forward method in which results from existing surface geological informations, the inverse method, and from the resistivity interpretations are employed as an iuitial model. In conclusion, Kwangju fault is appeared to be a high angle normal fault mainly formed in tension stress filed.

  • PDF

Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method (전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지)

  • 김형수
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.139-149
    • /
    • 1997
  • Electrical resistivity monitoring methods were adopted to detect groundwater table change in alluvium. Numerical modelling test using finite element method(FEM) and field resisfivity monitoring were conducted in the study. The field monitoring data were acquired in the alluvium deposit site in Jeong-Dong Ri, Geum River where pumping test had been conducted continuously for 20 days to make artificial changes of groundwater table. The unit distance of the electrode array was 4m and 21 fixed electrodes were applied in numerical calculation and field data acquisition. "Modified Wenner" and dipole-dipole array configurations were used in the study. The models used in two-dimensional numerical test were designed on the basis of the simplifving geological model of the alluvium in Jeong Dong Ri, Geum River. Numerical test results show that the apparent resistivity pseudosections were changed in the vicinity of the pootion where groundwater table was changed. Furthermore, there are some apparent resistivity changes in the boundary between aquifer and crystalline basement rock which overlays the aquifer. The field monitoring data also give similar results which were observed in numerical tests. From the numerical test using FEM and field resistivity monitoring observations in alluvium site of Geum River, the electrical monitoring method is proved to be a useful tool for detecting groundwater behavior including groundwater table change. There are some limitations, however, in the application of the resistivity method only because the change of groundwater table does not give enough variations in the apparent resistivity pseudosections to estimate the amount of groundwater table change. For the improved detection of groundwater table changes, it is desirable to combine the resistivity method with other geophysical methods that reveal the underground image such as high-resolution seismic and/or ground penetrating radar surveys.

  • PDF

PRIDE 3D Simulator for Virtual Verification of Remote Handling Procedures in Processing Cell (PRIDE 3D 시뮬레이터를 통한 공정셀 내부의 원격작업 가상검증)

  • Ryu, Dongseok;Han, Jonghui;Kim, Sunghyun;Kim, Kiho;Lee, Jong Kwang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.333-341
    • /
    • 2017
  • The Korea Atomic Energy Research Institute (KAERI) constructed the PyRoprocessing Integrated inactive Demonstration facility (PRIDE) to carry out experiments on engineering scale pyroprocessing. PRIDE has a large processing cell that human workers are not allowed to access, and thus the equipment inside is operated from outside using remote handling systems. It is therefore essential to examine the operability and maintainability of the equipment in view of remote handling systems, and the equipment is thoroughly examined in a mockup cell before it is installed in the processing cell. If the equipment is tested in a virtual mockup rather than in a mockup cell, the development cost can be significantly reduced. The PRIDE 3D simulator was integrated for virtual verification of equipment that will be installed in the processing cell. All remote handling devices in the actual PRIDE were also virtually installed in the PRIDE 3D simulator. The 3D model of the equipment was loaded and located in the exact position in the virtual processing cell. A scenario to replace an actual electrode was implemented in the PRIDE 3D simulator. The design of the equipment and the working procedures in the scenario were successfully evaluated. The results demonstrated that the PRIDE 3D simulator can be used successfully as an alternative to actual mockup testing.

The Effects of Acupuncture on the Electroencephalogram of Patients with Stroke (자침이 중풍환자의 뇌파 변화에 미치는 영향)

  • Yoon, Ga-Young;Park, Ji-Min;Kim, Dong-Hyuk;Seon, Jong-In;Kang, Jung-Won;Nam, Dong-Woo;Lee, Seung-Deok;Choi, Do-Young;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.1-16
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the effects of manual acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ on Electroencephalogram(EEG) of patients with stroke. Methods : 32 channel EEG measurement was carried out in 35 Stroke patients(23 males and 12 females). EEG was measured for 21 minutes(made up of 7 sessions, 1 session means 3 minutes time interval) including 15 minutes(5 sessions) of acupuncture time. Power spectrum analysis was used as a measure of complexity. Statistical analysis was performed using Linear mixed model and DUNNETT's multiple comparison. Results : The results were as follows; 1. EEG amplitude was reduced during acupuncture except electrodes PG1 and PG2. 2. There was a notable change during 6~9 minutes after needling in ${\delta}{\cdot}{\beta}{\cdot}{\gamma}$ wave, and during 6~9 minutes after needling in ${\Theta}{\cdot}{\alpha}$ wave. Overall, during 6~9 minutes after needling. 3. TP8 is a common significant electrode among five wave forms. Conclusions : These results suggest that TP8 could be typical electrodes and change of EEG compared to baseline happens most often during 6~9 minutes after manipulated acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ of patients with stroke.

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF

Molecular Conductance Switching Processes through Single Ruthenium Complex Molecules in Self-Assembled Monolayers

  • Seo, So-Hyeon;Lee, Jeong-Hyeon;Bang, Gyeong-Suk;Lee, Hyo-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.27-27
    • /
    • 2011
  • For the design of real applicable molecular devices, current-voltage properties through molecular nanostructures such as metal-molecule-metal junctions (molecular junctions) have been studied extensively. In thiolate monolayers on the gold electrode, the chemical bonding of sulfur to gold and the van der Waals interactions between the alkyl chains of neighboring molecules are important factors in the formation of well-defined monolayers and in the control of the electron transport rate. Charge transport through the molecular junctions depends significantly on the energy levels of molecules relative to the Fermi levels of the contacts and the electronic structure of the molecule. It is important to understand the interfacial electron transport in accordance with the increased film thickness of alkyl chains that are known as an insulating layer, but are required for molecular device fabrication. Thiol-tethered RuII terpyridine complexes were synthesized for a voltage-driven molecular switch and used to understand the switch-on mechanism of the molecular switches of single metal complexes in the solid-state molecular junction in a vacuum. Electrochemical voltammetry and current-voltage (I-V) characteristics are measured to elucidate electron transport processes in the bistable conducting states of single molecular junctions of a molecular switch, Ru(II) terpyridine complexes. (1) On the basis of the Ru-centered electrochemical reaction data, the electron transport rate increases in the mixed self-assembled monolayer (SAM) of Ru(II) terpyridine complexes, indicating strong electronic coupling between the redox center and the substrate, along the molecules. (2) In a low-conducting state before switch-on, I-V characteristics are fitted to a direct tunneling model, and the estimated tunneling decay constant across the Ru(II) terpyridine complex is found to be smaller than that of alkanethiol. (3) The threshold voltages for the switch-on from low- to high-conducting states are identical, corresponding to the electron affinity of the molecules. (4) A high-conducting state after switch-on remains in the reverse voltage sweep, and a linear relationship of the current to the voltage is obtained. These results reveal electron transport paths via the redox centers of the Ru(II) terpyridine complexes, a molecular switch.

  • PDF

Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods (비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The aim of this study is to develop a label-free immunosensor for microbial detection and to evaluate its applicability to Pseudomonas aeruginosa detection in various food samples. The antibodies used were a polyclonal antiserum from rabbit (polyvalent type) and a monoclonal antibody raised against the flagella of P. aeruginosa. Antibody immobilization was done by a thiolated antibody chemisorption onto one gold electrode of a piezoelectric quartz crystal with a thiol-cleavable, heterobifunctional cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. To the Stomacher-treated samples from various raw and processed foods under cold storage, comprising sirloin, cod and pettitoes, spiking and enrichment culture were done to prepare the model samples, followed by the measurements of the frequency shifts after sample injections. The frequency shifts obtained by the sample matrices themselves were in the range of 52~89 Hz. The injections of the spiked samples caused the frequency shifts of 108~200 Hz, whereas the enriched samples decreased the steady-state resonant frequencies by 162~222 Hz. All sample measurements including baseline stabilization, sample injection and acquisition of the steady-state response were accomplished within 30 min.