• Title/Summary/Keyword: Electrode Fatigue

Search Result 74, Processing Time 0.028 seconds

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

Device Characteristics of MFSFET with the Fatigue of the Ferroelectric Thin Film (강유전박막의 피로현상을 고려한 MFSFET 소자의 특성)

  • 이국표;강성준;윤영섭
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.191-194
    • /
    • 1999
  • Switching behaviour of the ferroelectric thin film and device characteristics of the MFSFET (Metal-Ferroelectric-Semiconductor FET) are simulated with taking into account the accumulation of oxygen vacancies near interface between the ferroelectric thin film and the bottom electrode caused by the progress of fatigue. We show net switching current decreases due fatigue in the switching model. It indicates that oxygen vacancy strongly suppresses polarization reversal. The difference of saturation drain current of the device before fatigue is shown by the dual threshold voltages in I$_{D}$-V$_{D}$ curve as 6㎃/$\textrm{cm}^2$ and decreases as much as 50% after fatigue. Our simulation model is expected to play an important role in estimation of the behavior of MFSFET device with various ferroelectric thin films.lms.

  • PDF

A study on the corrosion fatigue and cathodic protection of the welded zone between high tensile strength steel and general strength steel used for the shipbuilding (조선용 고장력강재와 보통강도강재간의 용접부위의 부식피로와 전기방식에 관한 연구)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.39-50
    • /
    • 1984
  • The plane bending corrosion fatigue test was performed on the welded zone between SM58 steel plate and SM41 steel plate jointed with submerged arc welding in the air and in the natural sea water with various conditions. The main results obtained from the test are summarized as follows: 1) The welded zone of the steel plates has the lowest impact strength and the highest electrode potential, but the hardness was mediate of SM58 base and SM41 base. 2) The cathodic protection of the welded zone was also effective for the plane bending corrosion fatigue, and the optimum protection potential of the welded zone was -1,000 mV SCE. 3) The corrosion fatigue strength under the various stress conditions of the steel plate could be estimated and also the require safety factors on the design could be obtained from the plane bending fatigue limit diagram.

  • PDF

Development of Accurate Bevel Gear Die (정밀 베벨 기어 금형개발)

  • 이광오;진민호;제진수;강성수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.43-46
    • /
    • 2003
  • To develop bevel gear dies that have characteristics of high precision and enough life time, the technology of die manufacturing and design which increase the resistance of wear and fatigue is essentially needed. Here in the study, we have investigated several materials for dies and electrode. And, the most economical and suitable electrode material has been selected through the characteristic analysis of electrode materials such as copper, graphite and chromium copper. With the help of CAD/CAM/CAE, the total manufacturing system of high precision electrode for bevel gear has been established.

  • PDF

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • Park, No-Chang;Hong, Won-Sik;Han, Chang-Un;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF

Study on the Corrosion Fatigue Crack Propagation Behavior of Steel Used for Frame of Vehicles in Marine Environment (해양환경중에서 자동차 프레임용 강재의 부식피로균열전파거동에 관한 연구)

  • 이상열;임종문;이종악
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.76-84
    • /
    • 1992
  • In this study, corrosion fatigue test of SAPH45 steel was performed by the use of plane behavior of base metal (BM) and heat affected zone (HAZ) of SAPH45. The main results obtained are as follows: 1) The more aspect ratio (b/t) of corner crack decreases, the more aspect ratio (b/a) takes greatly effect by corrosion. 2) The correlation between the stress intensity factor range ($\Delta$k) and crack growth rate (da/dN) for weldment in seawater is given by Paris rule as follow: da/dN=C($\Delta$K) super(m). Where m is constant, and the value is 3.82-3.84. 3) The accelerative factor ($\alpha$) of BM and HAZ under seawater is about 1.1-1.9, and ($\alpha$) of HAZ increases more and more under the low $\Delta$K region. 4) HAZ is more susceptible to corrowion than BM because of potential of electrode (E sub(c)) of HAZ becomes more less noble potential than that of BM.

  • PDF

Properties of PZI Thin film on the Ru/RuO2 Electrode (Ru/RuO2전극에 성장한 PZT 박막의 특성에 관한 연구)

  • Kang, Hyun-Il;Choi, Jang-Hyun;Park, Young;Song, Joon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.865-869
    • /
    • 2002
  • The structural and electrical properties of PZT (lead zirconate titante) thin films grown on Pt (platinum) and Ru/Ru $O_2$(ruthenium/ruthenium oxide) electrodes were investigated. Thin films of PZT were deposited on a variety of electrodes using the rf-magnetron sputtering process. PZT films exhibited polycrystalline structure with strong PZT (100) plane and weak (211) plane for an optimizied Pt electrode and (100), (101), (111), (200), (210), (211) planes for Ru/Ru $O_2$. Switching polarization versus fatigue characteristic of Pt/Ti electrodes showed 20% degradation up to 1 $\times$ 10$_{9}$ cycles. No significant fatigue was observed in the films on Ru/Ru $O_2$ electrodes up to Ix109 test cycles. The results show that the new Ru/Ru $O_2$ bottom electrodes are expected to reduce the degradation of ferroelectric fatigue.

Effects of Change in the Height of Therapy Tables on the Fatigue of Splenius Capitis Muscle and Trapezius Muscle

  • Kim, Young Hoon;Noh, Ji Bin;Joo, Sung Hoon;Choi, Jung Hyun;Yoon, Jung Gyu;Lee, Sang Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.1
    • /
    • pp.516-522
    • /
    • 2013
  • The purpose of this study is to analysis of muscle fatigue in the upper trapezius and splenius capitis muscles according to therapy table height variation. The subjects were consisted of 15 healthy adults(10 males, 5 females) who had no medical history of neurological and musculoskeletal problems. In experiment, wireless electrode EMG system was measured for each the upper trapezius and splenius capitis muscles during the treatment performed on table. the differences in the muscle fatigue was compared for 4 types of table height(-6cm, -3cm, 0, +3cm from elbow in $90^{\circ}$ flexion position). Muscle fatigue according to therapy table height were significant difference except for left upper trapezius. And muscle fatigue of right upper trapezius and splenius capitis showed significant decrease in +3cm table height compared to -6cm table height(p<.05). Muscle fatigue of right upper trapezius and splenius capitis were the highest in -6cm table height, but those were the lowest in +3cm table height. This study propose to change therapy table height higher than +3cm from elbow in $90^{\circ}$ flexion position, if you hope to reduce muscle fatigue.

Real Time Implementittion of Time Varying Nonstationary Signal Identifier and Its Application to Muscle Fatigue Monitoring (비정상 시변 신호 인식기의 실시간 구현 및 근피로도 측정에의 응용)

  • Lee, Jin;Lee, Young-Seock;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.317-324
    • /
    • 1995
  • A need exists for the accurate identification of time series models having time varying parameters, as is important in the case of real time identification of nonstationary EMG signal. Thls paper describes real time identification and muscle fatigue monitoring method of nonstationary EMG signal. The method is composed of the efficient identifier which estimates the autoregressive parameters of nonstationary EMG signal model, and its real time implementation by using T805 parallel processing computer. The method is verified through experiment with real EMG signals which are obtained from surface electrode. As a result, the proposed method provides a new approach for real time Implementation of muscle fatigue monitoring and the execution time is 0.894ms/sample for 1024Hz EMG signal.

  • PDF

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF